Cargando…
3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye
BACKGROUND: Advances in MRI coil technology and increased availability of high-field MRI in veterinary medicine enable the acquisition of images of increasingly high spatial resolution while preserving signal-to-noise ratio.The purpose of the present study was to compare 3T high-resolution magnetic...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8829979/ https://www.ncbi.nlm.nih.gov/pubmed/35144606 http://dx.doi.org/10.1186/s12917-021-03108-0 |
Sumario: | BACKGROUND: Advances in MRI coil technology and increased availability of high-field MRI in veterinary medicine enable the acquisition of images of increasingly high spatial resolution while preserving signal-to-noise ratio.The purpose of the present study was to compare 3T high-resolution magnetic resonance imaging (HR-MRI) with ultrasound (US) and ultrasound biomicroscopy (UBM) in the normal canine eye, to assess its potential to depict normal ocular anatomy. RESULTS: HR-MRI was compared with US and UBM in 10 eyes from 10 healthy beagle dogs. Ocular structures (cornea, anterior chamber, iridocorneal angle, iris, lens, ciliary body, choroid, vitreous body, posterior wall of the eye, optic nerve and optic nerve sheath, extraocular muscles) were assessed subjectively and central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), anteroposterior, mediolateral and dorsoventral lens diameter (APLD, MLLD, DVLD), anteroposterior diameter of the globe including and excluding the scleroretinal rim (APDSRR, APD), vitreous chamber depth (VCD) and optic nerve sheath diameter (ONSD) were measured in HR-MRI and in US. Optic nerve diameter (OND) was measured in HR-MRI. HR-MRI and UBM appearance of the anterior segment were subjectively compared. Detailed reference high-resolution MRI images of normal eyes of Beagle dogs are provided. CONCLUSIONS: HR-MRI allowed assessment of all structures identified with US and UBM. The MRI examinations were performed under general anesthesia with the addition of a neuromuscular blocking agent, while US and UBM examinations were performed in conscious animals. Visibility of the entire ocular wall, the lens, the structures caudal to the ciliary body and the optic nerve and its sheath was superior with HR-MRI. HR-MRI allowed the distinction of retina, choroid and sclera, and the delineation of structures not previously identified in canine eyes with MRI, including Tenon’s capsule and the sub-Tenon’s space.Plane selection was more accurate with HR-MRI compared to US. In general, the range of measurements was narrower for MRI than for US. CCT, AQD, APLD, MLLD, APD, APDSRR and ONSD differed significantly between HR-MRI and US, respectively (p = 0.005-0.027).Micro-MRI may be useful for the assessment of ocular pathologies in the future. |
---|