Cargando…
3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye
BACKGROUND: Advances in MRI coil technology and increased availability of high-field MRI in veterinary medicine enable the acquisition of images of increasingly high spatial resolution while preserving signal-to-noise ratio.The purpose of the present study was to compare 3T high-resolution magnetic...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8829979/ https://www.ncbi.nlm.nih.gov/pubmed/35144606 http://dx.doi.org/10.1186/s12917-021-03108-0 |
_version_ | 1784648181139636224 |
---|---|
author | Ivan, Daniel Ohlerth, Stefanie Richter, Henning Verdino, Dagmar Rampazzo, Antonella Pot, Simon |
author_facet | Ivan, Daniel Ohlerth, Stefanie Richter, Henning Verdino, Dagmar Rampazzo, Antonella Pot, Simon |
author_sort | Ivan, Daniel |
collection | PubMed |
description | BACKGROUND: Advances in MRI coil technology and increased availability of high-field MRI in veterinary medicine enable the acquisition of images of increasingly high spatial resolution while preserving signal-to-noise ratio.The purpose of the present study was to compare 3T high-resolution magnetic resonance imaging (HR-MRI) with ultrasound (US) and ultrasound biomicroscopy (UBM) in the normal canine eye, to assess its potential to depict normal ocular anatomy. RESULTS: HR-MRI was compared with US and UBM in 10 eyes from 10 healthy beagle dogs. Ocular structures (cornea, anterior chamber, iridocorneal angle, iris, lens, ciliary body, choroid, vitreous body, posterior wall of the eye, optic nerve and optic nerve sheath, extraocular muscles) were assessed subjectively and central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), anteroposterior, mediolateral and dorsoventral lens diameter (APLD, MLLD, DVLD), anteroposterior diameter of the globe including and excluding the scleroretinal rim (APDSRR, APD), vitreous chamber depth (VCD) and optic nerve sheath diameter (ONSD) were measured in HR-MRI and in US. Optic nerve diameter (OND) was measured in HR-MRI. HR-MRI and UBM appearance of the anterior segment were subjectively compared. Detailed reference high-resolution MRI images of normal eyes of Beagle dogs are provided. CONCLUSIONS: HR-MRI allowed assessment of all structures identified with US and UBM. The MRI examinations were performed under general anesthesia with the addition of a neuromuscular blocking agent, while US and UBM examinations were performed in conscious animals. Visibility of the entire ocular wall, the lens, the structures caudal to the ciliary body and the optic nerve and its sheath was superior with HR-MRI. HR-MRI allowed the distinction of retina, choroid and sclera, and the delineation of structures not previously identified in canine eyes with MRI, including Tenon’s capsule and the sub-Tenon’s space.Plane selection was more accurate with HR-MRI compared to US. In general, the range of measurements was narrower for MRI than for US. CCT, AQD, APLD, MLLD, APD, APDSRR and ONSD differed significantly between HR-MRI and US, respectively (p = 0.005-0.027).Micro-MRI may be useful for the assessment of ocular pathologies in the future. |
format | Online Article Text |
id | pubmed-8829979 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-88299792022-02-10 3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye Ivan, Daniel Ohlerth, Stefanie Richter, Henning Verdino, Dagmar Rampazzo, Antonella Pot, Simon BMC Vet Res Research BACKGROUND: Advances in MRI coil technology and increased availability of high-field MRI in veterinary medicine enable the acquisition of images of increasingly high spatial resolution while preserving signal-to-noise ratio.The purpose of the present study was to compare 3T high-resolution magnetic resonance imaging (HR-MRI) with ultrasound (US) and ultrasound biomicroscopy (UBM) in the normal canine eye, to assess its potential to depict normal ocular anatomy. RESULTS: HR-MRI was compared with US and UBM in 10 eyes from 10 healthy beagle dogs. Ocular structures (cornea, anterior chamber, iridocorneal angle, iris, lens, ciliary body, choroid, vitreous body, posterior wall of the eye, optic nerve and optic nerve sheath, extraocular muscles) were assessed subjectively and central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), anteroposterior, mediolateral and dorsoventral lens diameter (APLD, MLLD, DVLD), anteroposterior diameter of the globe including and excluding the scleroretinal rim (APDSRR, APD), vitreous chamber depth (VCD) and optic nerve sheath diameter (ONSD) were measured in HR-MRI and in US. Optic nerve diameter (OND) was measured in HR-MRI. HR-MRI and UBM appearance of the anterior segment were subjectively compared. Detailed reference high-resolution MRI images of normal eyes of Beagle dogs are provided. CONCLUSIONS: HR-MRI allowed assessment of all structures identified with US and UBM. The MRI examinations were performed under general anesthesia with the addition of a neuromuscular blocking agent, while US and UBM examinations were performed in conscious animals. Visibility of the entire ocular wall, the lens, the structures caudal to the ciliary body and the optic nerve and its sheath was superior with HR-MRI. HR-MRI allowed the distinction of retina, choroid and sclera, and the delineation of structures not previously identified in canine eyes with MRI, including Tenon’s capsule and the sub-Tenon’s space.Plane selection was more accurate with HR-MRI compared to US. In general, the range of measurements was narrower for MRI than for US. CCT, AQD, APLD, MLLD, APD, APDSRR and ONSD differed significantly between HR-MRI and US, respectively (p = 0.005-0.027).Micro-MRI may be useful for the assessment of ocular pathologies in the future. BioMed Central 2022-02-10 /pmc/articles/PMC8829979/ /pubmed/35144606 http://dx.doi.org/10.1186/s12917-021-03108-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visithttp://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ivan, Daniel Ohlerth, Stefanie Richter, Henning Verdino, Dagmar Rampazzo, Antonella Pot, Simon 3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye |
title | 3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye |
title_full | 3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye |
title_fullStr | 3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye |
title_full_unstemmed | 3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye |
title_short | 3T high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye |
title_sort | 3t high-resolution magnetic resonance imaging, conventional ultrasonography and ultrasound biomicroscopy of the normal canine eye |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8829979/ https://www.ncbi.nlm.nih.gov/pubmed/35144606 http://dx.doi.org/10.1186/s12917-021-03108-0 |
work_keys_str_mv | AT ivandaniel 3thighresolutionmagneticresonanceimagingconventionalultrasonographyandultrasoundbiomicroscopyofthenormalcanineeye AT ohlerthstefanie 3thighresolutionmagneticresonanceimagingconventionalultrasonographyandultrasoundbiomicroscopyofthenormalcanineeye AT richterhenning 3thighresolutionmagneticresonanceimagingconventionalultrasonographyandultrasoundbiomicroscopyofthenormalcanineeye AT verdinodagmar 3thighresolutionmagneticresonanceimagingconventionalultrasonographyandultrasoundbiomicroscopyofthenormalcanineeye AT rampazzoantonella 3thighresolutionmagneticresonanceimagingconventionalultrasonographyandultrasoundbiomicroscopyofthenormalcanineeye AT potsimon 3thighresolutionmagneticresonanceimagingconventionalultrasonographyandultrasoundbiomicroscopyofthenormalcanineeye |