Cargando…
Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis
BACKGROUND/AIMS: Multiple outbreaks of multidrug-resistant organisms have been reported worldwide due to contaminated duodenoscopes. In 2015, the United States Food and Drug Administration recommended the following supplemental enhanced surveillance and reprocessing techniques (ESRT) to improve duod...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Gastrointestinal Endoscopy
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8831410/ https://www.ncbi.nlm.nih.gov/pubmed/34974676 http://dx.doi.org/10.5946/ce.2021.212 |
_version_ | 1784648503206608896 |
---|---|
author | Bomman, Shivanand Ashat, Munish Nagra, Navroop Jayaraj, Mahendran Chandra, Shruti Kozarek, Richard A Ross, Andrew Krishnamoorthi, Rajesh |
author_facet | Bomman, Shivanand Ashat, Munish Nagra, Navroop Jayaraj, Mahendran Chandra, Shruti Kozarek, Richard A Ross, Andrew Krishnamoorthi, Rajesh |
author_sort | Bomman, Shivanand |
collection | PubMed |
description | BACKGROUND/AIMS: Multiple outbreaks of multidrug-resistant organisms have been reported worldwide due to contaminated duodenoscopes. In 2015, the United States Food and Drug Administration recommended the following supplemental enhanced surveillance and reprocessing techniques (ESRT) to improve duodenoscope disinfection: (1) microbiological culture, (2) ethylene oxide sterilization, (3) liquid chemical sterilant processing system, and (4) double high-level disinfection. A systematic review and meta-analysis was performed to assess the impact of ESRT on the contamination rates. METHODS: A thorough and systematic search was performed across several databases and conference proceedings from inception until January 2021, and all studies reporting the effectiveness of various ESRTs were identified. The pooled contamination rates of post-ESRT duodenoscopes were estimated using the random effects model. RESULTS: A total of seven studies using various ESRTs were incorporated in the analysis, which included a total of 9,084 post-ESRT duodenoscope cultures. The pooled contamination rate of the post-ESRT duodenoscope was 5% (95% confidence interval [CI]: 2.3%–10.8%, inconsistency index [I(2)]=97.97%). Pooled contamination rates for high-risk organisms were 0.8% (95% CI: 0.2%–2.7%, I(2)=94.96). CONCLUSIONS: While ESRT may improve the disinfection process, a post-ESRT contamination rate of 5% is not negligible. Ongoing efforts to mitigate the rate of contamination by improving disinfection techniques and innovations in duodenoscope design to improve safety are warranted. |
format | Online Article Text |
id | pubmed-8831410 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Society of Gastrointestinal Endoscopy |
record_format | MEDLINE/PubMed |
spelling | pubmed-88314102022-02-22 Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis Bomman, Shivanand Ashat, Munish Nagra, Navroop Jayaraj, Mahendran Chandra, Shruti Kozarek, Richard A Ross, Andrew Krishnamoorthi, Rajesh Clin Endosc Systematic Review and Meta-Analysis BACKGROUND/AIMS: Multiple outbreaks of multidrug-resistant organisms have been reported worldwide due to contaminated duodenoscopes. In 2015, the United States Food and Drug Administration recommended the following supplemental enhanced surveillance and reprocessing techniques (ESRT) to improve duodenoscope disinfection: (1) microbiological culture, (2) ethylene oxide sterilization, (3) liquid chemical sterilant processing system, and (4) double high-level disinfection. A systematic review and meta-analysis was performed to assess the impact of ESRT on the contamination rates. METHODS: A thorough and systematic search was performed across several databases and conference proceedings from inception until January 2021, and all studies reporting the effectiveness of various ESRTs were identified. The pooled contamination rates of post-ESRT duodenoscopes were estimated using the random effects model. RESULTS: A total of seven studies using various ESRTs were incorporated in the analysis, which included a total of 9,084 post-ESRT duodenoscope cultures. The pooled contamination rate of the post-ESRT duodenoscope was 5% (95% confidence interval [CI]: 2.3%–10.8%, inconsistency index [I(2)]=97.97%). Pooled contamination rates for high-risk organisms were 0.8% (95% CI: 0.2%–2.7%, I(2)=94.96). CONCLUSIONS: While ESRT may improve the disinfection process, a post-ESRT contamination rate of 5% is not negligible. Ongoing efforts to mitigate the rate of contamination by improving disinfection techniques and innovations in duodenoscope design to improve safety are warranted. Korean Society of Gastrointestinal Endoscopy 2022-01 2022-01-03 /pmc/articles/PMC8831410/ /pubmed/34974676 http://dx.doi.org/10.5946/ce.2021.212 Text en Copyright © 2022 Korean Society of Gastrointestinal Endoscopy https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Systematic Review and Meta-Analysis Bomman, Shivanand Ashat, Munish Nagra, Navroop Jayaraj, Mahendran Chandra, Shruti Kozarek, Richard A Ross, Andrew Krishnamoorthi, Rajesh Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis |
title | Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis |
title_full | Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis |
title_fullStr | Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis |
title_short | Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis |
title_sort | contamination rates in duodenoscopes reprocessed using enhanced surveillance and reprocessing techniques: a systematic review and meta-analysis |
topic | Systematic Review and Meta-Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8831410/ https://www.ncbi.nlm.nih.gov/pubmed/34974676 http://dx.doi.org/10.5946/ce.2021.212 |
work_keys_str_mv | AT bommanshivanand contaminationratesinduodenoscopesreprocessedusingenhancedsurveillanceandreprocessingtechniquesasystematicreviewandmetaanalysis AT ashatmunish contaminationratesinduodenoscopesreprocessedusingenhancedsurveillanceandreprocessingtechniquesasystematicreviewandmetaanalysis AT nagranavroop contaminationratesinduodenoscopesreprocessedusingenhancedsurveillanceandreprocessingtechniquesasystematicreviewandmetaanalysis AT jayarajmahendran contaminationratesinduodenoscopesreprocessedusingenhancedsurveillanceandreprocessingtechniquesasystematicreviewandmetaanalysis AT chandrashruti contaminationratesinduodenoscopesreprocessedusingenhancedsurveillanceandreprocessingtechniquesasystematicreviewandmetaanalysis AT kozarekricharda contaminationratesinduodenoscopesreprocessedusingenhancedsurveillanceandreprocessingtechniquesasystematicreviewandmetaanalysis AT rossandrew contaminationratesinduodenoscopesreprocessedusingenhancedsurveillanceandreprocessingtechniquesasystematicreviewandmetaanalysis AT krishnamoorthirajesh contaminationratesinduodenoscopesreprocessedusingenhancedsurveillanceandreprocessingtechniquesasystematicreviewandmetaanalysis |