Cargando…
Watchman Device Procedure Complicated by Rare Perclose ProGlide Embolization: Case Report and Literature Review
Atrial fibrillation (AF) is the most common cardiac arrhythmia with significant morbidity and mortality. In this case, we present a 69-year-old man with a past medical history of atrial fibrillation on warfarin who came to the hospital for placement of the Watchman device (Boston Scientific Corporat...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8831485/ https://www.ncbi.nlm.nih.gov/pubmed/35165622 http://dx.doi.org/10.7759/cureus.21173 |
_version_ | 1784648514465169408 |
---|---|
author | Beshai, Rafail |
author_facet | Beshai, Rafail |
author_sort | Beshai, Rafail |
collection | PubMed |
description | Atrial fibrillation (AF) is the most common cardiac arrhythmia with significant morbidity and mortality. In this case, we present a 69-year-old man with a past medical history of atrial fibrillation on warfarin who came to the hospital for placement of the Watchman device (Boston Scientific Corporation, Marlborough, Massachusetts, United States). His procedure was complicated by Perclose ProGlide™ Suture-Mediated Closure system (Abbott Laboratories Inc., Chicago, Illinois, United States) embolism. The vascular surgery department was consulted STAT in the electrophysiology lab and was unable to fully visualize the vessel. The patient was then brought emergently to a hybrid operating room where venotomy was made. He tolerated the procedure well and was eventually discharged home. |
format | Online Article Text |
id | pubmed-8831485 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-88314852022-02-13 Watchman Device Procedure Complicated by Rare Perclose ProGlide Embolization: Case Report and Literature Review Beshai, Rafail Cureus Cardiology Atrial fibrillation (AF) is the most common cardiac arrhythmia with significant morbidity and mortality. In this case, we present a 69-year-old man with a past medical history of atrial fibrillation on warfarin who came to the hospital for placement of the Watchman device (Boston Scientific Corporation, Marlborough, Massachusetts, United States). His procedure was complicated by Perclose ProGlide™ Suture-Mediated Closure system (Abbott Laboratories Inc., Chicago, Illinois, United States) embolism. The vascular surgery department was consulted STAT in the electrophysiology lab and was unable to fully visualize the vessel. The patient was then brought emergently to a hybrid operating room where venotomy was made. He tolerated the procedure well and was eventually discharged home. Cureus 2022-01-12 /pmc/articles/PMC8831485/ /pubmed/35165622 http://dx.doi.org/10.7759/cureus.21173 Text en Copyright © 2022, Beshai et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Cardiology Beshai, Rafail Watchman Device Procedure Complicated by Rare Perclose ProGlide Embolization: Case Report and Literature Review |
title | Watchman Device Procedure Complicated by Rare Perclose ProGlide Embolization: Case Report and Literature Review |
title_full | Watchman Device Procedure Complicated by Rare Perclose ProGlide Embolization: Case Report and Literature Review |
title_fullStr | Watchman Device Procedure Complicated by Rare Perclose ProGlide Embolization: Case Report and Literature Review |
title_full_unstemmed | Watchman Device Procedure Complicated by Rare Perclose ProGlide Embolization: Case Report and Literature Review |
title_short | Watchman Device Procedure Complicated by Rare Perclose ProGlide Embolization: Case Report and Literature Review |
title_sort | watchman device procedure complicated by rare perclose proglide embolization: case report and literature review |
topic | Cardiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8831485/ https://www.ncbi.nlm.nih.gov/pubmed/35165622 http://dx.doi.org/10.7759/cureus.21173 |
work_keys_str_mv | AT beshairafail watchmandeviceprocedurecomplicatedbyrarepercloseproglideembolizationcasereportandliteraturereview |