Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer
A lens-based Raman spectrometer is characterized by studying the optical elements in the optical path and we study the measure of aberration–diffraction effects. This is achieved by measuring the spectral resolution (SR) thus encompassing almost all optical elements of a spectrometer that are mostly...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8832553/ https://www.ncbi.nlm.nih.gov/pubmed/34643132 http://dx.doi.org/10.1177/00037028211055148 |
_version_ | 1784648744400060416 |
---|---|
author | Mukherjee, Ashutosh Lorenz, Anita Brecht, Marc |
author_facet | Mukherjee, Ashutosh Lorenz, Anita Brecht, Marc |
author_sort | Mukherjee, Ashutosh |
collection | PubMed |
description | A lens-based Raman spectrometer is characterized by studying the optical elements in the optical path and we study the measure of aberration–diffraction effects. This is achieved by measuring the spectral resolution (SR) thus encompassing almost all optical elements of a spectrometer that are mostly responsible for such effects. An equation for SR is used to determine the quality factor Q which measures aberration/diffraction effects occurring in a spectrometer. We show how the quality factor changes with different spectrometer parameters such as grating groove density, the wavelength of excitation, pinhole width, charge-coupled device (CCD) pixel density, etc. This work provides an insight into the quality of a spectrometer and helps to monitor the performance of the spectrometer over a certain period. Commercially available spectrometers or home-built spectrometers are prone to misalignment in optical elements and can benefit from this work that allows maintaining the overall quality of the setup. Performing such experiments over a period helps to minimize the aberration/diffraction effects occurring as a result of time and maintaining the quality of measurements. |
format | Online Article Text |
id | pubmed-8832553 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-88325532022-02-12 Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer Mukherjee, Ashutosh Lorenz, Anita Brecht, Marc Appl Spectrosc Submitted Papers A lens-based Raman spectrometer is characterized by studying the optical elements in the optical path and we study the measure of aberration–diffraction effects. This is achieved by measuring the spectral resolution (SR) thus encompassing almost all optical elements of a spectrometer that are mostly responsible for such effects. An equation for SR is used to determine the quality factor Q which measures aberration/diffraction effects occurring in a spectrometer. We show how the quality factor changes with different spectrometer parameters such as grating groove density, the wavelength of excitation, pinhole width, charge-coupled device (CCD) pixel density, etc. This work provides an insight into the quality of a spectrometer and helps to monitor the performance of the spectrometer over a certain period. Commercially available spectrometers or home-built spectrometers are prone to misalignment in optical elements and can benefit from this work that allows maintaining the overall quality of the setup. Performing such experiments over a period helps to minimize the aberration/diffraction effects occurring as a result of time and maintaining the quality of measurements. SAGE Publications 2021-10-29 2022-02 /pmc/articles/PMC8832553/ /pubmed/34643132 http://dx.doi.org/10.1177/00037028211055148 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Submitted Papers Mukherjee, Ashutosh Lorenz, Anita Brecht, Marc Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer |
title | Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer |
title_full | Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer |
title_fullStr | Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer |
title_full_unstemmed | Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer |
title_short | Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer |
title_sort | determination and monitoring of quality parameters: a detailed study of optical elements of a lens-based raman spectrometer |
topic | Submitted Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8832553/ https://www.ncbi.nlm.nih.gov/pubmed/34643132 http://dx.doi.org/10.1177/00037028211055148 |
work_keys_str_mv | AT mukherjeeashutosh determinationandmonitoringofqualityparametersadetailedstudyofopticalelementsofalensbasedramanspectrometer AT lorenzanita determinationandmonitoringofqualityparametersadetailedstudyofopticalelementsofalensbasedramanspectrometer AT brechtmarc determinationandmonitoringofqualityparametersadetailedstudyofopticalelementsofalensbasedramanspectrometer |