Cargando…
A prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery
BACKGROUND: Robot-assisted open surgery (RA-OS) is now commonly used in traditional open-exposure spinal screw placement surgery. With the help of robots, robot-assisted minimally invasive surgery (RA-MIS) can achieve less bleeding and less tissue damage in percutaneous screw insertion. While the re...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8832639/ https://www.ncbi.nlm.nih.gov/pubmed/35148734 http://dx.doi.org/10.1186/s12893-022-01503-4 |
_version_ | 1784648764832612352 |
---|---|
author | Fan, Mingxing Fang, Yanming Zhang, Qi Zhao, Jingwei Liu, Bo Tian, Wei |
author_facet | Fan, Mingxing Fang, Yanming Zhang, Qi Zhao, Jingwei Liu, Bo Tian, Wei |
author_sort | Fan, Mingxing |
collection | PubMed |
description | BACKGROUND: Robot-assisted open surgery (RA-OS) is now commonly used in traditional open-exposure spinal screw placement surgery. With the help of robots, robot-assisted minimally invasive surgery (RA-MIS) can achieve less bleeding and less tissue damage in percutaneous screw insertion. While the research comparing the safety and accuracy of screw placement between RA-MIS and RA-OS is insufficient. This study aims to compare the effects of RA-MIS and RA-OS in thoracic and lumbar spine. METHODS: This was a prospective cohort study evaluating 208 patients undergoing robot-assisted screw insertions from July 2020 to September 2021. Age, BMI, gender, screws accuracy, screws Gertzbein–Robbins grade, small joint invasion and perioperative outcomes (operation time, blood loss, postoperative hospital stay, comorbidity) were collected. A subgroup analysis was also performed according to disease, namely fracture, spondylolisthesis, and disc herniation. Data were analyzed using Stata/MP 14.0. Wilcoxon’s signed rank test, Kruskal–Wallis test and Fisher’s exact test were used for statistical tests and p < 0.05 was considered statistically significant. RESULTS: A total of 1030 screws were inserted; 368 minimally invasive screws and 662 open screws. The acceptability of screw insertion in the RA-MIS and RA-OS was 97.3% and 95.6% respectively. There was no statistical difference between the RA-MIS group and RA-OS group in age (p = 0.106), gender (p = 0.074), BMI (p = 0.181) and comorbidity (p = 0.203). Compared with RA-OS, RA-MIS had less blood loss (p < 0.001) and shorter postoperative hospital stay (p = 0.008). In the minimally invasive surgery group, the fracture subgroup had smaller screw deviation, less blood loss, and shorter operation time compared with the other subgroups (p < 0.01). Specifically, RA-MIS significantly reduced the postoperative hospital stay of patients with spondylolisthesis compared with RA-OS (p < 0.01). CONCLUSION: RA-OS and RA-MIS had equal accuracy and safety. Compared with open surgery, minimally invasive surgery reduced blood loss in each subgroup and shortened the postoperative hospital stay in the spondylolisthesis subgroup. Compared with the other subgroups under minimally invasive surgery, the fracture subgroup had less blood loss and shorter operation time. Clinical trial registration: NCT04040868. Registered 1 March 2019, https://clinicaltrials.gov/ct2/show/NCT04040868?cond=Accuracy+Study+of+Robot-assisted+Screw+Insertion+in+Spinal+Surgery&draw=2&rank=1. |
format | Online Article Text |
id | pubmed-8832639 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-88326392022-02-11 A prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery Fan, Mingxing Fang, Yanming Zhang, Qi Zhao, Jingwei Liu, Bo Tian, Wei BMC Surg Research Article BACKGROUND: Robot-assisted open surgery (RA-OS) is now commonly used in traditional open-exposure spinal screw placement surgery. With the help of robots, robot-assisted minimally invasive surgery (RA-MIS) can achieve less bleeding and less tissue damage in percutaneous screw insertion. While the research comparing the safety and accuracy of screw placement between RA-MIS and RA-OS is insufficient. This study aims to compare the effects of RA-MIS and RA-OS in thoracic and lumbar spine. METHODS: This was a prospective cohort study evaluating 208 patients undergoing robot-assisted screw insertions from July 2020 to September 2021. Age, BMI, gender, screws accuracy, screws Gertzbein–Robbins grade, small joint invasion and perioperative outcomes (operation time, blood loss, postoperative hospital stay, comorbidity) were collected. A subgroup analysis was also performed according to disease, namely fracture, spondylolisthesis, and disc herniation. Data were analyzed using Stata/MP 14.0. Wilcoxon’s signed rank test, Kruskal–Wallis test and Fisher’s exact test were used for statistical tests and p < 0.05 was considered statistically significant. RESULTS: A total of 1030 screws were inserted; 368 minimally invasive screws and 662 open screws. The acceptability of screw insertion in the RA-MIS and RA-OS was 97.3% and 95.6% respectively. There was no statistical difference between the RA-MIS group and RA-OS group in age (p = 0.106), gender (p = 0.074), BMI (p = 0.181) and comorbidity (p = 0.203). Compared with RA-OS, RA-MIS had less blood loss (p < 0.001) and shorter postoperative hospital stay (p = 0.008). In the minimally invasive surgery group, the fracture subgroup had smaller screw deviation, less blood loss, and shorter operation time compared with the other subgroups (p < 0.01). Specifically, RA-MIS significantly reduced the postoperative hospital stay of patients with spondylolisthesis compared with RA-OS (p < 0.01). CONCLUSION: RA-OS and RA-MIS had equal accuracy and safety. Compared with open surgery, minimally invasive surgery reduced blood loss in each subgroup and shortened the postoperative hospital stay in the spondylolisthesis subgroup. Compared with the other subgroups under minimally invasive surgery, the fracture subgroup had less blood loss and shorter operation time. Clinical trial registration: NCT04040868. Registered 1 March 2019, https://clinicaltrials.gov/ct2/show/NCT04040868?cond=Accuracy+Study+of+Robot-assisted+Screw+Insertion+in+Spinal+Surgery&draw=2&rank=1. BioMed Central 2022-02-11 /pmc/articles/PMC8832639/ /pubmed/35148734 http://dx.doi.org/10.1186/s12893-022-01503-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Fan, Mingxing Fang, Yanming Zhang, Qi Zhao, Jingwei Liu, Bo Tian, Wei A prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery |
title | A prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery |
title_full | A prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery |
title_fullStr | A prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery |
title_full_unstemmed | A prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery |
title_short | A prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery |
title_sort | prospective cohort study of the accuracy and safety of robot-assisted minimally invasive spinal surgery |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8832639/ https://www.ncbi.nlm.nih.gov/pubmed/35148734 http://dx.doi.org/10.1186/s12893-022-01503-4 |
work_keys_str_mv | AT fanmingxing aprospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT fangyanming aprospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT zhangqi aprospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT zhaojingwei aprospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT liubo aprospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT tianwei aprospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT fanmingxing prospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT fangyanming prospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT zhangqi prospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT zhaojingwei prospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT liubo prospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery AT tianwei prospectivecohortstudyoftheaccuracyandsafetyofrobotassistedminimallyinvasivespinalsurgery |