Cargando…

Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system

INTRODUCTION: This study presents a comprehensive collision avoidance framework based on three‐dimension (3D) computer‐aided design (CAD) modeling, a graphical user interface (GUI) as peripheral to the radiation treatment planning (RTP) environment, and patient‐specific plan parameters for intensity...

Descripción completa

Detalles Bibliográficos
Autores principales: Dougherty, Jingjing M., Whitaker, Thomas J., Mundy, Daniel W., Tryggestad, Erik J., Beltran, Chris J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8833276/
https://www.ncbi.nlm.nih.gov/pubmed/34890094
http://dx.doi.org/10.1002/acm2.13496
_version_ 1784648896010518528
author Dougherty, Jingjing M.
Whitaker, Thomas J.
Mundy, Daniel W.
Tryggestad, Erik J.
Beltran, Chris J.
author_facet Dougherty, Jingjing M.
Whitaker, Thomas J.
Mundy, Daniel W.
Tryggestad, Erik J.
Beltran, Chris J.
author_sort Dougherty, Jingjing M.
collection PubMed
description INTRODUCTION: This study presents a comprehensive collision avoidance framework based on three‐dimension (3D) computer‐aided design (CAD) modeling, a graphical user interface (GUI) as peripheral to the radiation treatment planning (RTP) environment, and patient‐specific plan parameters for intensity‐modulated proton therapy (IMPT). METHODS: A stand‐alone software application was developed leveraging the Varian scripting application programming interface (API) for RTP database object accessibility. The Collision Avoider software models the Hitachi ProBeat‐V half gantry design and the Kuka robotic couch with triangle mesh structures. Patient‐specific plan parameters are displayed in the collision avoidance software for potential proximity evaluation. The external surfaces of the patients and the immobilization devices are contoured based on computed tomography (CT) images. A “table junction‐to‐CT‐origin” (JCT) measurement is made for every patient at the time of CT simulation to accurately provide reference location of the patient contours to the treatment couch. Collision evaluations were performed virtually with the program during treatment planning to prevent four major types of collisional events: collisions between the gantry head and the treatment couch, gantry head and the patient's body, gantry head and the robotic arm, and collisions between the gantry head and the immobilization devices. RESULTS: The Collision Avoider software was able to accurately model the proton treatment delivery system and the robotic couch position. Commonly employed clinical beam configuration and JCT values were investigated. Brain and head and neck patients require more complex gantry and patient positioning system configurations. Physical measurements were performed to validate 3D CAD model geometry. Twelve clinical proton treatment plans were used to validate the accuracy of the software. The software can predict all four types of collisional events in our clinic since its full implementation in 2020. CONCLUSION: A highly efficient patient‐specific collision prevention program for scanning proton therapy has been successfully implemented. The graphical program has provided accurate collision detection since its inception at our institution.
format Online
Article
Text
id pubmed-8833276
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-88332762022-02-14 Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system Dougherty, Jingjing M. Whitaker, Thomas J. Mundy, Daniel W. Tryggestad, Erik J. Beltran, Chris J. J Appl Clin Med Phys Radiation Oncology Physics INTRODUCTION: This study presents a comprehensive collision avoidance framework based on three‐dimension (3D) computer‐aided design (CAD) modeling, a graphical user interface (GUI) as peripheral to the radiation treatment planning (RTP) environment, and patient‐specific plan parameters for intensity‐modulated proton therapy (IMPT). METHODS: A stand‐alone software application was developed leveraging the Varian scripting application programming interface (API) for RTP database object accessibility. The Collision Avoider software models the Hitachi ProBeat‐V half gantry design and the Kuka robotic couch with triangle mesh structures. Patient‐specific plan parameters are displayed in the collision avoidance software for potential proximity evaluation. The external surfaces of the patients and the immobilization devices are contoured based on computed tomography (CT) images. A “table junction‐to‐CT‐origin” (JCT) measurement is made for every patient at the time of CT simulation to accurately provide reference location of the patient contours to the treatment couch. Collision evaluations were performed virtually with the program during treatment planning to prevent four major types of collisional events: collisions between the gantry head and the treatment couch, gantry head and the patient's body, gantry head and the robotic arm, and collisions between the gantry head and the immobilization devices. RESULTS: The Collision Avoider software was able to accurately model the proton treatment delivery system and the robotic couch position. Commonly employed clinical beam configuration and JCT values were investigated. Brain and head and neck patients require more complex gantry and patient positioning system configurations. Physical measurements were performed to validate 3D CAD model geometry. Twelve clinical proton treatment plans were used to validate the accuracy of the software. The software can predict all four types of collisional events in our clinic since its full implementation in 2020. CONCLUSION: A highly efficient patient‐specific collision prevention program for scanning proton therapy has been successfully implemented. The graphical program has provided accurate collision detection since its inception at our institution. John Wiley and Sons Inc. 2021-12-10 /pmc/articles/PMC8833276/ /pubmed/34890094 http://dx.doi.org/10.1002/acm2.13496 Text en © 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Dougherty, Jingjing M.
Whitaker, Thomas J.
Mundy, Daniel W.
Tryggestad, Erik J.
Beltran, Chris J.
Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system
title Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system
title_full Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system
title_fullStr Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system
title_full_unstemmed Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system
title_short Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system
title_sort design of a 3d patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8833276/
https://www.ncbi.nlm.nih.gov/pubmed/34890094
http://dx.doi.org/10.1002/acm2.13496
work_keys_str_mv AT doughertyjingjingm designofa3dpatientspecificcollisionavoidancevirtualframeworkforhalfgantryprotontherapysystem
AT whitakerthomasj designofa3dpatientspecificcollisionavoidancevirtualframeworkforhalfgantryprotontherapysystem
AT mundydanielw designofa3dpatientspecificcollisionavoidancevirtualframeworkforhalfgantryprotontherapysystem
AT tryggestaderikj designofa3dpatientspecificcollisionavoidancevirtualframeworkforhalfgantryprotontherapysystem
AT beltranchrisj designofa3dpatientspecificcollisionavoidancevirtualframeworkforhalfgantryprotontherapysystem