Cargando…
Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head
Titanium alloys are used in skeletal surgery. However, once bone union is complete, such fixation material becomes unnecessary or even harmful. Resorbable magnesium materials have been available for several years (WE43 alloy). The aim of this study was to clinically compare magnesium versus titanium...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8836973/ https://www.ncbi.nlm.nih.gov/pubmed/35160655 http://dx.doi.org/10.3390/ma15030711 |
_version_ | 1784649809291902976 |
---|---|
author | Kozakiewicz, Marcin Gabryelczak, Izabela Bielecki-Kowalski, Bartosz |
author_facet | Kozakiewicz, Marcin Gabryelczak, Izabela Bielecki-Kowalski, Bartosz |
author_sort | Kozakiewicz, Marcin |
collection | PubMed |
description | Titanium alloys are used in skeletal surgery. However, once bone union is complete, such fixation material becomes unnecessary or even harmful. Resorbable magnesium materials have been available for several years (WE43 alloy). The aim of this study was to clinically compare magnesium versus titanium open reduction and rigid fixations in mandible condylar heads. Ten patients were treated for fractures of the mandibular head with magnesium headless compression screws (2.3 mm in diameter), and 11 patients were included as a reference group with titanium screws (1.8 mm in diameter) with similar construction. The fixation characteristics (delay, time, and number of screws), distant anatomical results (mandibular ramus height loss, monthly loss rate, and relative loss of reconstructed ramus height), basic functional data (mandibular movements, facial nerve function, and cutaneous perception) and the influence of the effects of the injury (fracture type, fragmentation, occlusion, additional fractures, and associated diseases) on the outcome were evaluated. The long-term results of treatment were evaluated after 18 months. Treatment results similar to those of traditional titanium fixation were found with magnesium screws. Conclusions: Resorbable metal screws can be a favored option for osteosynthesis because surgical reentry can be avoided. These materials provide proper and stable treatment results. |
format | Online Article Text |
id | pubmed-8836973 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-88369732022-02-12 Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head Kozakiewicz, Marcin Gabryelczak, Izabela Bielecki-Kowalski, Bartosz Materials (Basel) Article Titanium alloys are used in skeletal surgery. However, once bone union is complete, such fixation material becomes unnecessary or even harmful. Resorbable magnesium materials have been available for several years (WE43 alloy). The aim of this study was to clinically compare magnesium versus titanium open reduction and rigid fixations in mandible condylar heads. Ten patients were treated for fractures of the mandibular head with magnesium headless compression screws (2.3 mm in diameter), and 11 patients were included as a reference group with titanium screws (1.8 mm in diameter) with similar construction. The fixation characteristics (delay, time, and number of screws), distant anatomical results (mandibular ramus height loss, monthly loss rate, and relative loss of reconstructed ramus height), basic functional data (mandibular movements, facial nerve function, and cutaneous perception) and the influence of the effects of the injury (fracture type, fragmentation, occlusion, additional fractures, and associated diseases) on the outcome were evaluated. The long-term results of treatment were evaluated after 18 months. Treatment results similar to those of traditional titanium fixation were found with magnesium screws. Conclusions: Resorbable metal screws can be a favored option for osteosynthesis because surgical reentry can be avoided. These materials provide proper and stable treatment results. MDPI 2022-01-18 /pmc/articles/PMC8836973/ /pubmed/35160655 http://dx.doi.org/10.3390/ma15030711 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kozakiewicz, Marcin Gabryelczak, Izabela Bielecki-Kowalski, Bartosz Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head |
title | Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head |
title_full | Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head |
title_fullStr | Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head |
title_full_unstemmed | Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head |
title_short | Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head |
title_sort | clinical evaluation of magnesium alloy osteosynthesis in the mandibular head |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8836973/ https://www.ncbi.nlm.nih.gov/pubmed/35160655 http://dx.doi.org/10.3390/ma15030711 |
work_keys_str_mv | AT kozakiewiczmarcin clinicalevaluationofmagnesiumalloyosteosynthesisinthemandibularhead AT gabryelczakizabela clinicalevaluationofmagnesiumalloyosteosynthesisinthemandibularhead AT bieleckikowalskibartosz clinicalevaluationofmagnesiumalloyosteosynthesisinthemandibularhead |