Cargando…
Detection of SARS-CoV-2 RNA in a conjunctival swab sample in real-time-polymerase chain reaction positive COVID-19 patients and its association with comorbidity and severity at a designated COVID-19 hospital in Central India
PURPOSE: To evaluate the presence of SARS-CoV-2 RNA in the conjunctival swab sample of positive confirmed COVID-19 patients and to find out its association with comorbidity and severity of COVID-19 disease. METHODS: We conducted an observational cross-sectional study at a dedicated tertiary COVID-19...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8837307/ https://www.ncbi.nlm.nih.gov/pubmed/34827010 http://dx.doi.org/10.4103/ijo.IJO_1604_21 |
_version_ | 1784649879310565376 |
---|---|
author | Chawhan, Anagha Athale, Ashish Khan, Khalid Agarwal, Saurabh Paul, Rajdeep Iyer, Karthik Khadia, Anjali Som, Vivek |
author_facet | Chawhan, Anagha Athale, Ashish Khan, Khalid Agarwal, Saurabh Paul, Rajdeep Iyer, Karthik Khadia, Anjali Som, Vivek |
author_sort | Chawhan, Anagha |
collection | PubMed |
description | PURPOSE: To evaluate the presence of SARS-CoV-2 RNA in the conjunctival swab sample of positive confirmed COVID-19 patients and to find out its association with comorbidity and severity of COVID-19 disease. METHODS: We conducted an observational cross-sectional study at a dedicated tertiary COVID-19 hospital in central India for a period of 8 weeks from February 2021to March 2021. We included patients who tested positive for SARS-CoV-2 RNA through nasopharyngeal swab and were above 18 years of age. Swab samples have been collected within 48 h of admission. Conjunctival swab was taken from the lower fornix of both eyes and sent to microbiology laboratory for real-time- polymerase chain reaction (RT-PCR). RESULTS: Out of 150 patients, conjunctival swab RT-PCR was positive in five patients (3.33%). Two patients had conjunctival manifestations in the form of conjunctivitis but conjunctival swab RT-PCR was negative in those patients. Among the RT-PCR positive patients, two (40%) were from mild, one (20%) was from moderate, and two (40%) were from severe category. No association could be established between conjunctival swab RT-PCR positivity and severity of the disease or associated comorbidity. CONCLUSION: Our study provides evidence that SARS-CoV-2 RNA could be detected in conjunctival secretions, and though the risk is relatively low, the eye may act as source of transmission. Extra caution should be taken by healthcare workers, and use of proper precautions like face shields and goggles should be encouraged. |
format | Online Article Text |
id | pubmed-8837307 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-88373072022-03-07 Detection of SARS-CoV-2 RNA in a conjunctival swab sample in real-time-polymerase chain reaction positive COVID-19 patients and its association with comorbidity and severity at a designated COVID-19 hospital in Central India Chawhan, Anagha Athale, Ashish Khan, Khalid Agarwal, Saurabh Paul, Rajdeep Iyer, Karthik Khadia, Anjali Som, Vivek Indian J Ophthalmol Expedited Publications, Original Article PURPOSE: To evaluate the presence of SARS-CoV-2 RNA in the conjunctival swab sample of positive confirmed COVID-19 patients and to find out its association with comorbidity and severity of COVID-19 disease. METHODS: We conducted an observational cross-sectional study at a dedicated tertiary COVID-19 hospital in central India for a period of 8 weeks from February 2021to March 2021. We included patients who tested positive for SARS-CoV-2 RNA through nasopharyngeal swab and were above 18 years of age. Swab samples have been collected within 48 h of admission. Conjunctival swab was taken from the lower fornix of both eyes and sent to microbiology laboratory for real-time- polymerase chain reaction (RT-PCR). RESULTS: Out of 150 patients, conjunctival swab RT-PCR was positive in five patients (3.33%). Two patients had conjunctival manifestations in the form of conjunctivitis but conjunctival swab RT-PCR was negative in those patients. Among the RT-PCR positive patients, two (40%) were from mild, one (20%) was from moderate, and two (40%) were from severe category. No association could be established between conjunctival swab RT-PCR positivity and severity of the disease or associated comorbidity. CONCLUSION: Our study provides evidence that SARS-CoV-2 RNA could be detected in conjunctival secretions, and though the risk is relatively low, the eye may act as source of transmission. Extra caution should be taken by healthcare workers, and use of proper precautions like face shields and goggles should be encouraged. Wolters Kluwer - Medknow 2021-12 2021-11-26 /pmc/articles/PMC8837307/ /pubmed/34827010 http://dx.doi.org/10.4103/ijo.IJO_1604_21 Text en Copyright: © 2021 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 4.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Expedited Publications, Original Article Chawhan, Anagha Athale, Ashish Khan, Khalid Agarwal, Saurabh Paul, Rajdeep Iyer, Karthik Khadia, Anjali Som, Vivek Detection of SARS-CoV-2 RNA in a conjunctival swab sample in real-time-polymerase chain reaction positive COVID-19 patients and its association with comorbidity and severity at a designated COVID-19 hospital in Central India |
title | Detection of SARS-CoV-2 RNA in a conjunctival swab sample in real-time-polymerase chain reaction positive COVID-19 patients and its association with comorbidity and severity at a designated COVID-19 hospital in Central India |
title_full | Detection of SARS-CoV-2 RNA in a conjunctival swab sample in real-time-polymerase chain reaction positive COVID-19 patients and its association with comorbidity and severity at a designated COVID-19 hospital in Central India |
title_fullStr | Detection of SARS-CoV-2 RNA in a conjunctival swab sample in real-time-polymerase chain reaction positive COVID-19 patients and its association with comorbidity and severity at a designated COVID-19 hospital in Central India |
title_full_unstemmed | Detection of SARS-CoV-2 RNA in a conjunctival swab sample in real-time-polymerase chain reaction positive COVID-19 patients and its association with comorbidity and severity at a designated COVID-19 hospital in Central India |
title_short | Detection of SARS-CoV-2 RNA in a conjunctival swab sample in real-time-polymerase chain reaction positive COVID-19 patients and its association with comorbidity and severity at a designated COVID-19 hospital in Central India |
title_sort | detection of sars-cov-2 rna in a conjunctival swab sample in real-time-polymerase chain reaction positive covid-19 patients and its association with comorbidity and severity at a designated covid-19 hospital in central india |
topic | Expedited Publications, Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8837307/ https://www.ncbi.nlm.nih.gov/pubmed/34827010 http://dx.doi.org/10.4103/ijo.IJO_1604_21 |
work_keys_str_mv | AT chawhananagha detectionofsarscov2rnainaconjunctivalswabsampleinrealtimepolymerasechainreactionpositivecovid19patientsanditsassociationwithcomorbidityandseverityatadesignatedcovid19hospitalincentralindia AT athaleashish detectionofsarscov2rnainaconjunctivalswabsampleinrealtimepolymerasechainreactionpositivecovid19patientsanditsassociationwithcomorbidityandseverityatadesignatedcovid19hospitalincentralindia AT khankhalid detectionofsarscov2rnainaconjunctivalswabsampleinrealtimepolymerasechainreactionpositivecovid19patientsanditsassociationwithcomorbidityandseverityatadesignatedcovid19hospitalincentralindia AT agarwalsaurabh detectionofsarscov2rnainaconjunctivalswabsampleinrealtimepolymerasechainreactionpositivecovid19patientsanditsassociationwithcomorbidityandseverityatadesignatedcovid19hospitalincentralindia AT paulrajdeep detectionofsarscov2rnainaconjunctivalswabsampleinrealtimepolymerasechainreactionpositivecovid19patientsanditsassociationwithcomorbidityandseverityatadesignatedcovid19hospitalincentralindia AT iyerkarthik detectionofsarscov2rnainaconjunctivalswabsampleinrealtimepolymerasechainreactionpositivecovid19patientsanditsassociationwithcomorbidityandseverityatadesignatedcovid19hospitalincentralindia AT khadiaanjali detectionofsarscov2rnainaconjunctivalswabsampleinrealtimepolymerasechainreactionpositivecovid19patientsanditsassociationwithcomorbidityandseverityatadesignatedcovid19hospitalincentralindia AT somvivek detectionofsarscov2rnainaconjunctivalswabsampleinrealtimepolymerasechainreactionpositivecovid19patientsanditsassociationwithcomorbidityandseverityatadesignatedcovid19hospitalincentralindia |