Cargando…

Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?

The major challenge these days in pediatric cataract surgery is not the technique of surgery or intraocular lens (IOL) used but the postoperative refractive error. Amblyopia occurring due to postoperative refractive error which the child has; destroys the benefit obtained by a near-perfect and timel...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaur, Savleen, Sukhija, Jaspreet, Ram, Jagat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8837349/
https://www.ncbi.nlm.nih.gov/pubmed/34826971
http://dx.doi.org/10.4103/ijo.IJO_371_21
_version_ 1784649889302446080
author Kaur, Savleen
Sukhija, Jaspreet
Ram, Jagat
author_facet Kaur, Savleen
Sukhija, Jaspreet
Ram, Jagat
author_sort Kaur, Savleen
collection PubMed
description The major challenge these days in pediatric cataract surgery is not the technique of surgery or intraocular lens (IOL) used but the postoperative refractive error. Amblyopia occurring due to postoperative refractive error which the child has; destroys the benefit obtained by a near-perfect and timely surgery. Even if we settle the debate as to what should be the ideal postoperative target refraction, there is a postoperative surprise that is not explained by our conventional insights of an accurate power calculation in children. The role of IOL power calculation formulae in affecting the postoperative refractive error should not be underestimated. Therefore, which age-appropriate formula is to be used for children is unclear. This review is an update on major IOL power calculation formulas used in pediatric eyes. We have tried to define why we should not be using these formulas made for adult eyes and review the literature in this regard.
format Online
Article
Text
id pubmed-8837349
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-88373492022-03-07 Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes? Kaur, Savleen Sukhija, Jaspreet Ram, Jagat Indian J Ophthalmol Review Article The major challenge these days in pediatric cataract surgery is not the technique of surgery or intraocular lens (IOL) used but the postoperative refractive error. Amblyopia occurring due to postoperative refractive error which the child has; destroys the benefit obtained by a near-perfect and timely surgery. Even if we settle the debate as to what should be the ideal postoperative target refraction, there is a postoperative surprise that is not explained by our conventional insights of an accurate power calculation in children. The role of IOL power calculation formulae in affecting the postoperative refractive error should not be underestimated. Therefore, which age-appropriate formula is to be used for children is unclear. This review is an update on major IOL power calculation formulas used in pediatric eyes. We have tried to define why we should not be using these formulas made for adult eyes and review the literature in this regard. Wolters Kluwer - Medknow 2021-12 2021-11-26 /pmc/articles/PMC8837349/ /pubmed/34826971 http://dx.doi.org/10.4103/ijo.IJO_371_21 Text en Copyright: © 2021 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 4.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Kaur, Savleen
Sukhija, Jaspreet
Ram, Jagat
Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?
title Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?
title_full Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?
title_fullStr Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?
title_full_unstemmed Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?
title_short Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?
title_sort intraocular lens power calculation formula in congenital cataracts: are we using the correct formula for pediatric eyes?
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8837349/
https://www.ncbi.nlm.nih.gov/pubmed/34826971
http://dx.doi.org/10.4103/ijo.IJO_371_21
work_keys_str_mv AT kaursavleen intraocularlenspowercalculationformulaincongenitalcataractsareweusingthecorrectformulaforpediatriceyes
AT sukhijajaspreet intraocularlenspowercalculationformulaincongenitalcataractsareweusingthecorrectformulaforpediatriceyes
AT ramjagat intraocularlenspowercalculationformulaincongenitalcataractsareweusingthecorrectformulaforpediatriceyes