Cargando…

Mechanical Properties, Cytotoxicity, and Fluoride Ion Release Capacity of Bioactive Glass-Modified Methacrylate Resin Used in Three-Dimensional Printing Technology

Background: Clinically, three-dimensional (3D) printing technology is becoming a popular and efficient dental processing technology. Recently, there has been an increasing demand for dental materials that exhibit bioactive properties. The present study aimed to evaluate the mechanical properties, cy...

Descripción completa

Detalles Bibliográficos
Autores principales: Raszewski, Zbigniew, Kulbacka, Julita, Nowakowska-Toporowska, Agnieszka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838011/
https://www.ncbi.nlm.nih.gov/pubmed/35161076
http://dx.doi.org/10.3390/ma15031133
_version_ 1784650020391223296
author Raszewski, Zbigniew
Kulbacka, Julita
Nowakowska-Toporowska, Agnieszka
author_facet Raszewski, Zbigniew
Kulbacka, Julita
Nowakowska-Toporowska, Agnieszka
author_sort Raszewski, Zbigniew
collection PubMed
description Background: Clinically, three-dimensional (3D) printing technology is becoming a popular and efficient dental processing technology. Recently, there has been an increasing demand for dental materials that exhibit bioactive properties. The present study aimed to evaluate the mechanical properties, cytotoxicity, and fluoride ion release capacity of 3D-printed dental resins modified with bioactive glass. Materials and methods: The resin FotoDent splint used in the production of removable orthodontic splints, was modified by the addition of two types of bioactive glasses that are capable of releasing fluoride ions. The novel materials used for the production of dental splints were examined for their mechanical, physical, and biological properties (fracture resistance, sorption, solubility, elution of nonpolymeric substances, and release of fluoride ions over time) and cytotoxic effects on cell cultures. Results: Initially, the fracture toughness of the 3D-printed resin was found to be 55 MPa, but after modification with glass, the resistance was reduced to about 50 MPa. Sorption and solubility values of the materials (19.01 ÷ 21.23 µg/mm(3) and 0.42 ÷ 1.12 µg/mm(3), respectively) complied with the safety limits imposed by ISO standard. Modified resins were capable of releasing fluoride ions, and the maximum releasing effect was observed after 14 days of incubation. Both the modified resins, after four days of contact with human gingival fibroblasts, exhibited moderate cytotoxic properties. Conclusions: The experimental results showed that modification of methacrylate resin, used in 3D printing technology, with bioactive glasses produces novel dental materials that possess desirable bioactive properties. The findings of this study indicate the potential ability of modified polymethacrylate resins to release fluoride ions in the oral cavity environment. The modified materials are characterized with a moderate decrease in physical properties and mild cytotoxicity on direct contact with human fibroblasts.
format Online
Article
Text
id pubmed-8838011
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88380112022-02-13 Mechanical Properties, Cytotoxicity, and Fluoride Ion Release Capacity of Bioactive Glass-Modified Methacrylate Resin Used in Three-Dimensional Printing Technology Raszewski, Zbigniew Kulbacka, Julita Nowakowska-Toporowska, Agnieszka Materials (Basel) Article Background: Clinically, three-dimensional (3D) printing technology is becoming a popular and efficient dental processing technology. Recently, there has been an increasing demand for dental materials that exhibit bioactive properties. The present study aimed to evaluate the mechanical properties, cytotoxicity, and fluoride ion release capacity of 3D-printed dental resins modified with bioactive glass. Materials and methods: The resin FotoDent splint used in the production of removable orthodontic splints, was modified by the addition of two types of bioactive glasses that are capable of releasing fluoride ions. The novel materials used for the production of dental splints were examined for their mechanical, physical, and biological properties (fracture resistance, sorption, solubility, elution of nonpolymeric substances, and release of fluoride ions over time) and cytotoxic effects on cell cultures. Results: Initially, the fracture toughness of the 3D-printed resin was found to be 55 MPa, but after modification with glass, the resistance was reduced to about 50 MPa. Sorption and solubility values of the materials (19.01 ÷ 21.23 µg/mm(3) and 0.42 ÷ 1.12 µg/mm(3), respectively) complied with the safety limits imposed by ISO standard. Modified resins were capable of releasing fluoride ions, and the maximum releasing effect was observed after 14 days of incubation. Both the modified resins, after four days of contact with human gingival fibroblasts, exhibited moderate cytotoxic properties. Conclusions: The experimental results showed that modification of methacrylate resin, used in 3D printing technology, with bioactive glasses produces novel dental materials that possess desirable bioactive properties. The findings of this study indicate the potential ability of modified polymethacrylate resins to release fluoride ions in the oral cavity environment. The modified materials are characterized with a moderate decrease in physical properties and mild cytotoxicity on direct contact with human fibroblasts. MDPI 2022-02-01 /pmc/articles/PMC8838011/ /pubmed/35161076 http://dx.doi.org/10.3390/ma15031133 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Raszewski, Zbigniew
Kulbacka, Julita
Nowakowska-Toporowska, Agnieszka
Mechanical Properties, Cytotoxicity, and Fluoride Ion Release Capacity of Bioactive Glass-Modified Methacrylate Resin Used in Three-Dimensional Printing Technology
title Mechanical Properties, Cytotoxicity, and Fluoride Ion Release Capacity of Bioactive Glass-Modified Methacrylate Resin Used in Three-Dimensional Printing Technology
title_full Mechanical Properties, Cytotoxicity, and Fluoride Ion Release Capacity of Bioactive Glass-Modified Methacrylate Resin Used in Three-Dimensional Printing Technology
title_fullStr Mechanical Properties, Cytotoxicity, and Fluoride Ion Release Capacity of Bioactive Glass-Modified Methacrylate Resin Used in Three-Dimensional Printing Technology
title_full_unstemmed Mechanical Properties, Cytotoxicity, and Fluoride Ion Release Capacity of Bioactive Glass-Modified Methacrylate Resin Used in Three-Dimensional Printing Technology
title_short Mechanical Properties, Cytotoxicity, and Fluoride Ion Release Capacity of Bioactive Glass-Modified Methacrylate Resin Used in Three-Dimensional Printing Technology
title_sort mechanical properties, cytotoxicity, and fluoride ion release capacity of bioactive glass-modified methacrylate resin used in three-dimensional printing technology
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838011/
https://www.ncbi.nlm.nih.gov/pubmed/35161076
http://dx.doi.org/10.3390/ma15031133
work_keys_str_mv AT raszewskizbigniew mechanicalpropertiescytotoxicityandfluorideionreleasecapacityofbioactiveglassmodifiedmethacrylateresinusedinthreedimensionalprintingtechnology
AT kulbackajulita mechanicalpropertiescytotoxicityandfluorideionreleasecapacityofbioactiveglassmodifiedmethacrylateresinusedinthreedimensionalprintingtechnology
AT nowakowskatoporowskaagnieszka mechanicalpropertiescytotoxicityandfluorideionreleasecapacityofbioactiveglassmodifiedmethacrylateresinusedinthreedimensionalprintingtechnology