Cargando…

Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples

A very simple, as well as sensitive and selective, sensing protocol was developed on a pre-anodized graphite pencil electrode surface coated using poly(thionine) (APGE/PTH). The poly(thionine) coated graphite pencil was then used for simultaneous sensing of 3-nitrophenol (3-NP) and 4-nitrophenol (4-...

Descripción completa

Detalles Bibliográficos
Autores principales: Sree, Vijaya Gopalan, Sohn, Jung Inn, Im, Hyunsik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838205/
https://www.ncbi.nlm.nih.gov/pubmed/35161895
http://dx.doi.org/10.3390/s22031151
_version_ 1784650068733722624
author Sree, Vijaya Gopalan
Sohn, Jung Inn
Im, Hyunsik
author_facet Sree, Vijaya Gopalan
Sohn, Jung Inn
Im, Hyunsik
author_sort Sree, Vijaya Gopalan
collection PubMed
description A very simple, as well as sensitive and selective, sensing protocol was developed on a pre-anodized graphite pencil electrode surface coated using poly(thionine) (APGE/PTH). The poly(thionine) coated graphite pencil was then used for simultaneous sensing of 3-nitrophenol (3-NP) and 4-nitrophenol (4-NP). The poly(thionine) coated electrode exhibited an enhanced electrocatalytic property towards nitrophenol (3-NP and 4-NP) reduction. Redox peak potential and current of both nitrophenols were found well resolved and their simultaneous analysis was studied. Under optimized experimental conditions, APGE/PTH showed a long linear concentration range from 20 to 230 nM and 15 nM to 280 nM with a calculated limit of detection (LOD) of 4.5 and 4 nM and a sensitivity of 22.45 µA/nM and 27.12 µA/nM for 3-NP and 4-NP, respectively. Real sample analysis using the prepared sensor was tested with different environmental water samples and the sensors exhibited excellent recovery results in the range from 98.16 to 103.43%. Finally, the sensor exposed an promising selectivity, stability, and reproducibility towards sensing of 3-NP and 4-NP.
format Online
Article
Text
id pubmed-8838205
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88382052022-02-13 Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples Sree, Vijaya Gopalan Sohn, Jung Inn Im, Hyunsik Sensors (Basel) Article A very simple, as well as sensitive and selective, sensing protocol was developed on a pre-anodized graphite pencil electrode surface coated using poly(thionine) (APGE/PTH). The poly(thionine) coated graphite pencil was then used for simultaneous sensing of 3-nitrophenol (3-NP) and 4-nitrophenol (4-NP). The poly(thionine) coated electrode exhibited an enhanced electrocatalytic property towards nitrophenol (3-NP and 4-NP) reduction. Redox peak potential and current of both nitrophenols were found well resolved and their simultaneous analysis was studied. Under optimized experimental conditions, APGE/PTH showed a long linear concentration range from 20 to 230 nM and 15 nM to 280 nM with a calculated limit of detection (LOD) of 4.5 and 4 nM and a sensitivity of 22.45 µA/nM and 27.12 µA/nM for 3-NP and 4-NP, respectively. Real sample analysis using the prepared sensor was tested with different environmental water samples and the sensors exhibited excellent recovery results in the range from 98.16 to 103.43%. Finally, the sensor exposed an promising selectivity, stability, and reproducibility towards sensing of 3-NP and 4-NP. MDPI 2022-02-02 /pmc/articles/PMC8838205/ /pubmed/35161895 http://dx.doi.org/10.3390/s22031151 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sree, Vijaya Gopalan
Sohn, Jung Inn
Im, Hyunsik
Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples
title Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples
title_full Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples
title_fullStr Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples
title_full_unstemmed Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples
title_short Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples
title_sort pre-anodized graphite pencil electrode coated with a poly(thionine) film for simultaneous sensing of 3-nitrophenol and 4-nitrophenol in environmental water samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838205/
https://www.ncbi.nlm.nih.gov/pubmed/35161895
http://dx.doi.org/10.3390/s22031151
work_keys_str_mv AT sreevijayagopalan preanodizedgraphitepencilelectrodecoatedwithapolythioninefilmforsimultaneoussensingof3nitrophenoland4nitrophenolinenvironmentalwatersamples
AT sohnjunginn preanodizedgraphitepencilelectrodecoatedwithapolythioninefilmforsimultaneoussensingof3nitrophenoland4nitrophenolinenvironmentalwatersamples
AT imhyunsik preanodizedgraphitepencilelectrodecoatedwithapolythioninefilmforsimultaneoussensingof3nitrophenoland4nitrophenolinenvironmentalwatersamples