Cargando…

Determination of Time Domain Reflectometry Surface Sensors Sensitivity Depending on Geometry and Material Moisture

The article concerns the electric techniques of moisture detection that are based on the evaluation of the apparent permittivity of the tested medium. The main goal of the research was to evaluate the non-invasive Time Domain Reflectometry (TDR) sensors’ sensitivity by measuring the span of elements...

Descripción completa

Detalles Bibliográficos
Autores principales: Suchorab, Zbigniew, Malec, Agnieszka, Sobczuk, Henryk, Łagód, Grzegorz, Gorgol, Izolda, Łazuka, Ewa, Brzyski, Przemysław, Trník, Anton
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838417/
https://www.ncbi.nlm.nih.gov/pubmed/35161481
http://dx.doi.org/10.3390/s22030735
_version_ 1784650122292887552
author Suchorab, Zbigniew
Malec, Agnieszka
Sobczuk, Henryk
Łagód, Grzegorz
Gorgol, Izolda
Łazuka, Ewa
Brzyski, Przemysław
Trník, Anton
author_facet Suchorab, Zbigniew
Malec, Agnieszka
Sobczuk, Henryk
Łagód, Grzegorz
Gorgol, Izolda
Łazuka, Ewa
Brzyski, Przemysław
Trník, Anton
author_sort Suchorab, Zbigniew
collection PubMed
description The article concerns the electric techniques of moisture detection that are based on the evaluation of the apparent permittivity of the tested medium. The main goal of the research was to evaluate the non-invasive Time Domain Reflectometry (TDR) sensors’ sensitivity by measuring the span of elements and material moisture. To that aim, two non-invasive sensor designs were investigated for their sensitivity in the evaluation of the apparent permittivity value of aerated concrete. Sensors A and B were characterized by the spacing between the measuring elements equal to 30 mm and 70 mm, respectively. The tested samples differed in moisture, ranging between 0 and 0.3 cm(3)/cm(3) volumetric water content. Within the research, it was stated that in the case of the narrower sensor (A), the range of the sensor equals about 30 mm, and in the case of the wider design (B), it equals about 50 mm. Additionally, it was stated that material moisture influences the range of sensor influence. In the case of the dry and low-saturated material, it was not possible to evaluate the range of sensor sensitivity using the adopted method, whereas the range of sensor signal influence was visible for the moist material.
format Online
Article
Text
id pubmed-8838417
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88384172022-02-13 Determination of Time Domain Reflectometry Surface Sensors Sensitivity Depending on Geometry and Material Moisture Suchorab, Zbigniew Malec, Agnieszka Sobczuk, Henryk Łagód, Grzegorz Gorgol, Izolda Łazuka, Ewa Brzyski, Przemysław Trník, Anton Sensors (Basel) Article The article concerns the electric techniques of moisture detection that are based on the evaluation of the apparent permittivity of the tested medium. The main goal of the research was to evaluate the non-invasive Time Domain Reflectometry (TDR) sensors’ sensitivity by measuring the span of elements and material moisture. To that aim, two non-invasive sensor designs were investigated for their sensitivity in the evaluation of the apparent permittivity value of aerated concrete. Sensors A and B were characterized by the spacing between the measuring elements equal to 30 mm and 70 mm, respectively. The tested samples differed in moisture, ranging between 0 and 0.3 cm(3)/cm(3) volumetric water content. Within the research, it was stated that in the case of the narrower sensor (A), the range of the sensor equals about 30 mm, and in the case of the wider design (B), it equals about 50 mm. Additionally, it was stated that material moisture influences the range of sensor influence. In the case of the dry and low-saturated material, it was not possible to evaluate the range of sensor sensitivity using the adopted method, whereas the range of sensor signal influence was visible for the moist material. MDPI 2022-01-19 /pmc/articles/PMC8838417/ /pubmed/35161481 http://dx.doi.org/10.3390/s22030735 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Suchorab, Zbigniew
Malec, Agnieszka
Sobczuk, Henryk
Łagód, Grzegorz
Gorgol, Izolda
Łazuka, Ewa
Brzyski, Przemysław
Trník, Anton
Determination of Time Domain Reflectometry Surface Sensors Sensitivity Depending on Geometry and Material Moisture
title Determination of Time Domain Reflectometry Surface Sensors Sensitivity Depending on Geometry and Material Moisture
title_full Determination of Time Domain Reflectometry Surface Sensors Sensitivity Depending on Geometry and Material Moisture
title_fullStr Determination of Time Domain Reflectometry Surface Sensors Sensitivity Depending on Geometry and Material Moisture
title_full_unstemmed Determination of Time Domain Reflectometry Surface Sensors Sensitivity Depending on Geometry and Material Moisture
title_short Determination of Time Domain Reflectometry Surface Sensors Sensitivity Depending on Geometry and Material Moisture
title_sort determination of time domain reflectometry surface sensors sensitivity depending on geometry and material moisture
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838417/
https://www.ncbi.nlm.nih.gov/pubmed/35161481
http://dx.doi.org/10.3390/s22030735
work_keys_str_mv AT suchorabzbigniew determinationoftimedomainreflectometrysurfacesensorssensitivitydependingongeometryandmaterialmoisture
AT malecagnieszka determinationoftimedomainreflectometrysurfacesensorssensitivitydependingongeometryandmaterialmoisture
AT sobczukhenryk determinationoftimedomainreflectometrysurfacesensorssensitivitydependingongeometryandmaterialmoisture
AT łagodgrzegorz determinationoftimedomainreflectometrysurfacesensorssensitivitydependingongeometryandmaterialmoisture
AT gorgolizolda determinationoftimedomainreflectometrysurfacesensorssensitivitydependingongeometryandmaterialmoisture
AT łazukaewa determinationoftimedomainreflectometrysurfacesensorssensitivitydependingongeometryandmaterialmoisture
AT brzyskiprzemysław determinationoftimedomainreflectometrysurfacesensorssensitivitydependingongeometryandmaterialmoisture
AT trnikanton determinationoftimedomainreflectometrysurfacesensorssensitivitydependingongeometryandmaterialmoisture