Cargando…
Development of a Low-Cost 6 DOF Brick Tracking System for Use in Advanced Gas-Cooled Reactor Model Tests
This paper presents the design of a low-cost, compact instrumentation system to enable six degree of freedom motion tracking of acetal bricks within an experimental model of a cracked Advanced Gas-Cooled Reactor (AGR) core. The system comprises optical and inertial sensors and capitalises on the adv...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838487/ https://www.ncbi.nlm.nih.gov/pubmed/35161855 http://dx.doi.org/10.3390/s22031110 |
_version_ | 1784650139711832064 |
---|---|
author | Olson, Paolo Crewe, Adam J. Gokce, Tansu Horseman, Tony White, Rory E. |
author_facet | Olson, Paolo Crewe, Adam J. Gokce, Tansu Horseman, Tony White, Rory E. |
author_sort | Olson, Paolo |
collection | PubMed |
description | This paper presents the design of a low-cost, compact instrumentation system to enable six degree of freedom motion tracking of acetal bricks within an experimental model of a cracked Advanced Gas-Cooled Reactor (AGR) core. The system comprises optical and inertial sensors and capitalises on the advantages offered by data fusion techniques. The optical system tracks LED indicators, allowing a brick to be accurately located even in cluttered images. The LED positions are identified using a geometrical correspondence algorithm, which was optimised to be computationally efficient for shallow movements, and complex camera distortions are corrected using a versatile Incident Ray-Tracking calibration. Then, a Perspective-Ray-based Scaled Orthographic projection with Iteration (PRSOI) algorithm is applied to each LED position to determine the six degree of freedom pose. Results from experiments show that the system achieves a low Root Mean Squared (RMS) error of 0.2296 mm in x, 0.3943 mm in y, and 0.0703 mm in z. Although providing an accurate measurement solution, the optical tracking system has a low sample rate and requires the line of sight to be maintained throughout each test. To increase the robustness, accuracy, and sampling frequency of the system, the optical system can be augmented with an Inertial Measurement Unit (IMU). This paper presents a method to integrate the optical system and IMU data by accurately timestamping data from each set of sensors and aligning the two coordinate axes. Once miniaturised, the developed system will be used to track smaller components within the AGR models that cannot be tracked with current instrumentation, expanding reactor core modelling capabilities. |
format | Online Article Text |
id | pubmed-8838487 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-88384872022-02-13 Development of a Low-Cost 6 DOF Brick Tracking System for Use in Advanced Gas-Cooled Reactor Model Tests Olson, Paolo Crewe, Adam J. Gokce, Tansu Horseman, Tony White, Rory E. Sensors (Basel) Article This paper presents the design of a low-cost, compact instrumentation system to enable six degree of freedom motion tracking of acetal bricks within an experimental model of a cracked Advanced Gas-Cooled Reactor (AGR) core. The system comprises optical and inertial sensors and capitalises on the advantages offered by data fusion techniques. The optical system tracks LED indicators, allowing a brick to be accurately located even in cluttered images. The LED positions are identified using a geometrical correspondence algorithm, which was optimised to be computationally efficient for shallow movements, and complex camera distortions are corrected using a versatile Incident Ray-Tracking calibration. Then, a Perspective-Ray-based Scaled Orthographic projection with Iteration (PRSOI) algorithm is applied to each LED position to determine the six degree of freedom pose. Results from experiments show that the system achieves a low Root Mean Squared (RMS) error of 0.2296 mm in x, 0.3943 mm in y, and 0.0703 mm in z. Although providing an accurate measurement solution, the optical tracking system has a low sample rate and requires the line of sight to be maintained throughout each test. To increase the robustness, accuracy, and sampling frequency of the system, the optical system can be augmented with an Inertial Measurement Unit (IMU). This paper presents a method to integrate the optical system and IMU data by accurately timestamping data from each set of sensors and aligning the two coordinate axes. Once miniaturised, the developed system will be used to track smaller components within the AGR models that cannot be tracked with current instrumentation, expanding reactor core modelling capabilities. MDPI 2022-02-01 /pmc/articles/PMC8838487/ /pubmed/35161855 http://dx.doi.org/10.3390/s22031110 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Olson, Paolo Crewe, Adam J. Gokce, Tansu Horseman, Tony White, Rory E. Development of a Low-Cost 6 DOF Brick Tracking System for Use in Advanced Gas-Cooled Reactor Model Tests |
title | Development of a Low-Cost 6 DOF Brick Tracking System for Use in Advanced Gas-Cooled Reactor Model Tests |
title_full | Development of a Low-Cost 6 DOF Brick Tracking System for Use in Advanced Gas-Cooled Reactor Model Tests |
title_fullStr | Development of a Low-Cost 6 DOF Brick Tracking System for Use in Advanced Gas-Cooled Reactor Model Tests |
title_full_unstemmed | Development of a Low-Cost 6 DOF Brick Tracking System for Use in Advanced Gas-Cooled Reactor Model Tests |
title_short | Development of a Low-Cost 6 DOF Brick Tracking System for Use in Advanced Gas-Cooled Reactor Model Tests |
title_sort | development of a low-cost 6 dof brick tracking system for use in advanced gas-cooled reactor model tests |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838487/ https://www.ncbi.nlm.nih.gov/pubmed/35161855 http://dx.doi.org/10.3390/s22031110 |
work_keys_str_mv | AT olsonpaolo developmentofalowcost6dofbricktrackingsystemforuseinadvancedgascooledreactormodeltests AT creweadamj developmentofalowcost6dofbricktrackingsystemforuseinadvancedgascooledreactormodeltests AT gokcetansu developmentofalowcost6dofbricktrackingsystemforuseinadvancedgascooledreactormodeltests AT horsemantony developmentofalowcost6dofbricktrackingsystemforuseinadvancedgascooledreactormodeltests AT whiterorye developmentofalowcost6dofbricktrackingsystemforuseinadvancedgascooledreactormodeltests |