Cargando…

Study of the Optimal Composition and Storage Conditions of the Fricke–XO–Pluronic F–127 Radiochromic Dosimeter

This paper presents the results of research on the Fricke–XO–Pluronic F–127 dosimeter. It consists of a Fricke dosimetric solution and xylenol orange (XO), which are embedded in a matrix of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F–127). Upon irradiation...

Descripción completa

Detalles Bibliográficos
Autores principales: Piotrowski, Michał, Maras, Piotr, Kadłubowski, Sławomir, Kozicki, Marek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838533/
https://www.ncbi.nlm.nih.gov/pubmed/35160929
http://dx.doi.org/10.3390/ma15030984
_version_ 1784650150921109504
author Piotrowski, Michał
Maras, Piotr
Kadłubowski, Sławomir
Kozicki, Marek
author_facet Piotrowski, Michał
Maras, Piotr
Kadłubowski, Sławomir
Kozicki, Marek
author_sort Piotrowski, Michał
collection PubMed
description This paper presents the results of research on the Fricke–XO–Pluronic F–127 dosimeter. It consists of a Fricke dosimetric solution and xylenol orange (XO), which are embedded in a matrix of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F–127). Upon irradiation, Fe(+2) ions transform into Fe(+3), forming a colored complex with XO ([XO-Fe](+3)). The color intensity is related to the dose absorbed. The optimal composition, storage conditions, and radiation-induced performance of the Fricke–XO–Pluronic F–127 dosimeter were investigated. The optimal composition was found to be 1 mM FAS, 50 mM sulfuric acid (H(2)SO(4)), 0.165 mM XO in 25% Pluronic F–127. The basic features of this dosimeter are discussed, such as dose sensitivity, linear and dynamic dose range, stability before and after irradiation, storage conditions, dose response for irradiation with 6 and 15 MV photons, and batch-to-batch reproducibility. The obtained results showed a certain potential of the Fricke–XO–Pluronic F–127 for radiotherapy dosimetry.
format Online
Article
Text
id pubmed-8838533
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88385332022-02-13 Study of the Optimal Composition and Storage Conditions of the Fricke–XO–Pluronic F–127 Radiochromic Dosimeter Piotrowski, Michał Maras, Piotr Kadłubowski, Sławomir Kozicki, Marek Materials (Basel) Article This paper presents the results of research on the Fricke–XO–Pluronic F–127 dosimeter. It consists of a Fricke dosimetric solution and xylenol orange (XO), which are embedded in a matrix of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F–127). Upon irradiation, Fe(+2) ions transform into Fe(+3), forming a colored complex with XO ([XO-Fe](+3)). The color intensity is related to the dose absorbed. The optimal composition, storage conditions, and radiation-induced performance of the Fricke–XO–Pluronic F–127 dosimeter were investigated. The optimal composition was found to be 1 mM FAS, 50 mM sulfuric acid (H(2)SO(4)), 0.165 mM XO in 25% Pluronic F–127. The basic features of this dosimeter are discussed, such as dose sensitivity, linear and dynamic dose range, stability before and after irradiation, storage conditions, dose response for irradiation with 6 and 15 MV photons, and batch-to-batch reproducibility. The obtained results showed a certain potential of the Fricke–XO–Pluronic F–127 for radiotherapy dosimetry. MDPI 2022-01-27 /pmc/articles/PMC8838533/ /pubmed/35160929 http://dx.doi.org/10.3390/ma15030984 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Piotrowski, Michał
Maras, Piotr
Kadłubowski, Sławomir
Kozicki, Marek
Study of the Optimal Composition and Storage Conditions of the Fricke–XO–Pluronic F–127 Radiochromic Dosimeter
title Study of the Optimal Composition and Storage Conditions of the Fricke–XO–Pluronic F–127 Radiochromic Dosimeter
title_full Study of the Optimal Composition and Storage Conditions of the Fricke–XO–Pluronic F–127 Radiochromic Dosimeter
title_fullStr Study of the Optimal Composition and Storage Conditions of the Fricke–XO–Pluronic F–127 Radiochromic Dosimeter
title_full_unstemmed Study of the Optimal Composition and Storage Conditions of the Fricke–XO–Pluronic F–127 Radiochromic Dosimeter
title_short Study of the Optimal Composition and Storage Conditions of the Fricke–XO–Pluronic F–127 Radiochromic Dosimeter
title_sort study of the optimal composition and storage conditions of the fricke–xo–pluronic f–127 radiochromic dosimeter
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838533/
https://www.ncbi.nlm.nih.gov/pubmed/35160929
http://dx.doi.org/10.3390/ma15030984
work_keys_str_mv AT piotrowskimichał studyoftheoptimalcompositionandstorageconditionsofthefrickexopluronicf127radiochromicdosimeter
AT maraspiotr studyoftheoptimalcompositionandstorageconditionsofthefrickexopluronicf127radiochromicdosimeter
AT kadłubowskisławomir studyoftheoptimalcompositionandstorageconditionsofthefrickexopluronicf127radiochromicdosimeter
AT kozickimarek studyoftheoptimalcompositionandstorageconditionsofthefrickexopluronicf127radiochromicdosimeter