Cargando…
Feasibility Study of Glucose Concentration Measurement of Aqueous Solution Using Time Domain Reflected Signals
Recently, wideband microwave spectroscopy (WBMS) has been applied for material characterization. Blood glucose sensing through microwave spectroscopy is usually done with resonant frequency-domain methods. Time-domain (TD) WBMS is a low-cost and convenient technique that can be used for glucose sens...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838697/ https://www.ncbi.nlm.nih.gov/pubmed/35161919 http://dx.doi.org/10.3390/s22031174 |
_version_ | 1784650189866270720 |
---|---|
author | Saeedi, Samira Chammani, Somayyeh Fischer, Georg |
author_facet | Saeedi, Samira Chammani, Somayyeh Fischer, Georg |
author_sort | Saeedi, Samira |
collection | PubMed |
description | Recently, wideband microwave spectroscopy (WBMS) has been applied for material characterization. Blood glucose sensing through microwave spectroscopy is usually done with resonant frequency-domain methods. Time-domain (TD) WBMS is a low-cost and convenient technique that can be used for glucose sensing of the aqueous solution. In this paper, early research for the implementation of a TD dielectric spectroscopy setup for glucose concentration measurement is presented. TD reflected signals from water with different glucose content are calculated using inverse Laplace transform. The proposed setup is a quasi-monostatic setup in which measurements are done with two different devices in the frequency range of 0.1 to 6 GHz to make a comparison between frequency domain (FD) and TD methods. Frequency domain (FD) measurement is performed with VNA and two Vivaldi antennas. Then, TD data is obtained using the transforming option of VNA. Direct TD measurement is operated with a maximum length sequence (m-sequence) transceiver. Measurement and numerical results follow the same trend and show good agreement with each other. A monotonic relation between peaks of TD signals and the corresponding glucose concentration is achieved. The variation of the height of the reflected signal’s peak is 0.00002 and 0.0005 for each 50 mg/dL glucose concentration with FD measurements and direct TD measurements, respectively. The glucose concentration range of 25 mg/dL to 400 mg/dL is investigated, and the worst repeatability of this method is 3.65% for 300 mg/dL. |
format | Online Article Text |
id | pubmed-8838697 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-88386972022-02-13 Feasibility Study of Glucose Concentration Measurement of Aqueous Solution Using Time Domain Reflected Signals Saeedi, Samira Chammani, Somayyeh Fischer, Georg Sensors (Basel) Article Recently, wideband microwave spectroscopy (WBMS) has been applied for material characterization. Blood glucose sensing through microwave spectroscopy is usually done with resonant frequency-domain methods. Time-domain (TD) WBMS is a low-cost and convenient technique that can be used for glucose sensing of the aqueous solution. In this paper, early research for the implementation of a TD dielectric spectroscopy setup for glucose concentration measurement is presented. TD reflected signals from water with different glucose content are calculated using inverse Laplace transform. The proposed setup is a quasi-monostatic setup in which measurements are done with two different devices in the frequency range of 0.1 to 6 GHz to make a comparison between frequency domain (FD) and TD methods. Frequency domain (FD) measurement is performed with VNA and two Vivaldi antennas. Then, TD data is obtained using the transforming option of VNA. Direct TD measurement is operated with a maximum length sequence (m-sequence) transceiver. Measurement and numerical results follow the same trend and show good agreement with each other. A monotonic relation between peaks of TD signals and the corresponding glucose concentration is achieved. The variation of the height of the reflected signal’s peak is 0.00002 and 0.0005 for each 50 mg/dL glucose concentration with FD measurements and direct TD measurements, respectively. The glucose concentration range of 25 mg/dL to 400 mg/dL is investigated, and the worst repeatability of this method is 3.65% for 300 mg/dL. MDPI 2022-02-03 /pmc/articles/PMC8838697/ /pubmed/35161919 http://dx.doi.org/10.3390/s22031174 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Saeedi, Samira Chammani, Somayyeh Fischer, Georg Feasibility Study of Glucose Concentration Measurement of Aqueous Solution Using Time Domain Reflected Signals |
title | Feasibility Study of Glucose Concentration Measurement of Aqueous Solution Using Time Domain Reflected Signals |
title_full | Feasibility Study of Glucose Concentration Measurement of Aqueous Solution Using Time Domain Reflected Signals |
title_fullStr | Feasibility Study of Glucose Concentration Measurement of Aqueous Solution Using Time Domain Reflected Signals |
title_full_unstemmed | Feasibility Study of Glucose Concentration Measurement of Aqueous Solution Using Time Domain Reflected Signals |
title_short | Feasibility Study of Glucose Concentration Measurement of Aqueous Solution Using Time Domain Reflected Signals |
title_sort | feasibility study of glucose concentration measurement of aqueous solution using time domain reflected signals |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8838697/ https://www.ncbi.nlm.nih.gov/pubmed/35161919 http://dx.doi.org/10.3390/s22031174 |
work_keys_str_mv | AT saeedisamira feasibilitystudyofglucoseconcentrationmeasurementofaqueoussolutionusingtimedomainreflectedsignals AT chammanisomayyeh feasibilitystudyofglucoseconcentrationmeasurementofaqueoussolutionusingtimedomainreflectedsignals AT fischergeorg feasibilitystudyofglucoseconcentrationmeasurementofaqueoussolutionusingtimedomainreflectedsignals |