Cargando…
Mixed Fault Classification of Sensorless PMSM Drive in Dynamic Operations Based on External Stray Flux Sensors
This paper aims to classify local demagnetisation and inter-turn short-circuit (ITSC) on position sensorless permanent magnet synchronous motors (PMSM) in transient states based on external stray flux and learning classifier. Within the framework, four supervised machine learning tools were tested:...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8839937/ https://www.ncbi.nlm.nih.gov/pubmed/35161959 http://dx.doi.org/10.3390/s22031216 |
_version_ | 1784650494183997440 |
---|---|
author | Attestog, Sveinung Senanayaka, Jagath Sri Lal Van Khang, Huynh Robbersmyr, Kjell G. |
author_facet | Attestog, Sveinung Senanayaka, Jagath Sri Lal Van Khang, Huynh Robbersmyr, Kjell G. |
author_sort | Attestog, Sveinung |
collection | PubMed |
description | This paper aims to classify local demagnetisation and inter-turn short-circuit (ITSC) on position sensorless permanent magnet synchronous motors (PMSM) in transient states based on external stray flux and learning classifier. Within the framework, four supervised machine learning tools were tested: ensemble decision tree (EDT), k-nearest neighbours (KNN), support vector machine (SVM), and feedforward neural network (FNN). All algorithms are trained on datasets from one operational profile but tested on other different operation profiles. Their input features or spectrograms are computed from resampled time-series data based on the estimated position of the rotor from one stray flux sensor through an optimisation problem. This eliminates the need for the position sensors, allowing for the fault classification of sensorless PMSM drives using only two external stray flux sensors alone. Both SVM and FNN algorithms could identify a single fault of the magnet defect with an accuracy higher than 95% in transient states. For mixed faults, the FNN-based algorithm could identify ITSC in parallel-strands stator winding and local partial demagnetisation with an accuracy of 87.1%. |
format | Online Article Text |
id | pubmed-8839937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-88399372022-02-13 Mixed Fault Classification of Sensorless PMSM Drive in Dynamic Operations Based on External Stray Flux Sensors Attestog, Sveinung Senanayaka, Jagath Sri Lal Van Khang, Huynh Robbersmyr, Kjell G. Sensors (Basel) Article This paper aims to classify local demagnetisation and inter-turn short-circuit (ITSC) on position sensorless permanent magnet synchronous motors (PMSM) in transient states based on external stray flux and learning classifier. Within the framework, four supervised machine learning tools were tested: ensemble decision tree (EDT), k-nearest neighbours (KNN), support vector machine (SVM), and feedforward neural network (FNN). All algorithms are trained on datasets from one operational profile but tested on other different operation profiles. Their input features or spectrograms are computed from resampled time-series data based on the estimated position of the rotor from one stray flux sensor through an optimisation problem. This eliminates the need for the position sensors, allowing for the fault classification of sensorless PMSM drives using only two external stray flux sensors alone. Both SVM and FNN algorithms could identify a single fault of the magnet defect with an accuracy higher than 95% in transient states. For mixed faults, the FNN-based algorithm could identify ITSC in parallel-strands stator winding and local partial demagnetisation with an accuracy of 87.1%. MDPI 2022-02-05 /pmc/articles/PMC8839937/ /pubmed/35161959 http://dx.doi.org/10.3390/s22031216 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Attestog, Sveinung Senanayaka, Jagath Sri Lal Van Khang, Huynh Robbersmyr, Kjell G. Mixed Fault Classification of Sensorless PMSM Drive in Dynamic Operations Based on External Stray Flux Sensors |
title | Mixed Fault Classification of Sensorless PMSM Drive in Dynamic Operations Based on External Stray Flux Sensors |
title_full | Mixed Fault Classification of Sensorless PMSM Drive in Dynamic Operations Based on External Stray Flux Sensors |
title_fullStr | Mixed Fault Classification of Sensorless PMSM Drive in Dynamic Operations Based on External Stray Flux Sensors |
title_full_unstemmed | Mixed Fault Classification of Sensorless PMSM Drive in Dynamic Operations Based on External Stray Flux Sensors |
title_short | Mixed Fault Classification of Sensorless PMSM Drive in Dynamic Operations Based on External Stray Flux Sensors |
title_sort | mixed fault classification of sensorless pmsm drive in dynamic operations based on external stray flux sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8839937/ https://www.ncbi.nlm.nih.gov/pubmed/35161959 http://dx.doi.org/10.3390/s22031216 |
work_keys_str_mv | AT attestogsveinung mixedfaultclassificationofsensorlesspmsmdriveindynamicoperationsbasedonexternalstrayfluxsensors AT senanayakajagathsrilal mixedfaultclassificationofsensorlesspmsmdriveindynamicoperationsbasedonexternalstrayfluxsensors AT vankhanghuynh mixedfaultclassificationofsensorlesspmsmdriveindynamicoperationsbasedonexternalstrayfluxsensors AT robbersmyrkjellg mixedfaultclassificationofsensorlesspmsmdriveindynamicoperationsbasedonexternalstrayfluxsensors |