Cargando…
Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop
The existing analysis methods for the silicon gyroscope drive loop, such as the perturbation method and period average method, cannot analyze the dynamic characteristics of the system. In this work, a linearized amplitude control model of the silicon gyroscope drive loop was established to analyze t...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840161/ https://www.ncbi.nlm.nih.gov/pubmed/35161577 http://dx.doi.org/10.3390/s22030834 |
_version_ | 1784650550963339264 |
---|---|
author | Li, Qiang Ding, Lifeng Liu, Xiaowei Zhang, Qiang |
author_facet | Li, Qiang Ding, Lifeng Liu, Xiaowei Zhang, Qiang |
author_sort | Li, Qiang |
collection | PubMed |
description | The existing analysis methods for the silicon gyroscope drive loop, such as the perturbation method and period average method, cannot analyze the dynamic characteristics of the system. In this work, a linearized amplitude control model of the silicon gyroscope drive loop was established to analyze the stability and set-up time of the drive loop, and the vibration conditions of the silicon gyro were obtained. According to the above results, a new silicon gyroscope interface circuit was designed, using a 0.35 μm Bipolar-CMOS-DMOS (BCD) process, and the chip area was 4.5 mm × 4.0 mm. The application-specific integrated circuit (ASIC) of the silicon gyroscope was tested in combination with the sensitive structure with a zero stability of 1.14°/hr (Allen). The test results for the ASIC and the whole machine prove the correctness of the theoretical model, which reflects the effectiveness of the stability optimization of the closed-loop controlled drive loop of the silicon gyroscope circuit. |
format | Online Article Text |
id | pubmed-8840161 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-88401612022-02-13 Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop Li, Qiang Ding, Lifeng Liu, Xiaowei Zhang, Qiang Sensors (Basel) Article The existing analysis methods for the silicon gyroscope drive loop, such as the perturbation method and period average method, cannot analyze the dynamic characteristics of the system. In this work, a linearized amplitude control model of the silicon gyroscope drive loop was established to analyze the stability and set-up time of the drive loop, and the vibration conditions of the silicon gyro were obtained. According to the above results, a new silicon gyroscope interface circuit was designed, using a 0.35 μm Bipolar-CMOS-DMOS (BCD) process, and the chip area was 4.5 mm × 4.0 mm. The application-specific integrated circuit (ASIC) of the silicon gyroscope was tested in combination with the sensitive structure with a zero stability of 1.14°/hr (Allen). The test results for the ASIC and the whole machine prove the correctness of the theoretical model, which reflects the effectiveness of the stability optimization of the closed-loop controlled drive loop of the silicon gyroscope circuit. MDPI 2022-01-22 /pmc/articles/PMC8840161/ /pubmed/35161577 http://dx.doi.org/10.3390/s22030834 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Qiang Ding, Lifeng Liu, Xiaowei Zhang, Qiang Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop |
title | Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop |
title_full | Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop |
title_fullStr | Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop |
title_full_unstemmed | Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop |
title_short | Research on a Silicon Gyroscope Interface Circuit Based on Closed-Loop Controlled Drive Loop |
title_sort | research on a silicon gyroscope interface circuit based on closed-loop controlled drive loop |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840161/ https://www.ncbi.nlm.nih.gov/pubmed/35161577 http://dx.doi.org/10.3390/s22030834 |
work_keys_str_mv | AT liqiang researchonasilicongyroscopeinterfacecircuitbasedonclosedloopcontrolleddriveloop AT dinglifeng researchonasilicongyroscopeinterfacecircuitbasedonclosedloopcontrolleddriveloop AT liuxiaowei researchonasilicongyroscopeinterfacecircuitbasedonclosedloopcontrolleddriveloop AT zhangqiang researchonasilicongyroscopeinterfacecircuitbasedonclosedloopcontrolleddriveloop |