Liquid Level Sensor with Two FBGs Embedded in a PDMS Diaphragm: Analysis of the Linearity and Sensitivity

This paper presents a fiber optic, liquid level sensor system based on a pair of fiber Bragg gratings (FBGs), embedded in a circular silicone (PDMS—polydimethylsiloxane) rubber diaphragm. The measurement principles of this sensor, whose diaphragm structure is about 2.2 mm thick with 45 mm in diamete...

Descripción completa

Detalles Bibliográficos
Autores principales: Morais, Eliton, Pontes, Maria José, Marques, Carlos, Leal-Junior, Arnaldo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840254/
https://www.ncbi.nlm.nih.gov/pubmed/35162013
http://dx.doi.org/10.3390/s22031268
_version_ 1784650574906523648
author Morais, Eliton
Pontes, Maria José
Marques, Carlos
Leal-Junior, Arnaldo
author_facet Morais, Eliton
Pontes, Maria José
Marques, Carlos
Leal-Junior, Arnaldo
author_sort Morais, Eliton
collection PubMed
description This paper presents a fiber optic, liquid level sensor system based on a pair of fiber Bragg gratings (FBGs), embedded in a circular silicone (PDMS—polydimethylsiloxane) rubber diaphragm. The measurement principles of this sensor, whose diaphragm structure is about 2.2 mm thick with 45 mm in diameter, are introduced. To analyze the linearity and sensitivity of the sensor, the diaphragm was subjected to compression tests as well as to liquid level loading and unloading. The force and liquid level increase tests showed that inserting two FBGs (0.99453 for force and 0.99163 for liquid level) in the diaphragm resulted in a system with greater linearity than that with individual FBGs. This occurred where FBG1 showed 0.97684 for force and 0.98848 for liquid level and FBG2 presented 0.89461 for force and 0.93408 for liquid level. However, the compression and water level decrease tests showed that the system (R(2) = 0.97142) had greater linearity with FBG2 (0.94123) and lower linearity with FBG1 (0.98271). Temperature characterization was also performed, and we found that sensitivity to FBG1 temperature variation was 11.73 pm/°C and for FGB2 it was 10.29 pm/°C. Temperature sensitivity was improved for both FBGs when compared with uncoated FBGs with typical values of 9.75 pm/°C. Therefore, the proposed FBG-based sensor system is capable of simultaneous measurement of force and temperature in a compact diaphragm-embedded system.
format Online
Article
Text
id pubmed-8840254
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88402542022-02-13 Liquid Level Sensor with Two FBGs Embedded in a PDMS Diaphragm: Analysis of the Linearity and Sensitivity Morais, Eliton Pontes, Maria José Marques, Carlos Leal-Junior, Arnaldo Sensors (Basel) Article This paper presents a fiber optic, liquid level sensor system based on a pair of fiber Bragg gratings (FBGs), embedded in a circular silicone (PDMS—polydimethylsiloxane) rubber diaphragm. The measurement principles of this sensor, whose diaphragm structure is about 2.2 mm thick with 45 mm in diameter, are introduced. To analyze the linearity and sensitivity of the sensor, the diaphragm was subjected to compression tests as well as to liquid level loading and unloading. The force and liquid level increase tests showed that inserting two FBGs (0.99453 for force and 0.99163 for liquid level) in the diaphragm resulted in a system with greater linearity than that with individual FBGs. This occurred where FBG1 showed 0.97684 for force and 0.98848 for liquid level and FBG2 presented 0.89461 for force and 0.93408 for liquid level. However, the compression and water level decrease tests showed that the system (R(2) = 0.97142) had greater linearity with FBG2 (0.94123) and lower linearity with FBG1 (0.98271). Temperature characterization was also performed, and we found that sensitivity to FBG1 temperature variation was 11.73 pm/°C and for FGB2 it was 10.29 pm/°C. Temperature sensitivity was improved for both FBGs when compared with uncoated FBGs with typical values of 9.75 pm/°C. Therefore, the proposed FBG-based sensor system is capable of simultaneous measurement of force and temperature in a compact diaphragm-embedded system. MDPI 2022-02-07 /pmc/articles/PMC8840254/ /pubmed/35162013 http://dx.doi.org/10.3390/s22031268 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Morais, Eliton
Pontes, Maria José
Marques, Carlos
Leal-Junior, Arnaldo
Liquid Level Sensor with Two FBGs Embedded in a PDMS Diaphragm: Analysis of the Linearity and Sensitivity
title Liquid Level Sensor with Two FBGs Embedded in a PDMS Diaphragm: Analysis of the Linearity and Sensitivity
title_full Liquid Level Sensor with Two FBGs Embedded in a PDMS Diaphragm: Analysis of the Linearity and Sensitivity
title_fullStr Liquid Level Sensor with Two FBGs Embedded in a PDMS Diaphragm: Analysis of the Linearity and Sensitivity
title_full_unstemmed Liquid Level Sensor with Two FBGs Embedded in a PDMS Diaphragm: Analysis of the Linearity and Sensitivity
title_short Liquid Level Sensor with Two FBGs Embedded in a PDMS Diaphragm: Analysis of the Linearity and Sensitivity
title_sort liquid level sensor with two fbgs embedded in a pdms diaphragm: analysis of the linearity and sensitivity
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840254/
https://www.ncbi.nlm.nih.gov/pubmed/35162013
http://dx.doi.org/10.3390/s22031268
work_keys_str_mv AT moraiseliton liquidlevelsensorwithtwofbgsembeddedinapdmsdiaphragmanalysisofthelinearityandsensitivity
AT pontesmariajose liquidlevelsensorwithtwofbgsembeddedinapdmsdiaphragmanalysisofthelinearityandsensitivity
AT marquescarlos liquidlevelsensorwithtwofbgsembeddedinapdmsdiaphragmanalysisofthelinearityandsensitivity
AT lealjuniorarnaldo liquidlevelsensorwithtwofbgsembeddedinapdmsdiaphragmanalysisofthelinearityandsensitivity