Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?

OBJECTIVE: To compare the clinical results of homemade hook plates and hollow lag screws combined with spacers in the treatment of posterior cruciate tibial ligament avulsion fractures. MATERIALS AND METHODS: This was a retrospective clinical cohort study that included 64 patients with PCL tibial av...

Descripción completa

Detalles Bibliográficos
Autores principales: Qi, Hongfei, Lu, Yao, Li, Ming, Ren, Cheng, Xu, Yibo, Ma, Teng, Wang, Qian, Zhang, Kun, Li, Zhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840316/
https://www.ncbi.nlm.nih.gov/pubmed/35148737
http://dx.doi.org/10.1186/s12891-022-05096-0
_version_ 1784650589631676416
author Qi, Hongfei
Lu, Yao
Li, Ming
Ren, Cheng
Xu, Yibo
Ma, Teng
Wang, Qian
Zhang, Kun
Li, Zhong
author_facet Qi, Hongfei
Lu, Yao
Li, Ming
Ren, Cheng
Xu, Yibo
Ma, Teng
Wang, Qian
Zhang, Kun
Li, Zhong
author_sort Qi, Hongfei
collection PubMed
description OBJECTIVE: To compare the clinical results of homemade hook plates and hollow lag screws combined with spacers in the treatment of posterior cruciate tibial ligament avulsion fractures. MATERIALS AND METHODS: This was a retrospective clinical cohort study that included 64 patients with PCL tibial avulsion fractures. Thirty-two of them were fixed with a homemade hook plate (hook plate group), and 32 were fixed with a hollow lag screen combined with a gasket (hollow lag screen group). By reviewing the medical record data and follow-up results, the operation time, postoperative drainage, fracture healing time, surgical complications, knee mobility, recovery of joint function, and whether postoperative gastrocnemius muscle strength changed in the two groups were compared. RESULTS: All patients had successful wound and fracture healing. No adverse events, such as bone nonunion, infection, wound haematoma, or joint stiffness, occurred in either group. There were no patients with decreased gastrocnemius muscle strength in either group. Internal fixation failure occurred in 2 cases in the hollow lag screen group but not in the hook plate group. There were no significant differences between the two groups in terms of operative time, postoperative drainage, fracture healing time, knee mobility at the last follow-up, or Lysholm score. CONCLUSION: It is safe and effective to use a homemade hook plate to fix PCL tibial avulsion fractures through an inverted L-shaped posterior medial approach. A homemade hook plate may have potential advantages over a hollow lag screen combined with gasket fixation.
format Online
Article
Text
id pubmed-8840316
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-88403162022-02-16 Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate? Qi, Hongfei Lu, Yao Li, Ming Ren, Cheng Xu, Yibo Ma, Teng Wang, Qian Zhang, Kun Li, Zhong BMC Musculoskelet Disord Research OBJECTIVE: To compare the clinical results of homemade hook plates and hollow lag screws combined with spacers in the treatment of posterior cruciate tibial ligament avulsion fractures. MATERIALS AND METHODS: This was a retrospective clinical cohort study that included 64 patients with PCL tibial avulsion fractures. Thirty-two of them were fixed with a homemade hook plate (hook plate group), and 32 were fixed with a hollow lag screen combined with a gasket (hollow lag screen group). By reviewing the medical record data and follow-up results, the operation time, postoperative drainage, fracture healing time, surgical complications, knee mobility, recovery of joint function, and whether postoperative gastrocnemius muscle strength changed in the two groups were compared. RESULTS: All patients had successful wound and fracture healing. No adverse events, such as bone nonunion, infection, wound haematoma, or joint stiffness, occurred in either group. There were no patients with decreased gastrocnemius muscle strength in either group. Internal fixation failure occurred in 2 cases in the hollow lag screen group but not in the hook plate group. There were no significant differences between the two groups in terms of operative time, postoperative drainage, fracture healing time, knee mobility at the last follow-up, or Lysholm score. CONCLUSION: It is safe and effective to use a homemade hook plate to fix PCL tibial avulsion fractures through an inverted L-shaped posterior medial approach. A homemade hook plate may have potential advantages over a hollow lag screen combined with gasket fixation. BioMed Central 2022-02-11 /pmc/articles/PMC8840316/ /pubmed/35148737 http://dx.doi.org/10.1186/s12891-022-05096-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Qi, Hongfei
Lu, Yao
Li, Ming
Ren, Cheng
Xu, Yibo
Ma, Teng
Wang, Qian
Zhang, Kun
Li, Zhong
Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?
title Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?
title_full Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?
title_fullStr Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?
title_full_unstemmed Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?
title_short Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?
title_sort open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840316/
https://www.ncbi.nlm.nih.gov/pubmed/35148737
http://dx.doi.org/10.1186/s12891-022-05096-0
work_keys_str_mv AT qihongfei openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate
AT luyao openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate
AT liming openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate
AT rencheng openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate
AT xuyibo openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate
AT mateng openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate
AT wangqian openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate
AT zhangkun openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate
AT lizhong openreductionandinternalfixationofthetibialavulsionfractureoftheposteriorcruciateligamentwhichisbetterahollowlagscrewcombinedwithagasketorahomemadehookplate