Cargando…

Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening

Ambient ionization mass spectrometry has become one of the most promising approaches for rapid and high-throughput screening of small molecules in complex biological matrices for emergency medicine, forensics, and food and agriculture applications. The simple procedures for sample collection and ion...

Descripción completa

Detalles Bibliográficos
Autores principales: Shamraeva, Mariya A., Bormotov, Denis S., Shamarina, Ekaterina V., Bocharov, Konstantin V., Peregudova, Olga V., Pekov, Stanislav I., Nikolaev, Eugene N., Popov, Igor A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840626/
https://www.ncbi.nlm.nih.gov/pubmed/35164211
http://dx.doi.org/10.3390/molecules27030945
_version_ 1784650666717741056
author Shamraeva, Mariya A.
Bormotov, Denis S.
Shamarina, Ekaterina V.
Bocharov, Konstantin V.
Peregudova, Olga V.
Pekov, Stanislav I.
Nikolaev, Eugene N.
Popov, Igor A.
author_facet Shamraeva, Mariya A.
Bormotov, Denis S.
Shamarina, Ekaterina V.
Bocharov, Konstantin V.
Peregudova, Olga V.
Pekov, Stanislav I.
Nikolaev, Eugene N.
Popov, Igor A.
author_sort Shamraeva, Mariya A.
collection PubMed
description Ambient ionization mass spectrometry has become one of the most promising approaches for rapid and high-throughput screening of small molecules in complex biological matrices for emergency medicine, forensics, and food and agriculture applications. The simple procedures for sample collection and ionization without additional pretreatment are vital in these fields. Many efforts have been devoted to modifying various ambient ionization techniques to simplify the procedures and improve the robustness and sensitivity of the methods. Here, we demonstrate the implementation of rigid spherical sampler probes to improve the robustness of touch spray ionization mass spectrometry. The sphericity of the probes increases the stability of the cone-jet mode of electrospray, reduces the requirements for fine positioning of a sampler in the ion source, and decreases the possibility of corona discharge occurrence. The utilization of spherical sampler probes allows fast, non-invasive sampling, followed by rapid analysis for various drugs of different chemical classes in complex biological matrices, such as the whole blood or sebum collected from the skin surface. The linearity of the analytical signal response from drug concentration confirms the possibility of creating a simple semiquantitative method for small molecules monitoring using spherical sampler probes.
format Online
Article
Text
id pubmed-8840626
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-88406262022-02-13 Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening Shamraeva, Mariya A. Bormotov, Denis S. Shamarina, Ekaterina V. Bocharov, Konstantin V. Peregudova, Olga V. Pekov, Stanislav I. Nikolaev, Eugene N. Popov, Igor A. Molecules Article Ambient ionization mass spectrometry has become one of the most promising approaches for rapid and high-throughput screening of small molecules in complex biological matrices for emergency medicine, forensics, and food and agriculture applications. The simple procedures for sample collection and ionization without additional pretreatment are vital in these fields. Many efforts have been devoted to modifying various ambient ionization techniques to simplify the procedures and improve the robustness and sensitivity of the methods. Here, we demonstrate the implementation of rigid spherical sampler probes to improve the robustness of touch spray ionization mass spectrometry. The sphericity of the probes increases the stability of the cone-jet mode of electrospray, reduces the requirements for fine positioning of a sampler in the ion source, and decreases the possibility of corona discharge occurrence. The utilization of spherical sampler probes allows fast, non-invasive sampling, followed by rapid analysis for various drugs of different chemical classes in complex biological matrices, such as the whole blood or sebum collected from the skin surface. The linearity of the analytical signal response from drug concentration confirms the possibility of creating a simple semiquantitative method for small molecules monitoring using spherical sampler probes. MDPI 2022-01-30 /pmc/articles/PMC8840626/ /pubmed/35164211 http://dx.doi.org/10.3390/molecules27030945 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shamraeva, Mariya A.
Bormotov, Denis S.
Shamarina, Ekaterina V.
Bocharov, Konstantin V.
Peregudova, Olga V.
Pekov, Stanislav I.
Nikolaev, Eugene N.
Popov, Igor A.
Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening
title Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening
title_full Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening
title_fullStr Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening
title_full_unstemmed Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening
title_short Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening
title_sort spherical sampler probes enhance the robustness of ambient ionization mass spectrometry for rapid drugs screening
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8840626/
https://www.ncbi.nlm.nih.gov/pubmed/35164211
http://dx.doi.org/10.3390/molecules27030945
work_keys_str_mv AT shamraevamariyaa sphericalsamplerprobesenhancetherobustnessofambientionizationmassspectrometryforrapiddrugsscreening
AT bormotovdeniss sphericalsamplerprobesenhancetherobustnessofambientionizationmassspectrometryforrapiddrugsscreening
AT shamarinaekaterinav sphericalsamplerprobesenhancetherobustnessofambientionizationmassspectrometryforrapiddrugsscreening
AT bocharovkonstantinv sphericalsamplerprobesenhancetherobustnessofambientionizationmassspectrometryforrapiddrugsscreening
AT peregudovaolgav sphericalsamplerprobesenhancetherobustnessofambientionizationmassspectrometryforrapiddrugsscreening
AT pekovstanislavi sphericalsamplerprobesenhancetherobustnessofambientionizationmassspectrometryforrapiddrugsscreening
AT nikolaeveugenen sphericalsamplerprobesenhancetherobustnessofambientionizationmassspectrometryforrapiddrugsscreening
AT popovigora sphericalsamplerprobesenhancetherobustnessofambientionizationmassspectrometryforrapiddrugsscreening