Clinical predictors and electrodiagnostic characteristics in patients with Guillain-Barré syndrome with respiratory failure: a retrospective, matched case-control study
BACKGROUND: Respiratory failure is a common complication of Guillain-Barré syndrome (GBS). This study aimed to determine the clinical predictors and electrodiagnostic (EDx) characteristics in patients with Guillain-Barré syndrome (GBS) with respiratory failure. METHODS: The retrospective study inclu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8841033/ https://www.ncbi.nlm.nih.gov/pubmed/35186497 http://dx.doi.org/10.7717/peerj.12930 |
_version_ | 1784650748852699136 |
---|---|
author | Charoentanyarak, Kanchana Singjam, Apiradee Saengsuwan, Jittima |
author_facet | Charoentanyarak, Kanchana Singjam, Apiradee Saengsuwan, Jittima |
author_sort | Charoentanyarak, Kanchana |
collection | PubMed |
description | BACKGROUND: Respiratory failure is a common complication of Guillain-Barré syndrome (GBS). This study aimed to determine the clinical predictors and electrodiagnostic (EDx) characteristics in patients with Guillain-Barré syndrome (GBS) with respiratory failure. METHODS: The retrospective study included 29 confirmed GBS cases with respiratory failure and age- (±5 years) and sex-matched controls (1:1). The dependent t-test and McNemar–Bowker test were used to analyse the continuous and categorical data, respectively. In addition, a multiple logistic regression analysis was used to analyse the predictive factors for respiratory failure. RESULTS: Among both cases and controls, the majority were male (72.4%), and the average age was 50.9 years. The data showed that patients with respiratory failure had higher GBS disability scores, lower motor power (≤3) of the hip flexors and ankle dorsiflexors, and experienced facial and bulbar palsy. In the multivariate analysis, the significant predictive factors were bulbar palsy (AOR 10.4 [95% CI [2.6–41.4]) and motor power of hip flexors ≤ 3 (AOR 31.4 [95% CI [3.1–314.5]). Patients with respiratory failure had lower compound muscle action potential amplitude of the ulnar and tibial nerves. The median, ulnar, and tibial nerve conduction studies were more likely to reflect inexcitability. The GBS subtypes in GBS patients with and without respiratory failure were not significantly different. CONCLUSIONS: Bulbar palsy and motor power of the hip flexors ≤ 3 were significant predictors for respiratory failure. The GBS subtypes in patients with and without respiratory failure were not significantly different. |
format | Online Article Text |
id | pubmed-8841033 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88410332022-02-17 Clinical predictors and electrodiagnostic characteristics in patients with Guillain-Barré syndrome with respiratory failure: a retrospective, matched case-control study Charoentanyarak, Kanchana Singjam, Apiradee Saengsuwan, Jittima PeerJ Epidemiology BACKGROUND: Respiratory failure is a common complication of Guillain-Barré syndrome (GBS). This study aimed to determine the clinical predictors and electrodiagnostic (EDx) characteristics in patients with Guillain-Barré syndrome (GBS) with respiratory failure. METHODS: The retrospective study included 29 confirmed GBS cases with respiratory failure and age- (±5 years) and sex-matched controls (1:1). The dependent t-test and McNemar–Bowker test were used to analyse the continuous and categorical data, respectively. In addition, a multiple logistic regression analysis was used to analyse the predictive factors for respiratory failure. RESULTS: Among both cases and controls, the majority were male (72.4%), and the average age was 50.9 years. The data showed that patients with respiratory failure had higher GBS disability scores, lower motor power (≤3) of the hip flexors and ankle dorsiflexors, and experienced facial and bulbar palsy. In the multivariate analysis, the significant predictive factors were bulbar palsy (AOR 10.4 [95% CI [2.6–41.4]) and motor power of hip flexors ≤ 3 (AOR 31.4 [95% CI [3.1–314.5]). Patients with respiratory failure had lower compound muscle action potential amplitude of the ulnar and tibial nerves. The median, ulnar, and tibial nerve conduction studies were more likely to reflect inexcitability. The GBS subtypes in GBS patients with and without respiratory failure were not significantly different. CONCLUSIONS: Bulbar palsy and motor power of the hip flexors ≤ 3 were significant predictors for respiratory failure. The GBS subtypes in patients with and without respiratory failure were not significantly different. PeerJ Inc. 2022-02-10 /pmc/articles/PMC8841033/ /pubmed/35186497 http://dx.doi.org/10.7717/peerj.12930 Text en ©2022 Charoentanyarak et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Epidemiology Charoentanyarak, Kanchana Singjam, Apiradee Saengsuwan, Jittima Clinical predictors and electrodiagnostic characteristics in patients with Guillain-Barré syndrome with respiratory failure: a retrospective, matched case-control study |
title | Clinical predictors and electrodiagnostic characteristics in patients with Guillain-Barré syndrome with respiratory failure: a retrospective, matched case-control study |
title_full | Clinical predictors and electrodiagnostic characteristics in patients with Guillain-Barré syndrome with respiratory failure: a retrospective, matched case-control study |
title_fullStr | Clinical predictors and electrodiagnostic characteristics in patients with Guillain-Barré syndrome with respiratory failure: a retrospective, matched case-control study |
title_full_unstemmed | Clinical predictors and electrodiagnostic characteristics in patients with Guillain-Barré syndrome with respiratory failure: a retrospective, matched case-control study |
title_short | Clinical predictors and electrodiagnostic characteristics in patients with Guillain-Barré syndrome with respiratory failure: a retrospective, matched case-control study |
title_sort | clinical predictors and electrodiagnostic characteristics in patients with guillain-barré syndrome with respiratory failure: a retrospective, matched case-control study |
topic | Epidemiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8841033/ https://www.ncbi.nlm.nih.gov/pubmed/35186497 http://dx.doi.org/10.7717/peerj.12930 |
work_keys_str_mv | AT charoentanyarakkanchana clinicalpredictorsandelectrodiagnosticcharacteristicsinpatientswithguillainbarresyndromewithrespiratoryfailurearetrospectivematchedcasecontrolstudy AT singjamapiradee clinicalpredictorsandelectrodiagnosticcharacteristicsinpatientswithguillainbarresyndromewithrespiratoryfailurearetrospectivematchedcasecontrolstudy AT saengsuwanjittima clinicalpredictorsandelectrodiagnosticcharacteristicsinpatientswithguillainbarresyndromewithrespiratoryfailurearetrospectivematchedcasecontrolstudy |