Cargando…

Short-term effects of two types of goggles on intraocular pressure and anterior eye segment biometrics

BACKGROUND: To evaluate and compare the changes in intraocular pressure and anterior eye segment biometrics during and after wearing two types of commonly used swimming goggles. METHODS: In a cross-sectional study, a total of 40 healthy adults aged between 18 and 60 years old were selected to wear t...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xu, Wang, Huixian, Nie, Yuan, Li, Wenjing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8841071/
https://www.ncbi.nlm.nih.gov/pubmed/35151279
http://dx.doi.org/10.1186/s12886-022-02308-y
Descripción
Sumario:BACKGROUND: To evaluate and compare the changes in intraocular pressure and anterior eye segment biometrics during and after wearing two types of commonly used swimming goggles. METHODS: In a cross-sectional study, a total of 40 healthy adults aged between 18 and 60 years old were selected to wear two kinds of common swimming goggles (ocular socket and orbital goggles). Intraocular pressure and anterior segment biometry were evaluated before wearing, at 2 and 5 min of wearing, and at 5 min after removing the goggles. Intraocular pressure (IOP), corneal front keratometry values (K1, K2, Km), central corneal thickness (CCT), central anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) were measured. RESULTS: The IOP at 2 min (21.0 ± 2.2 mmHg) and 5 min (21.2 ± 2.3 mmHg) was significantly higher than before wearing goggles (17.7 ± 2.1 mmHg). The IOP after the goggles were removed and at 5 min after the goggles were removed was 18.4 ± 2.3 mmHg and 17.7 ± 2.1 mmHg, respectively. ACV, ACD, and ACA values all decreased while the googles were worn. After the goggles were removed, these changes gradually returned to baseline values, with no significant difference in the values before and after. CONCLUSION: This study proves that wearing orbital goggles can lead to an acute increase in IOP and a slight decrease in ACV, ACD, and ACA. However, once the goggles are removed, these indicators return to baseline levels, showing that wearing orbital goggles has no significant lasting effect on IOP and anterior segment parameters. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02308-y.