Cargando…

Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve

BACKGROUND: There is no evidence of hemodynamic performance during exercise in patients with aortic stenosis (AS) after transcatheter aortic valve implantation (TAVI). This study aimed to investigate the changes in kinematic hemodynamics during exercise and determine the impact of prosthesis-patient...

Descripción completa

Detalles Bibliográficos
Autores principales: Kameshima, Haruka, Izumo, Masaki, Suzuki, Tomomi, Ohara, Hiroshi, Sato, Yukio, Watanabe, Mika, Kuwata, Shingo, Okuyama, Kazuaki, Kamijima, Ryo, Takai, Manabu, Kou, Seisyou, Tanabe, Yasuhiro, Harada, Tomoo, Akashi, Yoshihiro J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8841769/
https://www.ncbi.nlm.nih.gov/pubmed/35174223
http://dx.doi.org/10.3389/fcvm.2021.799285
_version_ 1784650910256857088
author Kameshima, Haruka
Izumo, Masaki
Suzuki, Tomomi
Ohara, Hiroshi
Sato, Yukio
Watanabe, Mika
Kuwata, Shingo
Okuyama, Kazuaki
Kamijima, Ryo
Takai, Manabu
Kou, Seisyou
Tanabe, Yasuhiro
Harada, Tomoo
Akashi, Yoshihiro J.
author_facet Kameshima, Haruka
Izumo, Masaki
Suzuki, Tomomi
Ohara, Hiroshi
Sato, Yukio
Watanabe, Mika
Kuwata, Shingo
Okuyama, Kazuaki
Kamijima, Ryo
Takai, Manabu
Kou, Seisyou
Tanabe, Yasuhiro
Harada, Tomoo
Akashi, Yoshihiro J.
author_sort Kameshima, Haruka
collection PubMed
description BACKGROUND: There is no evidence of hemodynamic performance during exercise in patients with aortic stenosis (AS) after transcatheter aortic valve implantation (TAVI). This study aimed to investigate the changes in kinematic hemodynamics during exercise and determine the impact of prosthesis-patient mismatch (PPM) on the hemodynamics of transcatheter heart valves using exercise stress echocardiography (ESE) in AS patients after TAVI. METHODS AND RESULTS: This study enrolled 77 consecutive patients (mean age 82 ± 5 years, 50.6% male) who underwent ESE 3–6 months after TAVI with a balloon-expandable valve. The effective orifice area index at rest was significantly correlated with the mean pressure gradient (PG) during exercise (p <0.001). The patients were divided into two groups according to the presence of PPM (PPM and non-PPM groups). During exercise, the patients with PPM had a higher left ventricular ejection fraction (74.6 ± 6.1% vs. 69.7 ± 9.6%, p = 0.048), a lower stroke volume index (47.2 ± 14.0 ml/m(2) vs. 55.6 ± 14.5 ml/m(2), p = 0.037), a significantly higher mean transvalvular PG (21.9 ± 9.1 mmHg vs. 12.2 ± 4.9 mmHg, p = 0.01) and an increased mean PG from rest to exercise (5.7 ± 3.5 mmHg vs. 2.3 ± 2.8 mmHg, p <0.001) compared with patients without PPM. Patients with PPM had a higher pulmonary artery systolic pressure (SPAP) during exercise (57.3 ± 13.8 mmHg vs. 49.7 ± 10.9 mmHg, p = 0.021) and a higher incidence of exercise-induced pulmonary hypertension (43.8 vs. 15.0%, p = 0.037) than patients without PPM. PPM was strongly associated with exercise-induced pulmonary hypertension (hazard ratio: 3.570, p = 0.013). CONCLUSIONS: AS patients with PPM after TAVI showed a disproportionate increase in the transvalvular PG and SPAP during exercise, and PPM was associated with exercise-induced pulmonary hypertension.
format Online
Article
Text
id pubmed-8841769
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-88417692022-02-15 Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve Kameshima, Haruka Izumo, Masaki Suzuki, Tomomi Ohara, Hiroshi Sato, Yukio Watanabe, Mika Kuwata, Shingo Okuyama, Kazuaki Kamijima, Ryo Takai, Manabu Kou, Seisyou Tanabe, Yasuhiro Harada, Tomoo Akashi, Yoshihiro J. Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: There is no evidence of hemodynamic performance during exercise in patients with aortic stenosis (AS) after transcatheter aortic valve implantation (TAVI). This study aimed to investigate the changes in kinematic hemodynamics during exercise and determine the impact of prosthesis-patient mismatch (PPM) on the hemodynamics of transcatheter heart valves using exercise stress echocardiography (ESE) in AS patients after TAVI. METHODS AND RESULTS: This study enrolled 77 consecutive patients (mean age 82 ± 5 years, 50.6% male) who underwent ESE 3–6 months after TAVI with a balloon-expandable valve. The effective orifice area index at rest was significantly correlated with the mean pressure gradient (PG) during exercise (p <0.001). The patients were divided into two groups according to the presence of PPM (PPM and non-PPM groups). During exercise, the patients with PPM had a higher left ventricular ejection fraction (74.6 ± 6.1% vs. 69.7 ± 9.6%, p = 0.048), a lower stroke volume index (47.2 ± 14.0 ml/m(2) vs. 55.6 ± 14.5 ml/m(2), p = 0.037), a significantly higher mean transvalvular PG (21.9 ± 9.1 mmHg vs. 12.2 ± 4.9 mmHg, p = 0.01) and an increased mean PG from rest to exercise (5.7 ± 3.5 mmHg vs. 2.3 ± 2.8 mmHg, p <0.001) compared with patients without PPM. Patients with PPM had a higher pulmonary artery systolic pressure (SPAP) during exercise (57.3 ± 13.8 mmHg vs. 49.7 ± 10.9 mmHg, p = 0.021) and a higher incidence of exercise-induced pulmonary hypertension (43.8 vs. 15.0%, p = 0.037) than patients without PPM. PPM was strongly associated with exercise-induced pulmonary hypertension (hazard ratio: 3.570, p = 0.013). CONCLUSIONS: AS patients with PPM after TAVI showed a disproportionate increase in the transvalvular PG and SPAP during exercise, and PPM was associated with exercise-induced pulmonary hypertension. Frontiers Media S.A. 2022-01-31 /pmc/articles/PMC8841769/ /pubmed/35174223 http://dx.doi.org/10.3389/fcvm.2021.799285 Text en Copyright © 2022 Kameshima, Izumo, Suzuki, Ohara, Sato, Watanabe, Kuwata, Okuyama, Kamijima, Takai, Kou, Tanabe, Harada and Akashi. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Kameshima, Haruka
Izumo, Masaki
Suzuki, Tomomi
Ohara, Hiroshi
Sato, Yukio
Watanabe, Mika
Kuwata, Shingo
Okuyama, Kazuaki
Kamijima, Ryo
Takai, Manabu
Kou, Seisyou
Tanabe, Yasuhiro
Harada, Tomoo
Akashi, Yoshihiro J.
Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
title Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
title_full Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
title_fullStr Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
title_full_unstemmed Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
title_short Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
title_sort impact of prosthesis-patient mismatch on hemodynamics during exercise in patients with aortic stenosis after transcatheter aortic valve implantation with a balloon-expandable valve
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8841769/
https://www.ncbi.nlm.nih.gov/pubmed/35174223
http://dx.doi.org/10.3389/fcvm.2021.799285
work_keys_str_mv AT kameshimaharuka impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT izumomasaki impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT suzukitomomi impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT oharahiroshi impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT satoyukio impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT watanabemika impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT kuwatashingo impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT okuyamakazuaki impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT kamijimaryo impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT takaimanabu impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT kouseisyou impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT tanabeyasuhiro impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT haradatomoo impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve
AT akashiyoshihiroj impactofprosthesispatientmismatchonhemodynamicsduringexerciseinpatientswithaorticstenosisaftertranscatheteraorticvalveimplantationwithaballoonexpandablevalve