Simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study

The high sensitivity of the methods applied in breath analysis entails a high risk of detecting analytes that do not derive from endogenous production. Consequentially, it appears useful to have knowledge about the composition of inhaled air and to include alveolar gradients into interpretation. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Westhoff, Michael, Friedrich, Maren, Baumbach, Jörg I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Respiratory Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8841987/
https://www.ncbi.nlm.nih.gov/pubmed/35174246
http://dx.doi.org/10.1183/23120541.00493-2021
_version_ 1784650960173268992
author Westhoff, Michael
Friedrich, Maren
Baumbach, Jörg I.
author_facet Westhoff, Michael
Friedrich, Maren
Baumbach, Jörg I.
author_sort Westhoff, Michael
collection PubMed
description The high sensitivity of the methods applied in breath analysis entails a high risk of detecting analytes that do not derive from endogenous production. Consequentially, it appears useful to have knowledge about the composition of inhaled air and to include alveolar gradients into interpretation. The current study aimed to standardise sampling procedures in breath analysis, especially with multicapillary column ion-mobility spectrometry (MCC-IMS), by applying a simultaneous registration of inhaled air and exhaled breath. A “double MCC-IMS” device, which for the first time allows simultaneous analysis of inhaled air and exhaled breath, was developed and tested in 18 healthy individuals. For this, two BreathDiscovery instruments were coupled with each other. Measurements of inhaled air and exhaled breath in 18 healthy individuals (mean age 46±10.9 years; nine men, nine women) identified 35 different volatile organic compounds (VOCs) for further analysis. Not all of these had positive alveolar gradients and could be regarded as endogenous VOCs: 16 VOCs had a positive alveolar gradient in mean; 19 VOCs a negative one. 12 VOCs were positive in >12 of the healthy subjects. For the first time in our understanding, a method is described that enables simultaneous measurement of inhaled air and exhaled breath. This facilitates the calculation of alveolar gradients and selection of endogenous VOCs for exhaled breath analysis. Only a part of VOCs in exhaled breath are truly endogenous VOCs. The observation of different and varying polarities of the alveolar gradients needs further analysis.
format Online
Article
Text
id pubmed-8841987
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher European Respiratory Society
record_format MEDLINE/PubMed
spelling pubmed-88419872022-02-15 Simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study Westhoff, Michael Friedrich, Maren Baumbach, Jörg I. ERJ Open Res Original Research Articles The high sensitivity of the methods applied in breath analysis entails a high risk of detecting analytes that do not derive from endogenous production. Consequentially, it appears useful to have knowledge about the composition of inhaled air and to include alveolar gradients into interpretation. The current study aimed to standardise sampling procedures in breath analysis, especially with multicapillary column ion-mobility spectrometry (MCC-IMS), by applying a simultaneous registration of inhaled air and exhaled breath. A “double MCC-IMS” device, which for the first time allows simultaneous analysis of inhaled air and exhaled breath, was developed and tested in 18 healthy individuals. For this, two BreathDiscovery instruments were coupled with each other. Measurements of inhaled air and exhaled breath in 18 healthy individuals (mean age 46±10.9 years; nine men, nine women) identified 35 different volatile organic compounds (VOCs) for further analysis. Not all of these had positive alveolar gradients and could be regarded as endogenous VOCs: 16 VOCs had a positive alveolar gradient in mean; 19 VOCs a negative one. 12 VOCs were positive in >12 of the healthy subjects. For the first time in our understanding, a method is described that enables simultaneous measurement of inhaled air and exhaled breath. This facilitates the calculation of alveolar gradients and selection of endogenous VOCs for exhaled breath analysis. Only a part of VOCs in exhaled breath are truly endogenous VOCs. The observation of different and varying polarities of the alveolar gradients needs further analysis. European Respiratory Society 2022-02-14 /pmc/articles/PMC8841987/ /pubmed/35174246 http://dx.doi.org/10.1183/23120541.00493-2021 Text en Copyright ©The authors 2022 https://creativecommons.org/licenses/by-nc/4.0/This version is distributed under the terms of the Creative Commons Attribution Non-Commercial Licence 4.0. For commercial reproduction rights and permissions contact permissions@ersnet.org (mailto:permissions@ersnet.org)
spellingShingle Original Research Articles
Westhoff, Michael
Friedrich, Maren
Baumbach, Jörg I.
Simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study
title Simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study
title_full Simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study
title_fullStr Simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study
title_full_unstemmed Simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study
title_short Simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study
title_sort simultaneous measurement of inhaled air and exhaled breath by double multicapillary column ion-mobility spectrometry, a new method for breath analysis: results of a feasibility study
topic Original Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8841987/
https://www.ncbi.nlm.nih.gov/pubmed/35174246
http://dx.doi.org/10.1183/23120541.00493-2021
work_keys_str_mv AT westhoffmichael simultaneousmeasurementofinhaledairandexhaledbreathbydoublemulticapillarycolumnionmobilityspectrometryanewmethodforbreathanalysisresultsofafeasibilitystudy
AT friedrichmaren simultaneousmeasurementofinhaledairandexhaledbreathbydoublemulticapillarycolumnionmobilityspectrometryanewmethodforbreathanalysisresultsofafeasibilitystudy
AT baumbachjorgi simultaneousmeasurementofinhaledairandexhaledbreathbydoublemulticapillarycolumnionmobilityspectrometryanewmethodforbreathanalysisresultsofafeasibilitystudy