Cargando…

Macular Choroidal Thickness in Patients with Ocular Hypertension as Assessed Using Enhanced Depth Imaging Optical Coherence Tomography

OBJECTIVES: The aim of this study was to evaluate the macular choroidal thickness (CT) in patients with ocular hypertension (OHT) using spectral domain optical coherence tomography (SD-OCT) and compare the results with healthy individuals. METHODS: Thirty eyes of 30 patients newly diagnosed with OHT...

Descripción completa

Detalles Bibliográficos
Autores principales: Yilmaz, Pinar Topcu, Koz, Ozlem Gurbuz, Yarangumeli, Alper, Alp, Mehmet Numan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8842051/
https://www.ncbi.nlm.nih.gov/pubmed/35187440
http://dx.doi.org/10.14744/bej.2019.96268
_version_ 1784650976246890496
author Yilmaz, Pinar Topcu
Koz, Ozlem Gurbuz
Yarangumeli, Alper
Alp, Mehmet Numan
author_facet Yilmaz, Pinar Topcu
Koz, Ozlem Gurbuz
Yarangumeli, Alper
Alp, Mehmet Numan
author_sort Yilmaz, Pinar Topcu
collection PubMed
description OBJECTIVES: The aim of this study was to evaluate the macular choroidal thickness (CT) in patients with ocular hypertension (OHT) using spectral domain optical coherence tomography (SD-OCT) and compare the results with healthy individuals. METHODS: Thirty eyes of 30 patients newly diagnosed with OHT and 24 eyes of 24 healthy controls were included in this cross-sectional study. After a detailed ophthalmological examination, macular CT was measured with enhanced depth imaging optical coherence tomography (EDI-OCT) (Cirrus HD-OCT, Carl Zeiss Meditec AG, Jena, Germany) at the fovea and at positions 500 μ, 1000 μ, 1500 μ nasal and temporal to the fovea. The Mann-Whitney U test was used to compare the CT measurements between groups. The correlation between the mean deviation, pattern standard deviation, and retinal nerve fiber layer thickness (RNFL) and CT was evaluated with the Spearman correlation coefficient. Statistical significance was accepted as p<0.05. RESULTS: The mean CT in the OHT group was significantly thinner than that of the controls at locations 1000 μ (250.13±69.53μ vs 275.92±47.34μ; p=0.02) and 1500μ (236.03±65.44μ vs 265.46±47.56μ; p=0.009) temporal to the fovea. The CT at the other measurement points was also thinner in eyes with OHT, but the difference failed to reach statistical significance. A moderately negative correlation was detected between the mean deviation and CT at locations 1000μ (r=-0.42; p=0.03) and 1500μ (r=-0.44; p=0.02) temporal to the fovea There was a moderate correlation between the average RNFL thickness and CT at locations 500μ (r=0.44; p=0.03), 1000μ (r=0.42; p=0.04) and 1500μ (r=0.56; p=0.005) temporal to the fovea. CONCLUSION: In the present study, the macular CT was thinner in patients with OHT and this thinning was statistically significant at the temporal macula. A longitudinal, prospective study involving multiple EDI-OCT measurements is required to further understand the relationship.
format Online
Article
Text
id pubmed-8842051
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Kare Publishing
record_format MEDLINE/PubMed
spelling pubmed-88420512022-02-18 Macular Choroidal Thickness in Patients with Ocular Hypertension as Assessed Using Enhanced Depth Imaging Optical Coherence Tomography Yilmaz, Pinar Topcu Koz, Ozlem Gurbuz Yarangumeli, Alper Alp, Mehmet Numan Beyoglu Eye J Original Article OBJECTIVES: The aim of this study was to evaluate the macular choroidal thickness (CT) in patients with ocular hypertension (OHT) using spectral domain optical coherence tomography (SD-OCT) and compare the results with healthy individuals. METHODS: Thirty eyes of 30 patients newly diagnosed with OHT and 24 eyes of 24 healthy controls were included in this cross-sectional study. After a detailed ophthalmological examination, macular CT was measured with enhanced depth imaging optical coherence tomography (EDI-OCT) (Cirrus HD-OCT, Carl Zeiss Meditec AG, Jena, Germany) at the fovea and at positions 500 μ, 1000 μ, 1500 μ nasal and temporal to the fovea. The Mann-Whitney U test was used to compare the CT measurements between groups. The correlation between the mean deviation, pattern standard deviation, and retinal nerve fiber layer thickness (RNFL) and CT was evaluated with the Spearman correlation coefficient. Statistical significance was accepted as p<0.05. RESULTS: The mean CT in the OHT group was significantly thinner than that of the controls at locations 1000 μ (250.13±69.53μ vs 275.92±47.34μ; p=0.02) and 1500μ (236.03±65.44μ vs 265.46±47.56μ; p=0.009) temporal to the fovea. The CT at the other measurement points was also thinner in eyes with OHT, but the difference failed to reach statistical significance. A moderately negative correlation was detected between the mean deviation and CT at locations 1000μ (r=-0.42; p=0.03) and 1500μ (r=-0.44; p=0.02) temporal to the fovea There was a moderate correlation between the average RNFL thickness and CT at locations 500μ (r=0.44; p=0.03), 1000μ (r=0.42; p=0.04) and 1500μ (r=0.56; p=0.005) temporal to the fovea. CONCLUSION: In the present study, the macular CT was thinner in patients with OHT and this thinning was statistically significant at the temporal macula. A longitudinal, prospective study involving multiple EDI-OCT measurements is required to further understand the relationship. Kare Publishing 2017-08-05 /pmc/articles/PMC8842051/ /pubmed/35187440 http://dx.doi.org/10.14744/bej.2019.96268 Text en Copyright: © 2019 by Beyoglu Eye Training and Research Hospital https://creativecommons.org/licenses/by-nc-sa/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
spellingShingle Original Article
Yilmaz, Pinar Topcu
Koz, Ozlem Gurbuz
Yarangumeli, Alper
Alp, Mehmet Numan
Macular Choroidal Thickness in Patients with Ocular Hypertension as Assessed Using Enhanced Depth Imaging Optical Coherence Tomography
title Macular Choroidal Thickness in Patients with Ocular Hypertension as Assessed Using Enhanced Depth Imaging Optical Coherence Tomography
title_full Macular Choroidal Thickness in Patients with Ocular Hypertension as Assessed Using Enhanced Depth Imaging Optical Coherence Tomography
title_fullStr Macular Choroidal Thickness in Patients with Ocular Hypertension as Assessed Using Enhanced Depth Imaging Optical Coherence Tomography
title_full_unstemmed Macular Choroidal Thickness in Patients with Ocular Hypertension as Assessed Using Enhanced Depth Imaging Optical Coherence Tomography
title_short Macular Choroidal Thickness in Patients with Ocular Hypertension as Assessed Using Enhanced Depth Imaging Optical Coherence Tomography
title_sort macular choroidal thickness in patients with ocular hypertension as assessed using enhanced depth imaging optical coherence tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8842051/
https://www.ncbi.nlm.nih.gov/pubmed/35187440
http://dx.doi.org/10.14744/bej.2019.96268
work_keys_str_mv AT yilmazpinartopcu macularchoroidalthicknessinpatientswithocularhypertensionasassessedusingenhanceddepthimagingopticalcoherencetomography
AT kozozlemgurbuz macularchoroidalthicknessinpatientswithocularhypertensionasassessedusingenhanceddepthimagingopticalcoherencetomography
AT yarangumelialper macularchoroidalthicknessinpatientswithocularhypertensionasassessedusingenhanceddepthimagingopticalcoherencetomography
AT alpmehmetnuman macularchoroidalthicknessinpatientswithocularhypertensionasassessedusingenhanceddepthimagingopticalcoherencetomography