Cargando…
Analytical performance evaluation of different test systems on serum creatinine assay
BACKGROUND: Serum creatinine (SCr) is a useful diagnostic marker for the assessment of renal function. Accurate quantitation of SCr is clinically important in calculation of glomerular filtration rate (GFR). METHOD: To confirm whether there are differences in SCr between enzymatic kits of different...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8842161/ https://www.ncbi.nlm.nih.gov/pubmed/34957600 http://dx.doi.org/10.1002/jcla.24206 |
_version_ | 1784650995934953472 |
---|---|
author | He, Lina Yu, Jinqi Han, Guang Huang, Di Han, Liqiao Zhang, Qiaoxuan Wang, Yunxiu Wan, Zemin Huang, Xian‐Zhang Xiong, Yujuan Wu, Xiaobin |
author_facet | He, Lina Yu, Jinqi Han, Guang Huang, Di Han, Liqiao Zhang, Qiaoxuan Wang, Yunxiu Wan, Zemin Huang, Xian‐Zhang Xiong, Yujuan Wu, Xiaobin |
author_sort | He, Lina |
collection | PubMed |
description | BACKGROUND: Serum creatinine (SCr) is a useful diagnostic marker for the assessment of renal function. Accurate quantitation of SCr is clinically important in calculation of glomerular filtration rate (GFR). METHOD: To confirm whether there are differences in SCr between enzymatic kits of different manufacturers, the analytical performance of the matched and open test system in the measurement of SCr was evaluated. The analytical performance evaluation was conducted according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Precision, accuracy, linearity, dilution, lower limit of measurement and analytical interference were studied between the two test systems. RESULTS: The performance of SCr from the open test system was in compliance with the matched test system with good precision, accuracy, and linearity. In presence of most common interferents, both test systems could lead to accurate creatinine results except for the existence of specified drugs. For dobutamine, the open test system showed better anti‐interference performance than the matched system. CONCLUSION: This study provides referable opinions for clinical laboratory selection on the test system and a framework for future analogous studies based on different test systems. |
format | Online Article Text |
id | pubmed-8842161 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88421612022-02-22 Analytical performance evaluation of different test systems on serum creatinine assay He, Lina Yu, Jinqi Han, Guang Huang, Di Han, Liqiao Zhang, Qiaoxuan Wang, Yunxiu Wan, Zemin Huang, Xian‐Zhang Xiong, Yujuan Wu, Xiaobin J Clin Lab Anal Research Articles BACKGROUND: Serum creatinine (SCr) is a useful diagnostic marker for the assessment of renal function. Accurate quantitation of SCr is clinically important in calculation of glomerular filtration rate (GFR). METHOD: To confirm whether there are differences in SCr between enzymatic kits of different manufacturers, the analytical performance of the matched and open test system in the measurement of SCr was evaluated. The analytical performance evaluation was conducted according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Precision, accuracy, linearity, dilution, lower limit of measurement and analytical interference were studied between the two test systems. RESULTS: The performance of SCr from the open test system was in compliance with the matched test system with good precision, accuracy, and linearity. In presence of most common interferents, both test systems could lead to accurate creatinine results except for the existence of specified drugs. For dobutamine, the open test system showed better anti‐interference performance than the matched system. CONCLUSION: This study provides referable opinions for clinical laboratory selection on the test system and a framework for future analogous studies based on different test systems. John Wiley and Sons Inc. 2021-12-26 /pmc/articles/PMC8842161/ /pubmed/34957600 http://dx.doi.org/10.1002/jcla.24206 Text en © 2021 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles He, Lina Yu, Jinqi Han, Guang Huang, Di Han, Liqiao Zhang, Qiaoxuan Wang, Yunxiu Wan, Zemin Huang, Xian‐Zhang Xiong, Yujuan Wu, Xiaobin Analytical performance evaluation of different test systems on serum creatinine assay |
title | Analytical performance evaluation of different test systems on serum creatinine assay |
title_full | Analytical performance evaluation of different test systems on serum creatinine assay |
title_fullStr | Analytical performance evaluation of different test systems on serum creatinine assay |
title_full_unstemmed | Analytical performance evaluation of different test systems on serum creatinine assay |
title_short | Analytical performance evaluation of different test systems on serum creatinine assay |
title_sort | analytical performance evaluation of different test systems on serum creatinine assay |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8842161/ https://www.ncbi.nlm.nih.gov/pubmed/34957600 http://dx.doi.org/10.1002/jcla.24206 |
work_keys_str_mv | AT helina analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT yujinqi analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT hanguang analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT huangdi analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT hanliqiao analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT zhangqiaoxuan analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT wangyunxiu analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT wanzemin analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT huangxianzhang analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT xiongyujuan analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay AT wuxiaobin analyticalperformanceevaluationofdifferenttestsystemsonserumcreatinineassay |