Cargando…
Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments
OBJECTIVE: The aim of this study was to evaluate the bending and torsional resistance of the following instruments: Mtwo 25/.07 (MT - VDW, Munich, Germany), Navigator W-XN 25.07 (WXN - Wizard Navigator, Medin, Nové Město na Moravě, Czech Republic), ProTaper Universal SX 19/.04 (PSX - Dentsply Tulsa...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Carol Davila University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8842434/ https://www.ncbi.nlm.nih.gov/pubmed/34967334 http://dx.doi.org/10.14744/eej.2021.25238 |
_version_ | 1784651049035890688 |
---|---|
author | WEISSHEIMER, Theodoro ALCALDE, Murilo Priori CORTEZ, Julia Barrionuevo da ROSA, Ricardo Abreu VIVAN, Rodrigo Ricci CALEFI, Pedro Henrique Souza DUARTE, Marco Antonio Hungaro SÓ, Marcus Vinicius Reis |
author_facet | WEISSHEIMER, Theodoro ALCALDE, Murilo Priori CORTEZ, Julia Barrionuevo da ROSA, Ricardo Abreu VIVAN, Rodrigo Ricci CALEFI, Pedro Henrique Souza DUARTE, Marco Antonio Hungaro SÓ, Marcus Vinicius Reis |
author_sort | WEISSHEIMER, Theodoro |
collection | PubMed |
description | OBJECTIVE: The aim of this study was to evaluate the bending and torsional resistance of the following instruments: Mtwo 25/.07 (MT - VDW, Munich, Germany), Navigator W-XN 25.07 (WXN - Wizard Navigator, Medin, Nové Město na Moravě, Czech Republic), ProTaper Universal SX 19/.04 (PSX - Dentsply Tulsa Dental Specialties, Tulsa, USA), MK Orifice Shapper 17/.08 (OS - MK Life Medical and Dental Products, Porto Alegre, Brazil) and MK Sequence 17.12 (MKS - MK Life Medical and Dental Products, Porto Alegre, Brazil). METHODS: One hundred instruments were used (n=20). Resistance to bending (n=10), torque and angular deflection (n=10) at the failure of new instruments were measured according to ISO 3630-1. Metal mass volume at 3 mm from the tip was evaluated using micro-computed tomography (micro-CT). The fractured surface of each fragment was examined by scanning electron microscopy (SEM). Data were analysed using 1-way analysis of variance and Tukey tests. RESULTS: Torsional resistance values of MK Sequence were higher than the other groups (P<0.05). No differences were observed among MT, WXN and OS (P>0.05) and PTS, which presented the lowest values (P<0.05). MT showed the highest angular deflection (P<0.05). WXN and PSX presented no significant difference (P>0.05). PSX and OS also showed no significant differences (P>0.05). MKS instruments had the lowest angular deflection values (P<0.05). There were significant differences among all the groups in bending stiffness test (P<0.05), but PSX had the lowest torque to bend (P<0.05). MKS had the larger metal mass volume at 3 mm from the tip (P<0.05). SEM analysis showed similar and typical features of torsional failure for all instruments tested. CONCLUSION: In conclusion, MK Sequence 17/.12 had the highest torsional fracture resistance. Mtwo 25/.07 showed higher angular deflection capacity, and ProTaper Universal SX the 19/.04 lower bending stiffness. |
format | Online Article Text |
id | pubmed-8842434 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Carol Davila University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-88424342022-02-28 Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments WEISSHEIMER, Theodoro ALCALDE, Murilo Priori CORTEZ, Julia Barrionuevo da ROSA, Ricardo Abreu VIVAN, Rodrigo Ricci CALEFI, Pedro Henrique Souza DUARTE, Marco Antonio Hungaro SÓ, Marcus Vinicius Reis Eur Endod J Original Article OBJECTIVE: The aim of this study was to evaluate the bending and torsional resistance of the following instruments: Mtwo 25/.07 (MT - VDW, Munich, Germany), Navigator W-XN 25.07 (WXN - Wizard Navigator, Medin, Nové Město na Moravě, Czech Republic), ProTaper Universal SX 19/.04 (PSX - Dentsply Tulsa Dental Specialties, Tulsa, USA), MK Orifice Shapper 17/.08 (OS - MK Life Medical and Dental Products, Porto Alegre, Brazil) and MK Sequence 17.12 (MKS - MK Life Medical and Dental Products, Porto Alegre, Brazil). METHODS: One hundred instruments were used (n=20). Resistance to bending (n=10), torque and angular deflection (n=10) at the failure of new instruments were measured according to ISO 3630-1. Metal mass volume at 3 mm from the tip was evaluated using micro-computed tomography (micro-CT). The fractured surface of each fragment was examined by scanning electron microscopy (SEM). Data were analysed using 1-way analysis of variance and Tukey tests. RESULTS: Torsional resistance values of MK Sequence were higher than the other groups (P<0.05). No differences were observed among MT, WXN and OS (P>0.05) and PTS, which presented the lowest values (P<0.05). MT showed the highest angular deflection (P<0.05). WXN and PSX presented no significant difference (P>0.05). PSX and OS also showed no significant differences (P>0.05). MKS instruments had the lowest angular deflection values (P<0.05). There were significant differences among all the groups in bending stiffness test (P<0.05), but PSX had the lowest torque to bend (P<0.05). MKS had the larger metal mass volume at 3 mm from the tip (P<0.05). SEM analysis showed similar and typical features of torsional failure for all instruments tested. CONCLUSION: In conclusion, MK Sequence 17/.12 had the highest torsional fracture resistance. Mtwo 25/.07 showed higher angular deflection capacity, and ProTaper Universal SX the 19/.04 lower bending stiffness. Carol Davila University Press 2021-11-18 /pmc/articles/PMC8842434/ /pubmed/34967334 http://dx.doi.org/10.14744/eej.2021.25238 Text en ©2021 European Endodontic Journal https://creativecommons.org/licenses/by/3.0/This article is distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ), which permits unrestricted use and redistribution provided that the original author and source are credited. |
spellingShingle | Original Article WEISSHEIMER, Theodoro ALCALDE, Murilo Priori CORTEZ, Julia Barrionuevo da ROSA, Ricardo Abreu VIVAN, Rodrigo Ricci CALEFI, Pedro Henrique Souza DUARTE, Marco Antonio Hungaro SÓ, Marcus Vinicius Reis Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments |
title | Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments |
title_full | Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments |
title_fullStr | Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments |
title_full_unstemmed | Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments |
title_short | Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments |
title_sort | evaluation of torsional resistance and bending stiffness of coronal flaring nickel-titanium instruments |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8842434/ https://www.ncbi.nlm.nih.gov/pubmed/34967334 http://dx.doi.org/10.14744/eej.2021.25238 |
work_keys_str_mv | AT weissheimertheodoro evaluationoftorsionalresistanceandbendingstiffnessofcoronalflaringnickeltitaniuminstruments AT alcaldemurilopriori evaluationoftorsionalresistanceandbendingstiffnessofcoronalflaringnickeltitaniuminstruments AT cortezjuliabarrionuevo evaluationoftorsionalresistanceandbendingstiffnessofcoronalflaringnickeltitaniuminstruments AT darosaricardoabreu evaluationoftorsionalresistanceandbendingstiffnessofcoronalflaringnickeltitaniuminstruments AT vivanrodrigoricci evaluationoftorsionalresistanceandbendingstiffnessofcoronalflaringnickeltitaniuminstruments AT calefipedrohenriquesouza evaluationoftorsionalresistanceandbendingstiffnessofcoronalflaringnickeltitaniuminstruments AT duartemarcoantoniohungaro evaluationoftorsionalresistanceandbendingstiffnessofcoronalflaringnickeltitaniuminstruments AT somarcusviniciusreis evaluationoftorsionalresistanceandbendingstiffnessofcoronalflaringnickeltitaniuminstruments |