Cargando…
Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein
SARS-CoV-2 nucleocapsid protein-based COVID-19 diagnosis is a promising alternative to the high-priced, time-consuming, and labor-intensive RT-PCR tests. Here, we developed a rapid, dip-type, wash-free plasmonic fiber optic absorbance biosensor (P-FAB) strategy for the point-of-care detection of SAR...
Formato: | Online Artículo Texto |
---|---|
Lenguaje: | English |
Publicado: |
IEEE
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843044/ https://www.ncbi.nlm.nih.gov/pubmed/35582121 http://dx.doi.org/10.1109/JSEN.2021.3107736 |
_version_ | 1784651169292877824 |
---|---|
collection | PubMed |
description | SARS-CoV-2 nucleocapsid protein-based COVID-19 diagnosis is a promising alternative to the high-priced, time-consuming, and labor-intensive RT-PCR tests. Here, we developed a rapid, dip-type, wash-free plasmonic fiber optic absorbance biosensor (P-FAB) strategy for the point-of-care detection of SARS-CoV-2 N-protein, expressed abundantly during the infection. P-FAB involves a sandwich assay with plasmonic labels on the surface of a U-bent fiber optic sensor probe with a high evanescent wave absorbance (EWA) sensitivity. The SARS-CoV-2 N-protein is quantified in terms of the change in the intensity of the light propagating through the U-bent sensor probe coupled to a green LED and a photodetector. Firstly, the optical fiber material (silica vs. polymeric optical fiber), was evaluated to realize a sensitive sensor platform. The optimal size of AuNP labels (20, 40, and 60 nm) to achieve high sensitivity and a lower limit of detection (LoD) was investigated. Following the P-FAB strategy, fused silica/glass optical fiber (GOF) U-bent senor probe and citrate-capped AuNP labels (size ~40 nm) gave rise to an LoD down to ~2.5 ng/mL within 10 mins of read-out time. Further, studies on development and validation of a point of care (PoC) read-out device, and preclinical studies are in progress. |
format | Online Article Text |
id | pubmed-8843044 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | IEEE |
record_format | MEDLINE/PubMed |
spelling | pubmed-88430442022-05-13 Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein IEEE Sens J Article SARS-CoV-2 nucleocapsid protein-based COVID-19 diagnosis is a promising alternative to the high-priced, time-consuming, and labor-intensive RT-PCR tests. Here, we developed a rapid, dip-type, wash-free plasmonic fiber optic absorbance biosensor (P-FAB) strategy for the point-of-care detection of SARS-CoV-2 N-protein, expressed abundantly during the infection. P-FAB involves a sandwich assay with plasmonic labels on the surface of a U-bent fiber optic sensor probe with a high evanescent wave absorbance (EWA) sensitivity. The SARS-CoV-2 N-protein is quantified in terms of the change in the intensity of the light propagating through the U-bent sensor probe coupled to a green LED and a photodetector. Firstly, the optical fiber material (silica vs. polymeric optical fiber), was evaluated to realize a sensitive sensor platform. The optimal size of AuNP labels (20, 40, and 60 nm) to achieve high sensitivity and a lower limit of detection (LoD) was investigated. Following the P-FAB strategy, fused silica/glass optical fiber (GOF) U-bent senor probe and citrate-capped AuNP labels (size ~40 nm) gave rise to an LoD down to ~2.5 ng/mL within 10 mins of read-out time. Further, studies on development and validation of a point of care (PoC) read-out device, and preclinical studies are in progress. IEEE 2021-08-24 /pmc/articles/PMC8843044/ /pubmed/35582121 http://dx.doi.org/10.1109/JSEN.2021.3107736 Text en This article is free to access and download, along with rights for full text and data mining, re-use and analysis. |
spellingShingle | Article Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein |
title | Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein |
title_full | Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein |
title_fullStr | Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein |
title_full_unstemmed | Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein |
title_short | Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein |
title_sort | plasmonic fiberoptic absorbance biosensor (p-fab) for rapid detection of sars-cov-2 nucleocapsid protein |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843044/ https://www.ncbi.nlm.nih.gov/pubmed/35582121 http://dx.doi.org/10.1109/JSEN.2021.3107736 |
work_keys_str_mv | AT plasmonicfiberopticabsorbancebiosensorpfabforrapiddetectionofsarscov2nucleocapsidprotein AT plasmonicfiberopticabsorbancebiosensorpfabforrapiddetectionofsarscov2nucleocapsidprotein AT plasmonicfiberopticabsorbancebiosensorpfabforrapiddetectionofsarscov2nucleocapsidprotein AT plasmonicfiberopticabsorbancebiosensorpfabforrapiddetectionofsarscov2nucleocapsidprotein AT plasmonicfiberopticabsorbancebiosensorpfabforrapiddetectionofsarscov2nucleocapsidprotein AT plasmonicfiberopticabsorbancebiosensorpfabforrapiddetectionofsarscov2nucleocapsidprotein AT plasmonicfiberopticabsorbancebiosensorpfabforrapiddetectionofsarscov2nucleocapsidprotein |