Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice
SIGNIFICANCE: Intrinsic optical signals (IOS) generated in the cortical tissue as a result of various interacting metabolic processes are used extensively to elucidate the underlying mechanisms that govern neurovascular coupling. However, current IOS measurements still often rely on bulky, tabletop...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843356/ https://www.ncbi.nlm.nih.gov/pubmed/35166087 http://dx.doi.org/10.1117/1.JBO.27.2.026501 |
_version_ | 1784651238749503488 |
---|---|
author | Guinto, Mark Christian Haruta, Makito Kurauchi, Yuki Saigo, Taisuke Kurasawa, Kazuki Ryu, Sumika Ohta, Yasumi Kawahara, Mamiko Takehara, Hironari Tashiro, Hiroyuki Sasagawa, Kiyotaka Katsuki, Hiroshi Ohta, Jun |
author_facet | Guinto, Mark Christian Haruta, Makito Kurauchi, Yuki Saigo, Taisuke Kurasawa, Kazuki Ryu, Sumika Ohta, Yasumi Kawahara, Mamiko Takehara, Hironari Tashiro, Hiroyuki Sasagawa, Kiyotaka Katsuki, Hiroshi Ohta, Jun |
author_sort | Guinto, Mark Christian |
collection | PubMed |
description | SIGNIFICANCE: Intrinsic optical signals (IOS) generated in the cortical tissue as a result of various interacting metabolic processes are used extensively to elucidate the underlying mechanisms that govern neurovascular coupling. However, current IOS measurements still often rely on bulky, tabletop imaging systems, and there remains a dearth of studies in freely moving subjects. Lightweight, miniature head-mounted imaging devices provide unique opportunities for investigating cortical dynamics in small animals under a variety of naturalistic behavioral settings. AIM: The aim of this work was to monitor IOS in the somatosensory cortex of wild-type mice by developing a lightweight, biocompatible imaging device that readily lends itself to animal experiments in freely moving conditions. APPROACH: Herein we describe a method for realizing long-term IOS imaging in mice using a 0.54-g, compact, CMOS-based, head-mounted imager. The two-part module, consisting of a tethered sensor plate and a base plate, allows facile assembly prior to imaging sessions and disassembly when the sensor is not in use. LEDs integrated into the device were chosen to illuminate the cortical mantle at two different wavelengths in the visible regime ([Formula: see text]: 535 and 625 nm) for monitoring volume- and oxygenation state-dependent changes in the IOS, respectively. To test whether the system can detect robust cortical responses, we recorded sensory-evoked IOS from mechanical stimulation of the hindlimbs (HL) of anesthetized mice in both acute and long-term implantation conditions. RESULTS: Cortical IOS recordings in the primary somatosensory cortex hindlimb receptive field (S1HL) of anesthetized mice under green and red LED illumination revealed robust, multiphasic profiles that were time-locked to the mechanical stimulation of the contralateral plantar hindpaw. Similar intrinsic signal profiles observed in S1HL at 40 days postimplantation demonstrated the viability of the approach for long-term imaging. Immunohistochemical analysis showed that the brain tissue did not exhibit appreciable immune response due to the device implantation and operation. A proof-of-principle imaging session in a freely behaving mouse showed minimal locomotor impediment for the animal and also enabled estimation of blood flow speed. CONCLUSIONS: We demonstrate the utility of a miniature cortical imaging device for monitoring IOS and related hemodynamic processes in both anesthetized and freely moving mice, cueing potential for applications to some neuroscientific studies of sensation and naturalistic behavior. |
format | Online Article Text |
id | pubmed-8843356 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-88433562022-02-16 Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice Guinto, Mark Christian Haruta, Makito Kurauchi, Yuki Saigo, Taisuke Kurasawa, Kazuki Ryu, Sumika Ohta, Yasumi Kawahara, Mamiko Takehara, Hironari Tashiro, Hiroyuki Sasagawa, Kiyotaka Katsuki, Hiroshi Ohta, Jun J Biomed Opt Microscopy SIGNIFICANCE: Intrinsic optical signals (IOS) generated in the cortical tissue as a result of various interacting metabolic processes are used extensively to elucidate the underlying mechanisms that govern neurovascular coupling. However, current IOS measurements still often rely on bulky, tabletop imaging systems, and there remains a dearth of studies in freely moving subjects. Lightweight, miniature head-mounted imaging devices provide unique opportunities for investigating cortical dynamics in small animals under a variety of naturalistic behavioral settings. AIM: The aim of this work was to monitor IOS in the somatosensory cortex of wild-type mice by developing a lightweight, biocompatible imaging device that readily lends itself to animal experiments in freely moving conditions. APPROACH: Herein we describe a method for realizing long-term IOS imaging in mice using a 0.54-g, compact, CMOS-based, head-mounted imager. The two-part module, consisting of a tethered sensor plate and a base plate, allows facile assembly prior to imaging sessions and disassembly when the sensor is not in use. LEDs integrated into the device were chosen to illuminate the cortical mantle at two different wavelengths in the visible regime ([Formula: see text]: 535 and 625 nm) for monitoring volume- and oxygenation state-dependent changes in the IOS, respectively. To test whether the system can detect robust cortical responses, we recorded sensory-evoked IOS from mechanical stimulation of the hindlimbs (HL) of anesthetized mice in both acute and long-term implantation conditions. RESULTS: Cortical IOS recordings in the primary somatosensory cortex hindlimb receptive field (S1HL) of anesthetized mice under green and red LED illumination revealed robust, multiphasic profiles that were time-locked to the mechanical stimulation of the contralateral plantar hindpaw. Similar intrinsic signal profiles observed in S1HL at 40 days postimplantation demonstrated the viability of the approach for long-term imaging. Immunohistochemical analysis showed that the brain tissue did not exhibit appreciable immune response due to the device implantation and operation. A proof-of-principle imaging session in a freely behaving mouse showed minimal locomotor impediment for the animal and also enabled estimation of blood flow speed. CONCLUSIONS: We demonstrate the utility of a miniature cortical imaging device for monitoring IOS and related hemodynamic processes in both anesthetized and freely moving mice, cueing potential for applications to some neuroscientific studies of sensation and naturalistic behavior. Society of Photo-Optical Instrumentation Engineers 2022-02-14 2022-02 /pmc/articles/PMC8843356/ /pubmed/35166087 http://dx.doi.org/10.1117/1.JBO.27.2.026501 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Microscopy Guinto, Mark Christian Haruta, Makito Kurauchi, Yuki Saigo, Taisuke Kurasawa, Kazuki Ryu, Sumika Ohta, Yasumi Kawahara, Mamiko Takehara, Hironari Tashiro, Hiroyuki Sasagawa, Kiyotaka Katsuki, Hiroshi Ohta, Jun Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice |
title | Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice |
title_full | Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice |
title_fullStr | Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice |
title_full_unstemmed | Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice |
title_short | Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice |
title_sort | modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice |
topic | Microscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843356/ https://www.ncbi.nlm.nih.gov/pubmed/35166087 http://dx.doi.org/10.1117/1.JBO.27.2.026501 |
work_keys_str_mv | AT guintomarkchristian modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT harutamakito modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT kurauchiyuki modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT saigotaisuke modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT kurasawakazuki modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT ryusumika modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT ohtayasumi modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT kawaharamamiko modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT takeharahironari modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT tashirohiroyuki modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT sasagawakiyotaka modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT katsukihiroshi modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice AT ohtajun modularheadmountedcorticalimagingdeviceforchronicmonitoringofintrinsicsignalsinmice |