Cargando…
Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure
INTRODUCTION: Bernese periacetabular osteotomy is an effective procedure for treating acetabular dysplasia. However, limited visual control of the acetabular position during surgery may result in under- or overcorrection with residual dysplasia or femoroacetabular impingement. Thus, we wanted to fin...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843857/ https://www.ncbi.nlm.nih.gov/pubmed/33098458 http://dx.doi.org/10.1007/s00402-020-03632-y |
_version_ | 1784651356068380672 |
---|---|
author | Schwarz, Timo J. Maderbacher, Günther Leiss, Franziska Grifka, Joachim Heers, G. Matussek, J. |
author_facet | Schwarz, Timo J. Maderbacher, Günther Leiss, Franziska Grifka, Joachim Heers, G. Matussek, J. |
author_sort | Schwarz, Timo J. |
collection | PubMed |
description | INTRODUCTION: Bernese periacetabular osteotomy is an effective procedure for treating acetabular dysplasia. However, limited visual control of the acetabular position during surgery may result in under- or overcorrection with residual dysplasia or femoroacetabular impingement. Thus, we wanted to find a simple method to control the effect of correction in the sagittal and coronal plane. METHOD: The acetabular coordinates are shown by two perpendicular tubes of an external fixator mounted onto a third tube that is fixed to the acetabular fragment with two Schanz screws. This method enables the isolated acetabular reorientation in the coronal, sagittal, and transverse plane. In a sawbone pelvis model, the acetabular rim is marked with a copper wire and a silicon adherent. To show the radiographic effect on acetabular parameters and the rim position, we visualized correction in the coronal and sagittal plane under fluoroscopic control. RESULTS: Lateral rotation of the acetabular fragment had the highest impact on radiographic lateral coverage of the femoral head. But also ventral coverage increased during isolated lateral rotation. Anterior rotation showed almost no effect on lateral coverage and just a little effect on ventral coverage but caused severe total acetabular retroversion. CONCLUSION: Three-dimensional control of the acetabular orientation during periacetabular osteotomy is important to avoid over- and under-correction. Isolated lateral rotation of the acetabular fragment should be the predominant direction of correction during periacetabular osteotomy. Ambitious anterior correction may be the main source for severe acetabular retroversion following periacetabular osteotomy. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00402-020-03632-y) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-8843857 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-88438572022-02-23 Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure Schwarz, Timo J. Maderbacher, Günther Leiss, Franziska Grifka, Joachim Heers, G. Matussek, J. Arch Orthop Trauma Surg Orthopaedic Surgery INTRODUCTION: Bernese periacetabular osteotomy is an effective procedure for treating acetabular dysplasia. However, limited visual control of the acetabular position during surgery may result in under- or overcorrection with residual dysplasia or femoroacetabular impingement. Thus, we wanted to find a simple method to control the effect of correction in the sagittal and coronal plane. METHOD: The acetabular coordinates are shown by two perpendicular tubes of an external fixator mounted onto a third tube that is fixed to the acetabular fragment with two Schanz screws. This method enables the isolated acetabular reorientation in the coronal, sagittal, and transverse plane. In a sawbone pelvis model, the acetabular rim is marked with a copper wire and a silicon adherent. To show the radiographic effect on acetabular parameters and the rim position, we visualized correction in the coronal and sagittal plane under fluoroscopic control. RESULTS: Lateral rotation of the acetabular fragment had the highest impact on radiographic lateral coverage of the femoral head. But also ventral coverage increased during isolated lateral rotation. Anterior rotation showed almost no effect on lateral coverage and just a little effect on ventral coverage but caused severe total acetabular retroversion. CONCLUSION: Three-dimensional control of the acetabular orientation during periacetabular osteotomy is important to avoid over- and under-correction. Isolated lateral rotation of the acetabular fragment should be the predominant direction of correction during periacetabular osteotomy. Ambitious anterior correction may be the main source for severe acetabular retroversion following periacetabular osteotomy. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00402-020-03632-y) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2020-10-24 2022 /pmc/articles/PMC8843857/ /pubmed/33098458 http://dx.doi.org/10.1007/s00402-020-03632-y Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Orthopaedic Surgery Schwarz, Timo J. Maderbacher, Günther Leiss, Franziska Grifka, Joachim Heers, G. Matussek, J. Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure |
title | Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure |
title_full | Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure |
title_fullStr | Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure |
title_full_unstemmed | Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure |
title_short | Three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure |
title_sort | three-dimensional acetabular orientation during periacetabular osteotomy: a video analysis of acetabular rim position using an external fixator as navigation tool during reorientation procedure |
topic | Orthopaedic Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843857/ https://www.ncbi.nlm.nih.gov/pubmed/33098458 http://dx.doi.org/10.1007/s00402-020-03632-y |
work_keys_str_mv | AT schwarztimoj threedimensionalacetabularorientationduringperiacetabularosteotomyavideoanalysisofacetabularrimpositionusinganexternalfixatorasnavigationtoolduringreorientationprocedure AT maderbachergunther threedimensionalacetabularorientationduringperiacetabularosteotomyavideoanalysisofacetabularrimpositionusinganexternalfixatorasnavigationtoolduringreorientationprocedure AT leissfranziska threedimensionalacetabularorientationduringperiacetabularosteotomyavideoanalysisofacetabularrimpositionusinganexternalfixatorasnavigationtoolduringreorientationprocedure AT grifkajoachim threedimensionalacetabularorientationduringperiacetabularosteotomyavideoanalysisofacetabularrimpositionusinganexternalfixatorasnavigationtoolduringreorientationprocedure AT heersg threedimensionalacetabularorientationduringperiacetabularosteotomyavideoanalysisofacetabularrimpositionusinganexternalfixatorasnavigationtoolduringreorientationprocedure AT matussekj threedimensionalacetabularorientationduringperiacetabularosteotomyavideoanalysisofacetabularrimpositionusinganexternalfixatorasnavigationtoolduringreorientationprocedure |