Cargando…

Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT

Iodine contrast agent is widely used in liver cancer radiotherapy at CT simulation stage to enhance detectability of tumor. However, its application in cone beam CT (CBCT) for image guidance before treatment delivery is still limited because of poor image quality and excessive dose of contrast agent...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Chao, Jung, Hyunuk, Yang, Ming, Shen, Chenyang, Jia, Xun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843938/
https://www.ncbi.nlm.nih.gov/pubmed/35178351
http://dx.doi.org/10.3389/fonc.2022.827136
_version_ 1784651374290534400
author Wang, Chao
Jung, Hyunuk
Yang, Ming
Shen, Chenyang
Jia, Xun
author_facet Wang, Chao
Jung, Hyunuk
Yang, Ming
Shen, Chenyang
Jia, Xun
author_sort Wang, Chao
collection PubMed
description Iodine contrast agent is widely used in liver cancer radiotherapy at CT simulation stage to enhance detectability of tumor. However, its application in cone beam CT (CBCT) for image guidance before treatment delivery is still limited because of poor image quality and excessive dose of contrast agent during multiple treatment fractions. We previously developed a multienergy element-resolved (MEER) CBCT framework that included x-ray projection data acquisition on a conventional CBCT platform in a kVp-switching model and a dictionary-based image reconstruction algorithm that simultaneously reconstructed x-ray attenuation images at each kilovoltage peak (kVp), an electron density image, and elemental composition images. In this study, we investigated feasibility using MEER-CBCT for low-concentration iodine contrast agent visualization. We performed simulation and experimental studies using a phantom with inserts containing water and different concentrations of iodine solution and the MEER-CBCT scan with 600 projections in a full gantry rotation, in which the kVp level sequentially changed among 80, 100, and 120 kVps. We included iodine material in the dictionary of the reconstruction algorithm. We analyzed iodine detectability as quantified by contrast-to-noise ratio (CNR) and compared results with those of CBCT images reconstructed by the standard filter back projection (FBP) method with 600 projections. MEER-CBCT achieved similar contrast enhancement as FBP method but significantly higher CNR. At 2.5% iodine solution concentration, FBP method achieved 170 HU enhancement and CNR of 2.0, considered the standard CNR for successful tumor visualization. MEER-CBCT achieved the same CNR but at ~6.3 times lower iodine concentration of 0.4%.
format Online
Article
Text
id pubmed-8843938
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-88439382022-02-16 Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT Wang, Chao Jung, Hyunuk Yang, Ming Shen, Chenyang Jia, Xun Front Oncol Oncology Iodine contrast agent is widely used in liver cancer radiotherapy at CT simulation stage to enhance detectability of tumor. However, its application in cone beam CT (CBCT) for image guidance before treatment delivery is still limited because of poor image quality and excessive dose of contrast agent during multiple treatment fractions. We previously developed a multienergy element-resolved (MEER) CBCT framework that included x-ray projection data acquisition on a conventional CBCT platform in a kVp-switching model and a dictionary-based image reconstruction algorithm that simultaneously reconstructed x-ray attenuation images at each kilovoltage peak (kVp), an electron density image, and elemental composition images. In this study, we investigated feasibility using MEER-CBCT for low-concentration iodine contrast agent visualization. We performed simulation and experimental studies using a phantom with inserts containing water and different concentrations of iodine solution and the MEER-CBCT scan with 600 projections in a full gantry rotation, in which the kVp level sequentially changed among 80, 100, and 120 kVps. We included iodine material in the dictionary of the reconstruction algorithm. We analyzed iodine detectability as quantified by contrast-to-noise ratio (CNR) and compared results with those of CBCT images reconstructed by the standard filter back projection (FBP) method with 600 projections. MEER-CBCT achieved similar contrast enhancement as FBP method but significantly higher CNR. At 2.5% iodine solution concentration, FBP method achieved 170 HU enhancement and CNR of 2.0, considered the standard CNR for successful tumor visualization. MEER-CBCT achieved the same CNR but at ~6.3 times lower iodine concentration of 0.4%. Frontiers Media S.A. 2022-02-01 /pmc/articles/PMC8843938/ /pubmed/35178351 http://dx.doi.org/10.3389/fonc.2022.827136 Text en Copyright © 2022 Wang, Jung, Yang, Shen and Jia https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Wang, Chao
Jung, Hyunuk
Yang, Ming
Shen, Chenyang
Jia, Xun
Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT
title Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT
title_full Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT
title_fullStr Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT
title_full_unstemmed Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT
title_short Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT
title_sort simultaneous image reconstruction and element decomposition for iodine contrast agent visualization in multienergy element-resolved cone beam ct
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843938/
https://www.ncbi.nlm.nih.gov/pubmed/35178351
http://dx.doi.org/10.3389/fonc.2022.827136
work_keys_str_mv AT wangchao simultaneousimagereconstructionandelementdecompositionforiodinecontrastagentvisualizationinmultienergyelementresolvedconebeamct
AT junghyunuk simultaneousimagereconstructionandelementdecompositionforiodinecontrastagentvisualizationinmultienergyelementresolvedconebeamct
AT yangming simultaneousimagereconstructionandelementdecompositionforiodinecontrastagentvisualizationinmultienergyelementresolvedconebeamct
AT shenchenyang simultaneousimagereconstructionandelementdecompositionforiodinecontrastagentvisualizationinmultienergyelementresolvedconebeamct
AT jiaxun simultaneousimagereconstructionandelementdecompositionforiodinecontrastagentvisualizationinmultienergyelementresolvedconebeamct