Cargando…

A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR

The global public health crisis and economic losses resulting from the current novel coronavirus disease (COVID-19) pandemic have been dire. The most used real-time reverse transcription polymerase chain reaction (RT-PCR) method needs expensive equipment, technical expertise, and a long turnaround t...

Descripción completa

Detalles Bibliográficos
Autores principales: Odiwuor, Nelson, Xiong, Jin, Ogolla, Faith, Hong, Wei, Li, Xiaohong, Khan, Fazal Mehmood, Wang, Nuo, Yu, Junping, Wei, Hongping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8844505/
https://www.ncbi.nlm.nih.gov/pubmed/35256137
http://dx.doi.org/10.1016/j.aca.2022.339590
_version_ 1784651491933421568
author Odiwuor, Nelson
Xiong, Jin
Ogolla, Faith
Hong, Wei
Li, Xiaohong
Khan, Fazal Mehmood
Wang, Nuo
Yu, Junping
Wei, Hongping
author_facet Odiwuor, Nelson
Xiong, Jin
Ogolla, Faith
Hong, Wei
Li, Xiaohong
Khan, Fazal Mehmood
Wang, Nuo
Yu, Junping
Wei, Hongping
author_sort Odiwuor, Nelson
collection PubMed
description The global public health crisis and economic losses resulting from the current novel coronavirus disease (COVID-19) pandemic have been dire. The most used real-time reverse transcription polymerase chain reaction (RT-PCR) method needs expensive equipment, technical expertise, and a long turnaround time. Therefore, there is a need for a rapid, accurate, and alternative technique of diagnosis that is deployable at resource-poor settings like point-of-care. This study combines heat deactivation and a novel mechanical lysis method by bead beating for quick and simple sample preparation. Then, using an optimized reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay to target genes encoding the open reading frame 8 (ORF8), spike and nucleocapsid proteins of the novel coronavirus, SARS-CoV-2. The test results can be read simultaneously in fluorometric and colorimetric readouts within 40 min from sample collection. We also calibrated a template transfer tool to simplify sample addition into LAMP reactions when pipetting skills are needed. Most importantly, validation of the direct RT-LAMP system based on multiplexing primers S1:ORF8 in a ratio (1:0.8) using 143 patients’ nasopharyngeal swab samples showed a diagnostic performance of 99.30% accuracy, with 98.81% sensitivity and 100% selectivity, compared to commercial RT-PCR kits. Since our workflow does not rely on RNA extraction and purification, the time-to-result is two times faster than other workflows with FDA emergency use authorization. Considering all its strengths: speed, simplicity, accuracy and extraction-free, the system can be useful for optimal point-of-care testing of COVID-19.
format Online
Article
Text
id pubmed-8844505
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-88445052022-02-15 A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR Odiwuor, Nelson Xiong, Jin Ogolla, Faith Hong, Wei Li, Xiaohong Khan, Fazal Mehmood Wang, Nuo Yu, Junping Wei, Hongping Anal Chim Acta Article The global public health crisis and economic losses resulting from the current novel coronavirus disease (COVID-19) pandemic have been dire. The most used real-time reverse transcription polymerase chain reaction (RT-PCR) method needs expensive equipment, technical expertise, and a long turnaround time. Therefore, there is a need for a rapid, accurate, and alternative technique of diagnosis that is deployable at resource-poor settings like point-of-care. This study combines heat deactivation and a novel mechanical lysis method by bead beating for quick and simple sample preparation. Then, using an optimized reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay to target genes encoding the open reading frame 8 (ORF8), spike and nucleocapsid proteins of the novel coronavirus, SARS-CoV-2. The test results can be read simultaneously in fluorometric and colorimetric readouts within 40 min from sample collection. We also calibrated a template transfer tool to simplify sample addition into LAMP reactions when pipetting skills are needed. Most importantly, validation of the direct RT-LAMP system based on multiplexing primers S1:ORF8 in a ratio (1:0.8) using 143 patients’ nasopharyngeal swab samples showed a diagnostic performance of 99.30% accuracy, with 98.81% sensitivity and 100% selectivity, compared to commercial RT-PCR kits. Since our workflow does not rely on RNA extraction and purification, the time-to-result is two times faster than other workflows with FDA emergency use authorization. Considering all its strengths: speed, simplicity, accuracy and extraction-free, the system can be useful for optimal point-of-care testing of COVID-19. Elsevier B.V. 2022-04-01 2022-02-15 /pmc/articles/PMC8844505/ /pubmed/35256137 http://dx.doi.org/10.1016/j.aca.2022.339590 Text en © 2022 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Odiwuor, Nelson
Xiong, Jin
Ogolla, Faith
Hong, Wei
Li, Xiaohong
Khan, Fazal Mehmood
Wang, Nuo
Yu, Junping
Wei, Hongping
A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR
title A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR
title_full A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR
title_fullStr A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR
title_full_unstemmed A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR
title_short A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR
title_sort point-of-care sars-cov-2 test based on reverse transcription loop-mediated isothermal amplification without rna extraction with diagnostic performance same as rt-pcr
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8844505/
https://www.ncbi.nlm.nih.gov/pubmed/35256137
http://dx.doi.org/10.1016/j.aca.2022.339590
work_keys_str_mv AT odiwuornelson apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT xiongjin apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT ogollafaith apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT hongwei apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT lixiaohong apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT khanfazalmehmood apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT wangnuo apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT yujunping apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT weihongping apointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT odiwuornelson pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT xiongjin pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT ogollafaith pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT hongwei pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT lixiaohong pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT khanfazalmehmood pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT wangnuo pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT yujunping pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr
AT weihongping pointofcaresarscov2testbasedonreversetranscriptionloopmediatedisothermalamplificationwithoutrnaextractionwithdiagnosticperformancesameasrtpcr