Cargando…
Proton range monitoring using (13)N peak for proton therapy applications
The Monte Carlo method is employed in this study to simulate the proton irradiation of a water-gel phantom. Positron-emitting radionuclides such as (11)C, (15)O, and (13)N are scored using the Particle and Heavy Ion Transport Code System Monte Carlo code package. Previously, it was reported that as...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8846528/ https://www.ncbi.nlm.nih.gov/pubmed/35167589 http://dx.doi.org/10.1371/journal.pone.0263521 |
_version_ | 1784651863787831296 |
---|---|
author | Islam, M. Rafiqul Shahmohammadi Beni, Mehrdad Ng, Chor-yi Miyake, Masayasu Rahman, Mahabubur Ito, Shigeki Gotoh, Shinichi Yamaya, Taiga Watabe, Hiroshi |
author_facet | Islam, M. Rafiqul Shahmohammadi Beni, Mehrdad Ng, Chor-yi Miyake, Masayasu Rahman, Mahabubur Ito, Shigeki Gotoh, Shinichi Yamaya, Taiga Watabe, Hiroshi |
author_sort | Islam, M. Rafiqul |
collection | PubMed |
description | The Monte Carlo method is employed in this study to simulate the proton irradiation of a water-gel phantom. Positron-emitting radionuclides such as (11)C, (15)O, and (13)N are scored using the Particle and Heavy Ion Transport Code System Monte Carlo code package. Previously, it was reported that as a result of (16)O(p,2p2n)(13)N nuclear reaction, whose threshold energy is relatively low (5.660 MeV), a (13)N peak is formed near the actual Bragg peak. Considering the generated (13)N peak, we obtain offset distance values between the (13)N peak and the actual Bragg peak for various incident proton energies ranging from 45 to 250 MeV, with an energy interval of 5 MeV. The offset distances fluctuate between 1.0 and 2.0 mm. For example, the offset distances between the (13)N peak and the Bragg peak are 2.0, 2.0, and 1.0 mm for incident proton energies of 80, 160, and 240 MeV, respectively. These slight fluctuations for different incident proton energies are due to the relatively stable energy-dependent cross-section data for the (16)O(p,2p2n)(13)N nuclear reaction. Hence, we develop an open-source computer program that performs linear and non-linear interpolations of offset distance data against the incident proton energy, which further reduces the energy interval from 5 to 0.1 MeV. In addition, we perform spectral analysis to reconstruct the (13)N Bragg peak, and the results are consistent with those predicted from Monte Carlo computations. Hence, the results are used to generate three-dimensional scatter plots of the (13)N radionuclide distribution in the modeled phantom. The obtained results and the developed methodologies will facilitate future investigations into proton range monitoring for therapeutic applications. |
format | Online Article Text |
id | pubmed-8846528 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-88465282022-02-16 Proton range monitoring using (13)N peak for proton therapy applications Islam, M. Rafiqul Shahmohammadi Beni, Mehrdad Ng, Chor-yi Miyake, Masayasu Rahman, Mahabubur Ito, Shigeki Gotoh, Shinichi Yamaya, Taiga Watabe, Hiroshi PLoS One Research Article The Monte Carlo method is employed in this study to simulate the proton irradiation of a water-gel phantom. Positron-emitting radionuclides such as (11)C, (15)O, and (13)N are scored using the Particle and Heavy Ion Transport Code System Monte Carlo code package. Previously, it was reported that as a result of (16)O(p,2p2n)(13)N nuclear reaction, whose threshold energy is relatively low (5.660 MeV), a (13)N peak is formed near the actual Bragg peak. Considering the generated (13)N peak, we obtain offset distance values between the (13)N peak and the actual Bragg peak for various incident proton energies ranging from 45 to 250 MeV, with an energy interval of 5 MeV. The offset distances fluctuate between 1.0 and 2.0 mm. For example, the offset distances between the (13)N peak and the Bragg peak are 2.0, 2.0, and 1.0 mm for incident proton energies of 80, 160, and 240 MeV, respectively. These slight fluctuations for different incident proton energies are due to the relatively stable energy-dependent cross-section data for the (16)O(p,2p2n)(13)N nuclear reaction. Hence, we develop an open-source computer program that performs linear and non-linear interpolations of offset distance data against the incident proton energy, which further reduces the energy interval from 5 to 0.1 MeV. In addition, we perform spectral analysis to reconstruct the (13)N Bragg peak, and the results are consistent with those predicted from Monte Carlo computations. Hence, the results are used to generate three-dimensional scatter plots of the (13)N radionuclide distribution in the modeled phantom. The obtained results and the developed methodologies will facilitate future investigations into proton range monitoring for therapeutic applications. Public Library of Science 2022-02-15 /pmc/articles/PMC8846528/ /pubmed/35167589 http://dx.doi.org/10.1371/journal.pone.0263521 Text en © 2022 Islam et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Islam, M. Rafiqul Shahmohammadi Beni, Mehrdad Ng, Chor-yi Miyake, Masayasu Rahman, Mahabubur Ito, Shigeki Gotoh, Shinichi Yamaya, Taiga Watabe, Hiroshi Proton range monitoring using (13)N peak for proton therapy applications |
title | Proton range monitoring using (13)N peak for proton therapy applications |
title_full | Proton range monitoring using (13)N peak for proton therapy applications |
title_fullStr | Proton range monitoring using (13)N peak for proton therapy applications |
title_full_unstemmed | Proton range monitoring using (13)N peak for proton therapy applications |
title_short | Proton range monitoring using (13)N peak for proton therapy applications |
title_sort | proton range monitoring using (13)n peak for proton therapy applications |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8846528/ https://www.ncbi.nlm.nih.gov/pubmed/35167589 http://dx.doi.org/10.1371/journal.pone.0263521 |
work_keys_str_mv | AT islammrafiqul protonrangemonitoringusing13npeakforprotontherapyapplications AT shahmohammadibenimehrdad protonrangemonitoringusing13npeakforprotontherapyapplications AT ngchoryi protonrangemonitoringusing13npeakforprotontherapyapplications AT miyakemasayasu protonrangemonitoringusing13npeakforprotontherapyapplications AT rahmanmahabubur protonrangemonitoringusing13npeakforprotontherapyapplications AT itoshigeki protonrangemonitoringusing13npeakforprotontherapyapplications AT gotohshinichi protonrangemonitoringusing13npeakforprotontherapyapplications AT yamayataiga protonrangemonitoringusing13npeakforprotontherapyapplications AT watabehiroshi protonrangemonitoringusing13npeakforprotontherapyapplications |