Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables

BACKGROUND: Angiography and embolization (AE) is a lifesaving, high radiation dose procedure for treatment of abdominal arterial hemorrhage (AAH). Interventional radiologists have utilized pre-procedure CT angiography (CTA) and newer fluoroscopic systems in an attempt to reduce radiation dose and pr...

Descripción completa

Detalles Bibliográficos
Autores principales: McCaughey, Conor, Healy, Gerard M., Al Balushi, Hanin, Maher, Patrice, McCavana, Jackie, Lucey, Julie, Cantwell, Colin P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8850522/
https://www.ncbi.nlm.nih.gov/pubmed/35171363
http://dx.doi.org/10.1186/s42155-022-00284-4
_version_ 1784652617216950272
author McCaughey, Conor
Healy, Gerard M.
Al Balushi, Hanin
Maher, Patrice
McCavana, Jackie
Lucey, Julie
Cantwell, Colin P.
author_facet McCaughey, Conor
Healy, Gerard M.
Al Balushi, Hanin
Maher, Patrice
McCavana, Jackie
Lucey, Julie
Cantwell, Colin P.
author_sort McCaughey, Conor
collection PubMed
description BACKGROUND: Angiography and embolization (AE) is a lifesaving, high radiation dose procedure for treatment of abdominal arterial hemorrhage (AAH). Interventional radiologists have utilized pre-procedure CT angiography (CTA) and newer fluoroscopic systems in an attempt to reduce radiation dose and procedure time. PURPOSE: To study the factors contributing to the radiation dose of AE for AAH and to compare to the reference standard. MATERIALS AND METHODS: This retrospective single-centre observational cohort study identified 154 consecutive AE procedures in 138 patients (median age 65 years; interquartile range 54–77; 103 men) performed with a C-arm fluoroscopic system (Axiom Artis DTA or Axiom Artis Q (Siemens Healthineers)), between January 2010 and December 2017. Parameters analysed included: demographics, fluoroscopy system, bleeding location, body mass index (BMI), preprocedural CT, air kerma-area product (PKA), reference air kerma (K(a,r)), fluoroscopy time (FT) and the number of digital subtraction angiography (DSA) runs. Factors affecting dose were assessed using Mann–Whitney U, Kruskal–Wallis one-way ANOVA and linear regression. RESULTS: Patients treated with the new angiographic system (NS) had a median PKA, median K(a,r), Q3 PKA and Q3 K(a,r) that were 74% (p < 0.0005), 66%(p < 0.0005), 55% and 52% lower respectively than those treated with the old system (OS). This dose reduction was consistent for each bleeding location (upper GI, Lower GI and extraluminal). There was no difference in PKA (p = 0.452), K(a,r) (p = 0.974) or FT (p = 0.179), between those who did (n = 137) or did not (n = 17) undergo pre-procedure CTA. Other factors significantly influencing radiation dose were: patient BMI and number of DSA runs. A multivariate model containing these variables accounts for 15.2% of the variance in K(a,r) (p < 0.005) and 45.9% of the variance of PKA (p < 0.005). CONCLUSION: Radiation dose for AE in AAH is significantly reduced by new fluoroscopic technology. Higher patient body mass index is an independent key parameter affecting patient dose. Radiation dose was not influenced by haemorrhage site or performance of pre-procedure CTA.
format Online
Article
Text
id pubmed-8850522
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-88505222022-02-23 Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables McCaughey, Conor Healy, Gerard M. Al Balushi, Hanin Maher, Patrice McCavana, Jackie Lucey, Julie Cantwell, Colin P. CVIR Endovasc Original Article BACKGROUND: Angiography and embolization (AE) is a lifesaving, high radiation dose procedure for treatment of abdominal arterial hemorrhage (AAH). Interventional radiologists have utilized pre-procedure CT angiography (CTA) and newer fluoroscopic systems in an attempt to reduce radiation dose and procedure time. PURPOSE: To study the factors contributing to the radiation dose of AE for AAH and to compare to the reference standard. MATERIALS AND METHODS: This retrospective single-centre observational cohort study identified 154 consecutive AE procedures in 138 patients (median age 65 years; interquartile range 54–77; 103 men) performed with a C-arm fluoroscopic system (Axiom Artis DTA or Axiom Artis Q (Siemens Healthineers)), between January 2010 and December 2017. Parameters analysed included: demographics, fluoroscopy system, bleeding location, body mass index (BMI), preprocedural CT, air kerma-area product (PKA), reference air kerma (K(a,r)), fluoroscopy time (FT) and the number of digital subtraction angiography (DSA) runs. Factors affecting dose were assessed using Mann–Whitney U, Kruskal–Wallis one-way ANOVA and linear regression. RESULTS: Patients treated with the new angiographic system (NS) had a median PKA, median K(a,r), Q3 PKA and Q3 K(a,r) that were 74% (p < 0.0005), 66%(p < 0.0005), 55% and 52% lower respectively than those treated with the old system (OS). This dose reduction was consistent for each bleeding location (upper GI, Lower GI and extraluminal). There was no difference in PKA (p = 0.452), K(a,r) (p = 0.974) or FT (p = 0.179), between those who did (n = 137) or did not (n = 17) undergo pre-procedure CTA. Other factors significantly influencing radiation dose were: patient BMI and number of DSA runs. A multivariate model containing these variables accounts for 15.2% of the variance in K(a,r) (p < 0.005) and 45.9% of the variance of PKA (p < 0.005). CONCLUSION: Radiation dose for AE in AAH is significantly reduced by new fluoroscopic technology. Higher patient body mass index is an independent key parameter affecting patient dose. Radiation dose was not influenced by haemorrhage site or performance of pre-procedure CTA. Springer International Publishing 2022-02-16 /pmc/articles/PMC8850522/ /pubmed/35171363 http://dx.doi.org/10.1186/s42155-022-00284-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
McCaughey, Conor
Healy, Gerard M.
Al Balushi, Hanin
Maher, Patrice
McCavana, Jackie
Lucey, Julie
Cantwell, Colin P.
Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables
title Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables
title_full Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables
title_fullStr Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables
title_full_unstemmed Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables
title_short Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables
title_sort patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of ct angiography, fluoroscopy system, patient and procedural variables
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8850522/
https://www.ncbi.nlm.nih.gov/pubmed/35171363
http://dx.doi.org/10.1186/s42155-022-00284-4
work_keys_str_mv AT mccaugheyconor patientradiationdoseduringangiographyandembolizationforabdominalhemorrhagetheinfluenceofctangiographyfluoroscopysystempatientandproceduralvariables
AT healygerardm patientradiationdoseduringangiographyandembolizationforabdominalhemorrhagetheinfluenceofctangiographyfluoroscopysystempatientandproceduralvariables
AT albalushihanin patientradiationdoseduringangiographyandembolizationforabdominalhemorrhagetheinfluenceofctangiographyfluoroscopysystempatientandproceduralvariables
AT maherpatrice patientradiationdoseduringangiographyandembolizationforabdominalhemorrhagetheinfluenceofctangiographyfluoroscopysystempatientandproceduralvariables
AT mccavanajackie patientradiationdoseduringangiographyandembolizationforabdominalhemorrhagetheinfluenceofctangiographyfluoroscopysystempatientandproceduralvariables
AT luceyjulie patientradiationdoseduringangiographyandembolizationforabdominalhemorrhagetheinfluenceofctangiographyfluoroscopysystempatientandproceduralvariables
AT cantwellcolinp patientradiationdoseduringangiographyandembolizationforabdominalhemorrhagetheinfluenceofctangiographyfluoroscopysystempatientandproceduralvariables