Cargando…

Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients

Patients with end-stage renal disease develop changes in bone quality and quantity, which can be assessed using different methods. This study aimed to compare and to correlate bone parameters obtained in vivo using high-resolution peripheral quantitative computed tomography (HR-pQCT) with those obta...

Descripción completa

Detalles Bibliográficos
Autores principales: Pichone, Alinie, Gomes, Carlos Perez, Lima, Luis Felipe Cardoso, Moreira, Carolina Aguiar, Paranhos-Neto, Francisco de Paula, Madeira, Miguel, Lopes, Ricardo Tadeu, Farias, Maria Lucia Fleiuss, Leite Jr., Maurilo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8850668/
https://www.ncbi.nlm.nih.gov/pubmed/35198659
http://dx.doi.org/10.1016/j.bonr.2022.101173
_version_ 1784652649466953728
author Pichone, Alinie
Gomes, Carlos Perez
Lima, Luis Felipe Cardoso
Moreira, Carolina Aguiar
Paranhos-Neto, Francisco de Paula
Madeira, Miguel
Lopes, Ricardo Tadeu
Farias, Maria Lucia Fleiuss
Leite Jr., Maurilo
author_facet Pichone, Alinie
Gomes, Carlos Perez
Lima, Luis Felipe Cardoso
Moreira, Carolina Aguiar
Paranhos-Neto, Francisco de Paula
Madeira, Miguel
Lopes, Ricardo Tadeu
Farias, Maria Lucia Fleiuss
Leite Jr., Maurilo
author_sort Pichone, Alinie
collection PubMed
description Patients with end-stage renal disease develop changes in bone quality and quantity, which can be assessed using different methods. This study aimed to compare and to correlate bone parameters obtained in vivo using high-resolution peripheral quantitative computed tomography (HR-pQCT) with those obtained by bone biopsy using histomorphometry and microcomputed tomography (microCT) analysis of the iliac crest core, and to evaluate if HR-pQCT is helpful in aiding with categorization of those with high turnover. Twenty hemodialysis patients, 13 females (7 postmenopausal), underwent bone biopsy from 2018 to 2020. The mean age was 48.5 ± 10.6 years, and the mean hemodialysis vintage was 15 years. Histomorphometry identified mineralization defects, low turnover, and high turnover in 65%, 45%, and 35% of the patients, respectively. The highest values of trabecular bone volume (BV/TV) were obtained by histomorphometry, while the highest values of cortical thickness (Ct.Th) were obtained by HR-pQCT at the distal tibia. Moderate correlations were found between BV/TV values obtained by microCT of the bone core and HR-pQCT at the distal radius (r = 0.531, p = 0.016) and at the distal tibia (r = 0.536, p = 0.015). BV/TV values obtained from the bone core by histomorphometry and microCT were also significantly correlated (r = 0.475, p = 0.04). Regarding Ct.Th, there was a strong correlation between the radius and tibia HR-pQCT (r = 0.800, p < 0.001), between bone core microCT and the distal radius HR-pQCT (r = 0.610, p < 0.01), as between histomorphometry and microCT (r = 0.899, p < 0.01). In groups classified by bone turnover, patients with high turnover presented lower BV/TV, Tb.N, Tb.Th, and Ct.Th than those with low turnover in peripheral sites using HR-pQCT. By this method, it was possible to identify low turnover from tibia BV/TV > 12,4% plus Tb.Sp ≤ 0.667 mm (AUC 0.810, 95% CI 0.575 to 0.948) and high turnover from total bone mineral density (BMD) ≤ 154.2 mg HA/cm(3) (AUC 0.860, 95% CI 0.633 to 0.982, p < 0.001) and cortical BMD ≤ 691.6 mg HA/cm(3) (AUC 0.840, 95% CI 0.609 to 0.963, p < 0.001). In conclusion, HR-pQCT had significant correlation with iliac crest bone in BV/TV and Ct.Th, which are known to provide bone strength. This method is quick and non-invasive and may be helpful in categorizing those with high versus low turnover in hemodialysis patients.
format Online
Article
Text
id pubmed-8850668
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-88506682022-02-22 Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients Pichone, Alinie Gomes, Carlos Perez Lima, Luis Felipe Cardoso Moreira, Carolina Aguiar Paranhos-Neto, Francisco de Paula Madeira, Miguel Lopes, Ricardo Tadeu Farias, Maria Lucia Fleiuss Leite Jr., Maurilo Bone Rep Full Length Article Patients with end-stage renal disease develop changes in bone quality and quantity, which can be assessed using different methods. This study aimed to compare and to correlate bone parameters obtained in vivo using high-resolution peripheral quantitative computed tomography (HR-pQCT) with those obtained by bone biopsy using histomorphometry and microcomputed tomography (microCT) analysis of the iliac crest core, and to evaluate if HR-pQCT is helpful in aiding with categorization of those with high turnover. Twenty hemodialysis patients, 13 females (7 postmenopausal), underwent bone biopsy from 2018 to 2020. The mean age was 48.5 ± 10.6 years, and the mean hemodialysis vintage was 15 years. Histomorphometry identified mineralization defects, low turnover, and high turnover in 65%, 45%, and 35% of the patients, respectively. The highest values of trabecular bone volume (BV/TV) were obtained by histomorphometry, while the highest values of cortical thickness (Ct.Th) were obtained by HR-pQCT at the distal tibia. Moderate correlations were found between BV/TV values obtained by microCT of the bone core and HR-pQCT at the distal radius (r = 0.531, p = 0.016) and at the distal tibia (r = 0.536, p = 0.015). BV/TV values obtained from the bone core by histomorphometry and microCT were also significantly correlated (r = 0.475, p = 0.04). Regarding Ct.Th, there was a strong correlation between the radius and tibia HR-pQCT (r = 0.800, p < 0.001), between bone core microCT and the distal radius HR-pQCT (r = 0.610, p < 0.01), as between histomorphometry and microCT (r = 0.899, p < 0.01). In groups classified by bone turnover, patients with high turnover presented lower BV/TV, Tb.N, Tb.Th, and Ct.Th than those with low turnover in peripheral sites using HR-pQCT. By this method, it was possible to identify low turnover from tibia BV/TV > 12,4% plus Tb.Sp ≤ 0.667 mm (AUC 0.810, 95% CI 0.575 to 0.948) and high turnover from total bone mineral density (BMD) ≤ 154.2 mg HA/cm(3) (AUC 0.860, 95% CI 0.633 to 0.982, p < 0.001) and cortical BMD ≤ 691.6 mg HA/cm(3) (AUC 0.840, 95% CI 0.609 to 0.963, p < 0.001). In conclusion, HR-pQCT had significant correlation with iliac crest bone in BV/TV and Ct.Th, which are known to provide bone strength. This method is quick and non-invasive and may be helpful in categorizing those with high versus low turnover in hemodialysis patients. Elsevier 2022-02-11 /pmc/articles/PMC8850668/ /pubmed/35198659 http://dx.doi.org/10.1016/j.bonr.2022.101173 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Full Length Article
Pichone, Alinie
Gomes, Carlos Perez
Lima, Luis Felipe Cardoso
Moreira, Carolina Aguiar
Paranhos-Neto, Francisco de Paula
Madeira, Miguel
Lopes, Ricardo Tadeu
Farias, Maria Lucia Fleiuss
Leite Jr., Maurilo
Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients
title Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients
title_full Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients
title_fullStr Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients
title_full_unstemmed Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients
title_short Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients
title_sort assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microct of iliac crest bone core in hemodialysis patients
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8850668/
https://www.ncbi.nlm.nih.gov/pubmed/35198659
http://dx.doi.org/10.1016/j.bonr.2022.101173
work_keys_str_mv AT pichonealinie assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients
AT gomescarlosperez assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients
AT limaluisfelipecardoso assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients
AT moreiracarolinaaguiar assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients
AT paranhosnetofranciscodepaula assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients
AT madeiramiguel assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients
AT lopesricardotadeu assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients
AT fariasmarialuciafleiuss assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients
AT leitejrmaurilo assessmentoftrabecularandcorticalparametersusinghighresolutionperipheralquantitativecomputedtomographyhistomorphometryandmicroctofiliaccrestbonecoreinhemodialysispatients