Cargando…

Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study

Walking-induced fluctuations have a significant influence on indoor airflow and pollutant dispersion. This study developed a method to quantify the robustness of ventilation systems in the control of walking-induced fluctuation control. Experiments were conducted in a full-scale chamber with four di...

Descripción completa

Detalles Bibliográficos
Autores principales: Ren, Jianlin, He, Junjie, Kong, Xiangfei, Li, Hongwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tsinghua University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8854482/
https://www.ncbi.nlm.nih.gov/pubmed/35194487
http://dx.doi.org/10.1007/s12273-022-0888-x
_version_ 1784653448186167296
author Ren, Jianlin
He, Junjie
Kong, Xiangfei
Li, Hongwan
author_facet Ren, Jianlin
He, Junjie
Kong, Xiangfei
Li, Hongwan
author_sort Ren, Jianlin
collection PubMed
description Walking-induced fluctuations have a significant influence on indoor airflow and pollutant dispersion. This study developed a method to quantify the robustness of ventilation systems in the control of walking-induced fluctuation control. Experiments were conducted in a full-scale chamber with four different kinds of ventilation systems: ceiling supply and side return (CS), ceiling supply and ceiling return (CC), side supply and ceiling return (SC), and side supply and side return (SS). The measured temperature, flow and pollutant field data was (1) denoised by FFT filtering or wavelet transform; (2) fitted by a Gaussian function; (3) feature-extracted for the range and time scale disturbance; and then (4) used to calculate the range scale and time scale robustness for different ventilation systems with dimensionless equations developed in this study. The selection processes for FFT filtering and wavelet transform, FFT filter cut-off frequency, wavelet function, and decomposition layers are also discussed, as well as the threshold for wavelet denoising, which can be adjusted accordingly if the walking frequency or sampling frequency differs from that in other studies. The results show that for the flow and pollutant fields, the use of a ventilation system can increase the range scale robustness by 19.7%–39.4% and 10.0%–38.8%, respectively; and the SS system was 7.0%–25.7% more robust than the other three ventilation systems. However, all four kinds of ventilation systems had a very limited effect in controlling the time scale disturbance.
format Online
Article
Text
id pubmed-8854482
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Tsinghua University Press
record_format MEDLINE/PubMed
spelling pubmed-88544822022-02-18 Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study Ren, Jianlin He, Junjie Kong, Xiangfei Li, Hongwan Build Simul Research Article Walking-induced fluctuations have a significant influence on indoor airflow and pollutant dispersion. This study developed a method to quantify the robustness of ventilation systems in the control of walking-induced fluctuation control. Experiments were conducted in a full-scale chamber with four different kinds of ventilation systems: ceiling supply and side return (CS), ceiling supply and ceiling return (CC), side supply and ceiling return (SC), and side supply and side return (SS). The measured temperature, flow and pollutant field data was (1) denoised by FFT filtering or wavelet transform; (2) fitted by a Gaussian function; (3) feature-extracted for the range and time scale disturbance; and then (4) used to calculate the range scale and time scale robustness for different ventilation systems with dimensionless equations developed in this study. The selection processes for FFT filtering and wavelet transform, FFT filter cut-off frequency, wavelet function, and decomposition layers are also discussed, as well as the threshold for wavelet denoising, which can be adjusted accordingly if the walking frequency or sampling frequency differs from that in other studies. The results show that for the flow and pollutant fields, the use of a ventilation system can increase the range scale robustness by 19.7%–39.4% and 10.0%–38.8%, respectively; and the SS system was 7.0%–25.7% more robust than the other three ventilation systems. However, all four kinds of ventilation systems had a very limited effect in controlling the time scale disturbance. Tsinghua University Press 2022-02-18 2022 /pmc/articles/PMC8854482/ /pubmed/35194487 http://dx.doi.org/10.1007/s12273-022-0888-x Text en © Tsinghua University Press 2022 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Research Article
Ren, Jianlin
He, Junjie
Kong, Xiangfei
Li, Hongwan
Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study
title Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study
title_full Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study
title_fullStr Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study
title_full_unstemmed Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study
title_short Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study
title_sort robustness of ventilation systems in the control of walking-induced indoor fluctuations: method development and case study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8854482/
https://www.ncbi.nlm.nih.gov/pubmed/35194487
http://dx.doi.org/10.1007/s12273-022-0888-x
work_keys_str_mv AT renjianlin robustnessofventilationsystemsinthecontrolofwalkinginducedindoorfluctuationsmethoddevelopmentandcasestudy
AT hejunjie robustnessofventilationsystemsinthecontrolofwalkinginducedindoorfluctuationsmethoddevelopmentandcasestudy
AT kongxiangfei robustnessofventilationsystemsinthecontrolofwalkinginducedindoorfluctuationsmethoddevelopmentandcasestudy
AT lihongwan robustnessofventilationsystemsinthecontrolofwalkinginducedindoorfluctuationsmethoddevelopmentandcasestudy