Cargando…

A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale

During intraocular lens (IOL) implantation it is not uncommon for the injector’s nozzle-tip to get damaged. However, the damage has not been systematically described or evaluated using an objective scale. In this study we developed our own system—the Heidelberg Score for IOL Injector Damage (“HeiSco...

Descripción completa

Detalles Bibliográficos
Autores principales: Fang, Hui, Zhang, Lu, Schickhardt, Sonja, Merz, Patrick R., Yan, Weijia, Leroux, Mélanie, Auffarth, Gerd U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8854687/
https://www.ncbi.nlm.nih.gov/pubmed/35177741
http://dx.doi.org/10.1038/s41598-022-06696-5
_version_ 1784653482984210432
author Fang, Hui
Zhang, Lu
Schickhardt, Sonja
Merz, Patrick R.
Yan, Weijia
Leroux, Mélanie
Auffarth, Gerd U.
author_facet Fang, Hui
Zhang, Lu
Schickhardt, Sonja
Merz, Patrick R.
Yan, Weijia
Leroux, Mélanie
Auffarth, Gerd U.
author_sort Fang, Hui
collection PubMed
description During intraocular lens (IOL) implantation it is not uncommon for the injector’s nozzle-tip to get damaged. However, the damage has not been systematically described or evaluated using an objective scale. In this study we developed our own system—the Heidelberg Score for IOL Injector Damage (“HeiScore”), which was used to grade 60 injectors from four generations of injector models (Monarch III D, AcrySert C, UltraSert, AutonoMe) made by the same manufacturer. (Alcon Laboratories Inc.) HeiScore has six grades of nozzle-tip damage: no damage (which was graded 0); slight scratches (1), deep scratches (2), extensions (3), cracks (4) and bursts (graded number 5). The score for each injector model was the sum of all grades (total number), and we could compare the four injector models. The injectors showed varying damage profiles, from “no damage” to “crack”. A tendency of a lower damage score in the newer generations of IOL injectors was noted. However, a statistically significant difference was observed only between Monarch III D and AutonoMe. The “Heidelberg Score for IOL Injector Damage” could efficiently and effectively evaluate the damage to IOL injector systems, which might help manufacturers optimize the positioning of the IOL in the injector during pre-loading.
format Online
Article
Text
id pubmed-8854687
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-88546872022-02-18 A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale Fang, Hui Zhang, Lu Schickhardt, Sonja Merz, Patrick R. Yan, Weijia Leroux, Mélanie Auffarth, Gerd U. Sci Rep Article During intraocular lens (IOL) implantation it is not uncommon for the injector’s nozzle-tip to get damaged. However, the damage has not been systematically described or evaluated using an objective scale. In this study we developed our own system—the Heidelberg Score for IOL Injector Damage (“HeiScore”), which was used to grade 60 injectors from four generations of injector models (Monarch III D, AcrySert C, UltraSert, AutonoMe) made by the same manufacturer. (Alcon Laboratories Inc.) HeiScore has six grades of nozzle-tip damage: no damage (which was graded 0); slight scratches (1), deep scratches (2), extensions (3), cracks (4) and bursts (graded number 5). The score for each injector model was the sum of all grades (total number), and we could compare the four injector models. The injectors showed varying damage profiles, from “no damage” to “crack”. A tendency of a lower damage score in the newer generations of IOL injectors was noted. However, a statistically significant difference was observed only between Monarch III D and AutonoMe. The “Heidelberg Score for IOL Injector Damage” could efficiently and effectively evaluate the damage to IOL injector systems, which might help manufacturers optimize the positioning of the IOL in the injector during pre-loading. Nature Publishing Group UK 2022-02-17 /pmc/articles/PMC8854687/ /pubmed/35177741 http://dx.doi.org/10.1038/s41598-022-06696-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Fang, Hui
Zhang, Lu
Schickhardt, Sonja
Merz, Patrick R.
Yan, Weijia
Leroux, Mélanie
Auffarth, Gerd U.
A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale
title A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale
title_full A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale
title_fullStr A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale
title_full_unstemmed A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale
title_short A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale
title_sort laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8854687/
https://www.ncbi.nlm.nih.gov/pubmed/35177741
http://dx.doi.org/10.1038/s41598-022-06696-5
work_keys_str_mv AT fanghui alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT zhanglu alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT schickhardtsonja alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT merzpatrickr alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT yanweijia alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT lerouxmelanie alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT auffarthgerdu alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT fanghui laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT zhanglu laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT schickhardtsonja laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT merzpatrickr laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT yanweijia laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT lerouxmelanie laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale
AT auffarthgerdu laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale