A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale
During intraocular lens (IOL) implantation it is not uncommon for the injector’s nozzle-tip to get damaged. However, the damage has not been systematically described or evaluated using an objective scale. In this study we developed our own system—the Heidelberg Score for IOL Injector Damage (“HeiSco...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8854687/ https://www.ncbi.nlm.nih.gov/pubmed/35177741 http://dx.doi.org/10.1038/s41598-022-06696-5 |
_version_ | 1784653482984210432 |
---|---|
author | Fang, Hui Zhang, Lu Schickhardt, Sonja Merz, Patrick R. Yan, Weijia Leroux, Mélanie Auffarth, Gerd U. |
author_facet | Fang, Hui Zhang, Lu Schickhardt, Sonja Merz, Patrick R. Yan, Weijia Leroux, Mélanie Auffarth, Gerd U. |
author_sort | Fang, Hui |
collection | PubMed |
description | During intraocular lens (IOL) implantation it is not uncommon for the injector’s nozzle-tip to get damaged. However, the damage has not been systematically described or evaluated using an objective scale. In this study we developed our own system—the Heidelberg Score for IOL Injector Damage (“HeiScore”), which was used to grade 60 injectors from four generations of injector models (Monarch III D, AcrySert C, UltraSert, AutonoMe) made by the same manufacturer. (Alcon Laboratories Inc.) HeiScore has six grades of nozzle-tip damage: no damage (which was graded 0); slight scratches (1), deep scratches (2), extensions (3), cracks (4) and bursts (graded number 5). The score for each injector model was the sum of all grades (total number), and we could compare the four injector models. The injectors showed varying damage profiles, from “no damage” to “crack”. A tendency of a lower damage score in the newer generations of IOL injectors was noted. However, a statistically significant difference was observed only between Monarch III D and AutonoMe. The “Heidelberg Score for IOL Injector Damage” could efficiently and effectively evaluate the damage to IOL injector systems, which might help manufacturers optimize the positioning of the IOL in the injector during pre-loading. |
format | Online Article Text |
id | pubmed-8854687 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-88546872022-02-18 A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale Fang, Hui Zhang, Lu Schickhardt, Sonja Merz, Patrick R. Yan, Weijia Leroux, Mélanie Auffarth, Gerd U. Sci Rep Article During intraocular lens (IOL) implantation it is not uncommon for the injector’s nozzle-tip to get damaged. However, the damage has not been systematically described or evaluated using an objective scale. In this study we developed our own system—the Heidelberg Score for IOL Injector Damage (“HeiScore”), which was used to grade 60 injectors from four generations of injector models (Monarch III D, AcrySert C, UltraSert, AutonoMe) made by the same manufacturer. (Alcon Laboratories Inc.) HeiScore has six grades of nozzle-tip damage: no damage (which was graded 0); slight scratches (1), deep scratches (2), extensions (3), cracks (4) and bursts (graded number 5). The score for each injector model was the sum of all grades (total number), and we could compare the four injector models. The injectors showed varying damage profiles, from “no damage” to “crack”. A tendency of a lower damage score in the newer generations of IOL injectors was noted. However, a statistically significant difference was observed only between Monarch III D and AutonoMe. The “Heidelberg Score for IOL Injector Damage” could efficiently and effectively evaluate the damage to IOL injector systems, which might help manufacturers optimize the positioning of the IOL in the injector during pre-loading. Nature Publishing Group UK 2022-02-17 /pmc/articles/PMC8854687/ /pubmed/35177741 http://dx.doi.org/10.1038/s41598-022-06696-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Fang, Hui Zhang, Lu Schickhardt, Sonja Merz, Patrick R. Yan, Weijia Leroux, Mélanie Auffarth, Gerd U. A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale |
title | A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale |
title_full | A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale |
title_fullStr | A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale |
title_full_unstemmed | A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale |
title_short | A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale |
title_sort | laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8854687/ https://www.ncbi.nlm.nih.gov/pubmed/35177741 http://dx.doi.org/10.1038/s41598-022-06696-5 |
work_keys_str_mv | AT fanghui alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT zhanglu alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT schickhardtsonja alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT merzpatrickr alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT yanweijia alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT lerouxmelanie alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT auffarthgerdu alaboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT fanghui laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT zhanglu laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT schickhardtsonja laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT merzpatrickr laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT yanweijia laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT lerouxmelanie laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale AT auffarthgerdu laboratoryevaluationofnozzletipdamageinfourgenerationsofintraocularlensinjectorsystemsusingaselfdevelopeddamagescale |