The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study

BACKGROUND: Given the potential benefits of introducing ultrasound in the clinical assessment of muscle disorders, this study aimed to assess the feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric clinical setting. METHODS: Cross-sectional pilot study in 2...

Descripción completa

Detalles Bibliográficos
Autores principales: Meza-Valderrama, Delky, Sánchez- Rodríguez, Dolores, Perkisas, Stany, Duran, Xavi, Bastijns, Sophie, Dávalos-Yerovi, Vanesa, Da Costa, Elizabeth, Marco, Ester
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8855585/
https://www.ncbi.nlm.nih.gov/pubmed/35177006
http://dx.doi.org/10.1186/s12877-022-02811-3
_version_ 1784653682445385728
author Meza-Valderrama, Delky
Sánchez- Rodríguez, Dolores
Perkisas, Stany
Duran, Xavi
Bastijns, Sophie
Dávalos-Yerovi, Vanesa
Da Costa, Elizabeth
Marco, Ester
author_facet Meza-Valderrama, Delky
Sánchez- Rodríguez, Dolores
Perkisas, Stany
Duran, Xavi
Bastijns, Sophie
Dávalos-Yerovi, Vanesa
Da Costa, Elizabeth
Marco, Ester
author_sort Meza-Valderrama, Delky
collection PubMed
description BACKGROUND: Given the potential benefits of introducing ultrasound in the clinical assessment of muscle disorders, this study aimed to assess the feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric clinical setting. METHODS: Cross-sectional pilot study in 25 participants (12 patients aged ≥ 70 years in an acute geriatric ward and 13 healthy volunteers aged 25–50 years), assessed by three raters. Muscle thickness measurement was estimated as the distance between the subcutaneous adipose tissue-muscle interface and muscle-bone interface of the radius at 30% proximal of the distance between the styloid process and distal insertion of the biceps brachii muscle of the dominant forearm. Examinations were repeated three times by each rater and intra- and inter-rater reliability was calculated. Feasibility analysis included consideration of technological, economic, legal, operational, and scheduling (TELOS) components. RESULTS: Mean muscle-thickness measurement difference between groups was 4.4 mm (95% confidence interval [CI] 2.4 mm to 6.3 mm], p < 0.001). Intra-rater reliability of muscle-thickness assessment was excellent, with intraclass correlation coefficient (ICC) of 0.947 (95%CI 0.902 to 0.974), 0.969 (95%CI 0.942 to 0.985), and 0.950 (95%CI 0.907 to 0.975) for observer A, B, and C, respectively. Inter-rater comparison showed good agreement (ICC of 0.873 [95%CI 0.73 to 0.94]). Four of the 17 TELOS components considered led to specific recommendations to improve the procedure’s feasibility in clinical practice. CONCLUSION: Our findings suggest that US is a feasible tool to assess the thickness of the forearm muscles with good inter-rater and excellent intra-rater reliability in a sample of hospitalized geriatric patients, making it a promising option for use in clinical practice.
format Online
Article
Text
id pubmed-8855585
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-88555852022-02-23 The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study Meza-Valderrama, Delky Sánchez- Rodríguez, Dolores Perkisas, Stany Duran, Xavi Bastijns, Sophie Dávalos-Yerovi, Vanesa Da Costa, Elizabeth Marco, Ester BMC Geriatr Research BACKGROUND: Given the potential benefits of introducing ultrasound in the clinical assessment of muscle disorders, this study aimed to assess the feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric clinical setting. METHODS: Cross-sectional pilot study in 25 participants (12 patients aged ≥ 70 years in an acute geriatric ward and 13 healthy volunteers aged 25–50 years), assessed by three raters. Muscle thickness measurement was estimated as the distance between the subcutaneous adipose tissue-muscle interface and muscle-bone interface of the radius at 30% proximal of the distance between the styloid process and distal insertion of the biceps brachii muscle of the dominant forearm. Examinations were repeated three times by each rater and intra- and inter-rater reliability was calculated. Feasibility analysis included consideration of technological, economic, legal, operational, and scheduling (TELOS) components. RESULTS: Mean muscle-thickness measurement difference between groups was 4.4 mm (95% confidence interval [CI] 2.4 mm to 6.3 mm], p < 0.001). Intra-rater reliability of muscle-thickness assessment was excellent, with intraclass correlation coefficient (ICC) of 0.947 (95%CI 0.902 to 0.974), 0.969 (95%CI 0.942 to 0.985), and 0.950 (95%CI 0.907 to 0.975) for observer A, B, and C, respectively. Inter-rater comparison showed good agreement (ICC of 0.873 [95%CI 0.73 to 0.94]). Four of the 17 TELOS components considered led to specific recommendations to improve the procedure’s feasibility in clinical practice. CONCLUSION: Our findings suggest that US is a feasible tool to assess the thickness of the forearm muscles with good inter-rater and excellent intra-rater reliability in a sample of hospitalized geriatric patients, making it a promising option for use in clinical practice. BioMed Central 2022-02-18 /pmc/articles/PMC8855585/ /pubmed/35177006 http://dx.doi.org/10.1186/s12877-022-02811-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Meza-Valderrama, Delky
Sánchez- Rodríguez, Dolores
Perkisas, Stany
Duran, Xavi
Bastijns, Sophie
Dávalos-Yerovi, Vanesa
Da Costa, Elizabeth
Marco, Ester
The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_full The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_fullStr The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_full_unstemmed The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_short The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_sort feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8855585/
https://www.ncbi.nlm.nih.gov/pubmed/35177006
http://dx.doi.org/10.1186/s12877-022-02811-3
work_keys_str_mv AT mezavalderramadelky thefeasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT sanchezrodriguezdolores thefeasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT perkisasstany thefeasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT duranxavi thefeasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT bastijnssophie thefeasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT davalosyerovivanesa thefeasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT dacostaelizabeth thefeasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT marcoester thefeasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT mezavalderramadelky feasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT sanchezrodriguezdolores feasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT perkisasstany feasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT duranxavi feasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT bastijnssophie feasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT davalosyerovivanesa feasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT dacostaelizabeth feasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy
AT marcoester feasibilityandreliabilityofmeasuringforearmmusclethicknessbyultrasoundinageriatricinpatientsettingacrosssectionalpilotstudy