Implementation of an Online Glaucoma-Specific Quality of Life Computerized Adaptive Test System in a US Glaucoma Hospital
PURPOSE: The feasibility of implementing a computerized adaptive test (CAT) system in routine clinical care in ophthalmology has not been assessed. We evaluated the implementation of a glaucoma-specific CAT (GlauCAT) in outpatients at Massachusetts Eye and Ear Institute. METHODS: In this implementat...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8857615/ https://www.ncbi.nlm.nih.gov/pubmed/35171226 http://dx.doi.org/10.1167/tvst.11.2.24 |
Sumario: | PURPOSE: The feasibility of implementing a computerized adaptive test (CAT) system in routine clinical care in ophthalmology has not been assessed. We evaluated the implementation of a glaucoma-specific CAT (GlauCAT) in outpatients at Massachusetts Eye and Ear Institute. METHODS: In this implementation study (July 2020–April 2021), 216 adults (mean ± SD age 64.8 ± 15.3 years; 56.0% women) completed six adaptive GlauCAT quality of life (QOL) tests on an internet-enabled tablet at the clinic. A real-time printable report summarizing domain scores was shared with physicians prior to consultation. The implementation was evaluated using Proctor's outcomes: acceptability (patient satisfaction); appropriateness (independent complete rate [%]); feasibility (acceptance rate [%]; completion time); and fidelity (percentage of patients discussing GlauCAT results with their physician). Physician barriers/facilitators were explored using open-ended questions. RESULTS: Patients’ mean ± SD satisfaction score was 3.5 ± 0.5 of 4, with >95% of patients willing to recommend it to others. Of the 216 (89.2%) patients accepting to participate, 173 (80%) completed GlauCAT independently. Patients took 8 minutes and 5 seconds (median) to complete all 6 GlauCAT tests. Almost two-thirds (n = 136/216) of the patients reported discussing their GlauCAT results with their doctor. Physicians described the GlauCAT summary report as helpful and user-friendly, although lack of time and uncertainty about how to action information were reported. CONCLUSIONS: Pilot implementation of six GlauCAT QOL tests in glaucoma outpatient clinics was feasible and acceptable. Integration of GlauCAT with electronic medical records (EMRs) and evaluation of long-term implementation outcomes are needed. TRANSLATIONAL RELEVANCE: GlauCAT's multiple outcomes and low test-taking burden makes it attractive for measuring glaucoma-specific QOL in routine clinical care. |
---|