Cargando…

Novel Use of Catheter Mount as an Alternative to T-piece

Catheter mounts with swivel connectors are used to attach the endotracheal tube to the ventilator circuit, dampening jerks and drags and increasing patient comfort. We suggest a unique application of catheter mount as T-piece for weaning, eliminating the need for a single inventory purchase and repu...

Descripción completa

Detalles Bibliográficos
Autores principales: Anand, Abhijeet, Panda, Rajesh, Kodamanchili, Saiteja, Saigal, Saurabh, TB, Gowthaman, Bhardwaj, Krishnkant
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8857724/
https://www.ncbi.nlm.nih.gov/pubmed/35712728
http://dx.doi.org/10.5005/jp-journals-10071-24114
_version_ 1784654099924385792
author Anand, Abhijeet
Panda, Rajesh
Kodamanchili, Saiteja
Saigal, Saurabh
TB, Gowthaman
Bhardwaj, Krishnkant
author_facet Anand, Abhijeet
Panda, Rajesh
Kodamanchili, Saiteja
Saigal, Saurabh
TB, Gowthaman
Bhardwaj, Krishnkant
author_sort Anand, Abhijeet
collection PubMed
description Catheter mounts with swivel connectors are used to attach the endotracheal tube to the ventilator circuit, dampening jerks and drags and increasing patient comfort. We suggest a unique application of catheter mount as T-piece for weaning, eliminating the need for a single inventory purchase and repurposing a previously used item for a new use, lowering the financial burden on patients. In our ICU, catheter mounts are being used as an alternative to T-piece for 30-minute weaning trials following successful SBT trials to evaluate patients’ response to Zero PEEP (ZEEP) and therefore the probable occurrence of alveolar derecruitment to decrease extubation failure. HOW TO CITE THIS ARTICLE: Anand A, Panda R, Kodamanchili S, Saigal S, Gowthaman TB, Bhardwaj K. Novel Use of Catheter Mount as an Alternative to T-piece. Indian J Crit Care Med 2022;26(2):246–247.
format Online
Article
Text
id pubmed-8857724
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-88577242022-06-15 Novel Use of Catheter Mount as an Alternative to T-piece Anand, Abhijeet Panda, Rajesh Kodamanchili, Saiteja Saigal, Saurabh TB, Gowthaman Bhardwaj, Krishnkant Indian J Crit Care Med Letter to the Editor Catheter mounts with swivel connectors are used to attach the endotracheal tube to the ventilator circuit, dampening jerks and drags and increasing patient comfort. We suggest a unique application of catheter mount as T-piece for weaning, eliminating the need for a single inventory purchase and repurposing a previously used item for a new use, lowering the financial burden on patients. In our ICU, catheter mounts are being used as an alternative to T-piece for 30-minute weaning trials following successful SBT trials to evaluate patients’ response to Zero PEEP (ZEEP) and therefore the probable occurrence of alveolar derecruitment to decrease extubation failure. HOW TO CITE THIS ARTICLE: Anand A, Panda R, Kodamanchili S, Saigal S, Gowthaman TB, Bhardwaj K. Novel Use of Catheter Mount as an Alternative to T-piece. Indian J Crit Care Med 2022;26(2):246–247. Jaypee Brothers Medical Publishers 2022-02 /pmc/articles/PMC8857724/ /pubmed/35712728 http://dx.doi.org/10.5005/jp-journals-10071-24114 Text en Copyright © 2022; The Author(s). https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Letter to the Editor
Anand, Abhijeet
Panda, Rajesh
Kodamanchili, Saiteja
Saigal, Saurabh
TB, Gowthaman
Bhardwaj, Krishnkant
Novel Use of Catheter Mount as an Alternative to T-piece
title Novel Use of Catheter Mount as an Alternative to T-piece
title_full Novel Use of Catheter Mount as an Alternative to T-piece
title_fullStr Novel Use of Catheter Mount as an Alternative to T-piece
title_full_unstemmed Novel Use of Catheter Mount as an Alternative to T-piece
title_short Novel Use of Catheter Mount as an Alternative to T-piece
title_sort novel use of catheter mount as an alternative to t-piece
topic Letter to the Editor
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8857724/
https://www.ncbi.nlm.nih.gov/pubmed/35712728
http://dx.doi.org/10.5005/jp-journals-10071-24114
work_keys_str_mv AT anandabhijeet noveluseofcathetermountasanalternativetotpiece
AT pandarajesh noveluseofcathetermountasanalternativetotpiece
AT kodamanchilisaiteja noveluseofcathetermountasanalternativetotpiece
AT saigalsaurabh noveluseofcathetermountasanalternativetotpiece
AT tbgowthaman noveluseofcathetermountasanalternativetotpiece
AT bhardwajkrishnkant noveluseofcathetermountasanalternativetotpiece