Different performance of three point-of-care SARS-CoV-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study

OBJECTIVES: PCR on nasopharyngeal exudates, the cornerstone of the detection of SARS-CoV-2, is time-consuming and commonly unavailable at primary health care centres. Detection of viral nucleocapsid antigens using lateral flow point-of-care tests is helpful for the early triage of patients who atten...

Descripción completa

Detalles Bibliográficos
Autores principales: Escribano, Pilar, Sánchez-Pulido, Ana-Erika, González-Leiva, José, Valero-López, Iván, Catalán, Pilar, Muñoz, Patricia, Guinea, Jesús
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8858772/
https://www.ncbi.nlm.nih.gov/pubmed/35202788
http://dx.doi.org/10.1016/j.cmi.2022.02.014
_version_ 1784654307555016704
author Escribano, Pilar
Sánchez-Pulido, Ana-Erika
González-Leiva, José
Valero-López, Iván
Catalán, Pilar
Muñoz, Patricia
Guinea, Jesús
author_facet Escribano, Pilar
Sánchez-Pulido, Ana-Erika
González-Leiva, José
Valero-López, Iván
Catalán, Pilar
Muñoz, Patricia
Guinea, Jesús
author_sort Escribano, Pilar
collection PubMed
description OBJECTIVES: PCR on nasopharyngeal exudates, the cornerstone of the detection of SARS-CoV-2, is time-consuming and commonly unavailable at primary health care centres. Detection of viral nucleocapsid antigens using lateral flow point-of-care tests is helpful for the early triage of patients who attend health care facilities. METHODS: This was a prospective study carried out in clinically suspected cases and close asymptomatic contacts who attended a primary care centre (Madrid, Spain) for SARS-CoV-2 detection. Patients were divided into three 300-patient cohorts (n = 200 symptomatic cases and n = 100 close asymptomatic contacts per cohort). Three antigen detection tests (SGTI-Flex COVID-19 Ag, Panbio COVID-19 Ag Rapid Test Device, and GSD NovaGen SARS-CoV-2 Ag Rapid Test) were used and compared. Paired nasopharyngeal exudates were obtained, one swab for PCR and the other for antigen detection. Each antigen detection test was evaluated on one cohort. RESULTS: All tests showed invariably 100% specificity. Sensitivity was 68.9% (95% CI: 55.7–80; SGTI-Flex), 71.1% (95% CI: 55.6–83.6; Panbio), and 84.6% (95% CI: 72–93.1; NovaGen) in clinically suspected patients and 84.6% (95% CI: 54.5–98.1), 33.3% (95% CI: 11.8–61.6), and 55.6% (95% CI: 30.7–78.4) in close asymptomatic contacts, respectively. Sensitivity was systematically higher in samples yielding positive PCR results with Ct ≤ 20. DISCUSSION: We found considerable test-to-test antigen detection variations among patients with clinical suspicion of COVID-19 and close asymptomatic contacts. Negative antigen results, regardless of the test used, should be confirmed by PCR.
format Online
Article
Text
id pubmed-8858772
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd.
record_format MEDLINE/PubMed
spelling pubmed-88587722022-02-22 Different performance of three point-of-care SARS-CoV-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study Escribano, Pilar Sánchez-Pulido, Ana-Erika González-Leiva, José Valero-López, Iván Catalán, Pilar Muñoz, Patricia Guinea, Jesús Clin Microbiol Infect Original Article OBJECTIVES: PCR on nasopharyngeal exudates, the cornerstone of the detection of SARS-CoV-2, is time-consuming and commonly unavailable at primary health care centres. Detection of viral nucleocapsid antigens using lateral flow point-of-care tests is helpful for the early triage of patients who attend health care facilities. METHODS: This was a prospective study carried out in clinically suspected cases and close asymptomatic contacts who attended a primary care centre (Madrid, Spain) for SARS-CoV-2 detection. Patients were divided into three 300-patient cohorts (n = 200 symptomatic cases and n = 100 close asymptomatic contacts per cohort). Three antigen detection tests (SGTI-Flex COVID-19 Ag, Panbio COVID-19 Ag Rapid Test Device, and GSD NovaGen SARS-CoV-2 Ag Rapid Test) were used and compared. Paired nasopharyngeal exudates were obtained, one swab for PCR and the other for antigen detection. Each antigen detection test was evaluated on one cohort. RESULTS: All tests showed invariably 100% specificity. Sensitivity was 68.9% (95% CI: 55.7–80; SGTI-Flex), 71.1% (95% CI: 55.6–83.6; Panbio), and 84.6% (95% CI: 72–93.1; NovaGen) in clinically suspected patients and 84.6% (95% CI: 54.5–98.1), 33.3% (95% CI: 11.8–61.6), and 55.6% (95% CI: 30.7–78.4) in close asymptomatic contacts, respectively. Sensitivity was systematically higher in samples yielding positive PCR results with Ct ≤ 20. DISCUSSION: We found considerable test-to-test antigen detection variations among patients with clinical suspicion of COVID-19 and close asymptomatic contacts. Negative antigen results, regardless of the test used, should be confirmed by PCR. European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. 2022-06 2022-02-21 /pmc/articles/PMC8858772/ /pubmed/35202788 http://dx.doi.org/10.1016/j.cmi.2022.02.014 Text en © 2022 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Original Article
Escribano, Pilar
Sánchez-Pulido, Ana-Erika
González-Leiva, José
Valero-López, Iván
Catalán, Pilar
Muñoz, Patricia
Guinea, Jesús
Different performance of three point-of-care SARS-CoV-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study
title Different performance of three point-of-care SARS-CoV-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study
title_full Different performance of three point-of-care SARS-CoV-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study
title_fullStr Different performance of three point-of-care SARS-CoV-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study
title_full_unstemmed Different performance of three point-of-care SARS-CoV-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study
title_short Different performance of three point-of-care SARS-CoV-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study
title_sort different performance of three point-of-care sars-cov-2 antigen detection devices in symptomatic patients and close asymptomatic contacts: a real-life study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8858772/
https://www.ncbi.nlm.nih.gov/pubmed/35202788
http://dx.doi.org/10.1016/j.cmi.2022.02.014
work_keys_str_mv AT escribanopilar differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy
AT sanchezpulidoanaerika differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy
AT gonzalezleivajose differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy
AT valerolopezivan differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy
AT catalanpilar differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy
AT munozpatricia differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy
AT guineajesus differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy
AT differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy
AT differentperformanceofthreepointofcaresarscov2antigendetectiondevicesinsymptomaticpatientsandcloseasymptomaticcontactsareallifestudy