Cargando…

Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study

BACKGROUND: The purpose of this study was to evaluate the clinical and radiologic outcomes of reverse total shoulder arthroplasty (RTSA) using a small glenoid baseplate in patients with a small glenoid and to analyze the contributing factors to scapular notching. METHODS: A total of 71 RTSAs perform...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Min-Su, Rhee, Yong Girl, Oh, Joo Han, Yoo, Jae Chul, Noh, Kyu-Cheol, Shin, Sang-Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Orthopaedic Association 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8858908/
https://www.ncbi.nlm.nih.gov/pubmed/35251549
http://dx.doi.org/10.4055/cios20301
_version_ 1784654334507614208
author Kim, Min-Su
Rhee, Yong Girl
Oh, Joo Han
Yoo, Jae Chul
Noh, Kyu-Cheol
Shin, Sang-Jin
author_facet Kim, Min-Su
Rhee, Yong Girl
Oh, Joo Han
Yoo, Jae Chul
Noh, Kyu-Cheol
Shin, Sang-Jin
author_sort Kim, Min-Su
collection PubMed
description BACKGROUND: The purpose of this study was to evaluate the clinical and radiologic outcomes of reverse total shoulder arthroplasty (RTSA) using a small glenoid baseplate in patients with a small glenoid and to analyze the contributing factors to scapular notching. METHODS: A total of 71 RTSAs performed using a 25-mm baseplate were evaluated at a mean of 37.0 ± 3.3 months. Shoulder function was evaluated using American Shoulder and Elbow Surgeons (ASES) score, visual analog scale (VAS) for pain, Single Assessment Numeric Evaluation (SANE) for satisfaction, and active range of motion. Scapular neck angle (SNA), prosthesis-scapular neck angle (PSNA), peg glenoid rim distance (PGRD), and sphere bone overhang distance (SBOD) were measured to assess the effects on scapular notching. RESULTS: Shoulder function (ASES: 39.4 ± 13.8 preoperative vs. 76.2 ± 9.5 at last follow-up, p < 0.001), VAS for pain (6.1 ± 1.8 vs. 1.7 ± 1.4, p < 0.001), SANE for satisfaction (7.0 ± 11.8 vs. 83.4 ± 15.3, p < 0.001), and active forward flexion (115.6° ± 40.1° vs. 141.6° ± 17.2°, p < 0.001) were significantly improved. The mean diameter of the inferior glenoid circle was 26.0 ± 3.0 mm and the mean glenoid vault depth was 24.0 ± 4.5 mm. Scapular notching was found in 13 patients (18.3%) and acromial fracture in 2 patients (2.8%). There were no significant differences in preoperative SNA and PSNA at postoperative 3 years between patients with and without scapular notching (101.6° ± 10.5° and 110.8° ± 14.9° vs. 97.3° ± 13.3° and 104.9° ± 12.4°; p = 0.274 and p = 0.142, respectively). PGRD and SBOD were significantly different between patients with scapular notching and without scapular notching (24.8 ± 1.6 mm and 2.6 ± 0.5 mm vs. 21.9 ± 1.9 mm and 5.8 ± 1.9 mm; p < 0.001 and p < 0.001, respectively). CONCLUSIONS: RTSA using a 25-mm baseplate in a Korean population who had relatively small glenoids demonstrated low complication rates and significantly improved clinical outcomes. Scapular notching can be prevented by proper positioning of the baseplate and glenosphere overhang using size-matched glenoid baseplates.
format Online
Article
Text
id pubmed-8858908
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Korean Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-88589082022-03-03 Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study Kim, Min-Su Rhee, Yong Girl Oh, Joo Han Yoo, Jae Chul Noh, Kyu-Cheol Shin, Sang-Jin Clin Orthop Surg Original Article BACKGROUND: The purpose of this study was to evaluate the clinical and radiologic outcomes of reverse total shoulder arthroplasty (RTSA) using a small glenoid baseplate in patients with a small glenoid and to analyze the contributing factors to scapular notching. METHODS: A total of 71 RTSAs performed using a 25-mm baseplate were evaluated at a mean of 37.0 ± 3.3 months. Shoulder function was evaluated using American Shoulder and Elbow Surgeons (ASES) score, visual analog scale (VAS) for pain, Single Assessment Numeric Evaluation (SANE) for satisfaction, and active range of motion. Scapular neck angle (SNA), prosthesis-scapular neck angle (PSNA), peg glenoid rim distance (PGRD), and sphere bone overhang distance (SBOD) were measured to assess the effects on scapular notching. RESULTS: Shoulder function (ASES: 39.4 ± 13.8 preoperative vs. 76.2 ± 9.5 at last follow-up, p < 0.001), VAS for pain (6.1 ± 1.8 vs. 1.7 ± 1.4, p < 0.001), SANE for satisfaction (7.0 ± 11.8 vs. 83.4 ± 15.3, p < 0.001), and active forward flexion (115.6° ± 40.1° vs. 141.6° ± 17.2°, p < 0.001) were significantly improved. The mean diameter of the inferior glenoid circle was 26.0 ± 3.0 mm and the mean glenoid vault depth was 24.0 ± 4.5 mm. Scapular notching was found in 13 patients (18.3%) and acromial fracture in 2 patients (2.8%). There were no significant differences in preoperative SNA and PSNA at postoperative 3 years between patients with and without scapular notching (101.6° ± 10.5° and 110.8° ± 14.9° vs. 97.3° ± 13.3° and 104.9° ± 12.4°; p = 0.274 and p = 0.142, respectively). PGRD and SBOD were significantly different between patients with scapular notching and without scapular notching (24.8 ± 1.6 mm and 2.6 ± 0.5 mm vs. 21.9 ± 1.9 mm and 5.8 ± 1.9 mm; p < 0.001 and p < 0.001, respectively). CONCLUSIONS: RTSA using a 25-mm baseplate in a Korean population who had relatively small glenoids demonstrated low complication rates and significantly improved clinical outcomes. Scapular notching can be prevented by proper positioning of the baseplate and glenosphere overhang using size-matched glenoid baseplates. The Korean Orthopaedic Association 2022-03 2022-01-21 /pmc/articles/PMC8858908/ /pubmed/35251549 http://dx.doi.org/10.4055/cios20301 Text en Copyright © 2022 by The Korean Orthopaedic Association https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Min-Su
Rhee, Yong Girl
Oh, Joo Han
Yoo, Jae Chul
Noh, Kyu-Cheol
Shin, Sang-Jin
Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study
title Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study
title_full Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study
title_fullStr Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study
title_full_unstemmed Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study
title_short Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study
title_sort clinical and radiologic outcomes of small glenoid baseplate in reverse total shoulder arthroplasty: a prospective multicenter study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8858908/
https://www.ncbi.nlm.nih.gov/pubmed/35251549
http://dx.doi.org/10.4055/cios20301
work_keys_str_mv AT kimminsu clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy
AT rheeyonggirl clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy
AT ohjoohan clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy
AT yoojaechul clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy
AT nohkyucheol clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy
AT shinsangjin clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy