Cargando…
Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study
BACKGROUND: The purpose of this study was to evaluate the clinical and radiologic outcomes of reverse total shoulder arthroplasty (RTSA) using a small glenoid baseplate in patients with a small glenoid and to analyze the contributing factors to scapular notching. METHODS: A total of 71 RTSAs perform...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Orthopaedic Association
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8858908/ https://www.ncbi.nlm.nih.gov/pubmed/35251549 http://dx.doi.org/10.4055/cios20301 |
_version_ | 1784654334507614208 |
---|---|
author | Kim, Min-Su Rhee, Yong Girl Oh, Joo Han Yoo, Jae Chul Noh, Kyu-Cheol Shin, Sang-Jin |
author_facet | Kim, Min-Su Rhee, Yong Girl Oh, Joo Han Yoo, Jae Chul Noh, Kyu-Cheol Shin, Sang-Jin |
author_sort | Kim, Min-Su |
collection | PubMed |
description | BACKGROUND: The purpose of this study was to evaluate the clinical and radiologic outcomes of reverse total shoulder arthroplasty (RTSA) using a small glenoid baseplate in patients with a small glenoid and to analyze the contributing factors to scapular notching. METHODS: A total of 71 RTSAs performed using a 25-mm baseplate were evaluated at a mean of 37.0 ± 3.3 months. Shoulder function was evaluated using American Shoulder and Elbow Surgeons (ASES) score, visual analog scale (VAS) for pain, Single Assessment Numeric Evaluation (SANE) for satisfaction, and active range of motion. Scapular neck angle (SNA), prosthesis-scapular neck angle (PSNA), peg glenoid rim distance (PGRD), and sphere bone overhang distance (SBOD) were measured to assess the effects on scapular notching. RESULTS: Shoulder function (ASES: 39.4 ± 13.8 preoperative vs. 76.2 ± 9.5 at last follow-up, p < 0.001), VAS for pain (6.1 ± 1.8 vs. 1.7 ± 1.4, p < 0.001), SANE for satisfaction (7.0 ± 11.8 vs. 83.4 ± 15.3, p < 0.001), and active forward flexion (115.6° ± 40.1° vs. 141.6° ± 17.2°, p < 0.001) were significantly improved. The mean diameter of the inferior glenoid circle was 26.0 ± 3.0 mm and the mean glenoid vault depth was 24.0 ± 4.5 mm. Scapular notching was found in 13 patients (18.3%) and acromial fracture in 2 patients (2.8%). There were no significant differences in preoperative SNA and PSNA at postoperative 3 years between patients with and without scapular notching (101.6° ± 10.5° and 110.8° ± 14.9° vs. 97.3° ± 13.3° and 104.9° ± 12.4°; p = 0.274 and p = 0.142, respectively). PGRD and SBOD were significantly different between patients with scapular notching and without scapular notching (24.8 ± 1.6 mm and 2.6 ± 0.5 mm vs. 21.9 ± 1.9 mm and 5.8 ± 1.9 mm; p < 0.001 and p < 0.001, respectively). CONCLUSIONS: RTSA using a 25-mm baseplate in a Korean population who had relatively small glenoids demonstrated low complication rates and significantly improved clinical outcomes. Scapular notching can be prevented by proper positioning of the baseplate and glenosphere overhang using size-matched glenoid baseplates. |
format | Online Article Text |
id | pubmed-8858908 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Korean Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-88589082022-03-03 Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study Kim, Min-Su Rhee, Yong Girl Oh, Joo Han Yoo, Jae Chul Noh, Kyu-Cheol Shin, Sang-Jin Clin Orthop Surg Original Article BACKGROUND: The purpose of this study was to evaluate the clinical and radiologic outcomes of reverse total shoulder arthroplasty (RTSA) using a small glenoid baseplate in patients with a small glenoid and to analyze the contributing factors to scapular notching. METHODS: A total of 71 RTSAs performed using a 25-mm baseplate were evaluated at a mean of 37.0 ± 3.3 months. Shoulder function was evaluated using American Shoulder and Elbow Surgeons (ASES) score, visual analog scale (VAS) for pain, Single Assessment Numeric Evaluation (SANE) for satisfaction, and active range of motion. Scapular neck angle (SNA), prosthesis-scapular neck angle (PSNA), peg glenoid rim distance (PGRD), and sphere bone overhang distance (SBOD) were measured to assess the effects on scapular notching. RESULTS: Shoulder function (ASES: 39.4 ± 13.8 preoperative vs. 76.2 ± 9.5 at last follow-up, p < 0.001), VAS for pain (6.1 ± 1.8 vs. 1.7 ± 1.4, p < 0.001), SANE for satisfaction (7.0 ± 11.8 vs. 83.4 ± 15.3, p < 0.001), and active forward flexion (115.6° ± 40.1° vs. 141.6° ± 17.2°, p < 0.001) were significantly improved. The mean diameter of the inferior glenoid circle was 26.0 ± 3.0 mm and the mean glenoid vault depth was 24.0 ± 4.5 mm. Scapular notching was found in 13 patients (18.3%) and acromial fracture in 2 patients (2.8%). There were no significant differences in preoperative SNA and PSNA at postoperative 3 years between patients with and without scapular notching (101.6° ± 10.5° and 110.8° ± 14.9° vs. 97.3° ± 13.3° and 104.9° ± 12.4°; p = 0.274 and p = 0.142, respectively). PGRD and SBOD were significantly different between patients with scapular notching and without scapular notching (24.8 ± 1.6 mm and 2.6 ± 0.5 mm vs. 21.9 ± 1.9 mm and 5.8 ± 1.9 mm; p < 0.001 and p < 0.001, respectively). CONCLUSIONS: RTSA using a 25-mm baseplate in a Korean population who had relatively small glenoids demonstrated low complication rates and significantly improved clinical outcomes. Scapular notching can be prevented by proper positioning of the baseplate and glenosphere overhang using size-matched glenoid baseplates. The Korean Orthopaedic Association 2022-03 2022-01-21 /pmc/articles/PMC8858908/ /pubmed/35251549 http://dx.doi.org/10.4055/cios20301 Text en Copyright © 2022 by The Korean Orthopaedic Association https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Min-Su Rhee, Yong Girl Oh, Joo Han Yoo, Jae Chul Noh, Kyu-Cheol Shin, Sang-Jin Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study |
title | Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study |
title_full | Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study |
title_fullStr | Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study |
title_full_unstemmed | Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study |
title_short | Clinical and Radiologic Outcomes of Small Glenoid Baseplate in Reverse Total Shoulder Arthroplasty: A Prospective Multicenter Study |
title_sort | clinical and radiologic outcomes of small glenoid baseplate in reverse total shoulder arthroplasty: a prospective multicenter study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8858908/ https://www.ncbi.nlm.nih.gov/pubmed/35251549 http://dx.doi.org/10.4055/cios20301 |
work_keys_str_mv | AT kimminsu clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy AT rheeyonggirl clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy AT ohjoohan clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy AT yoojaechul clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy AT nohkyucheol clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy AT shinsangjin clinicalandradiologicoutcomesofsmallglenoidbaseplateinreversetotalshoulderarthroplastyaprospectivemulticenterstudy |