Cargando…

Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities

The data in this paper are related to the research article entitled “Load applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art prosthetic components” (Frossard et al. Clinical Biomechanics, 89 (2021) 105457. DOI: 10.1016/j.clinbiomech.2021.105457)....

Descripción completa

Detalles Bibliográficos
Autores principales: Frossard, Laurent, Laux, Stefan, Geada, Marta, Heym, Peter Paul, Lechler, Knut
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859002/
https://www.ncbi.nlm.nih.gov/pubmed/35242918
http://dx.doi.org/10.1016/j.dib.2022.107936
_version_ 1784654357019492352
author Frossard, Laurent
Laux, Stefan
Geada, Marta
Heym, Peter Paul
Lechler, Knut
author_facet Frossard, Laurent
Laux, Stefan
Geada, Marta
Heym, Peter Paul
Lechler, Knut
author_sort Frossard, Laurent
collection PubMed
description The data in this paper are related to the research article entitled “Load applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art prosthetic components” (Frossard et al. Clinical Biomechanics, 89 (2021) 105457. DOI: 10.1016/j.clinbiomech.2021.105457). This article contains the overall and individual loading characteristics applied on transfemoral press-fit osseointegrated implant generated by bone-anchored prostheses fitted with state-of-the-art components during daily activities (i.e., microprocessor-controlled Rheo Knee XC knee, energy-storing-and-returning Pro-Flex XC or LP feet (ÖSSUR, Iceland)). Confounders of the loads are presented. The load profiles are characterized by the loading patterns, loading boundaries and loading local extrema of the forces and moments applied during straight-level walking, ascending and descending ramp and stairs at self-selected comfortable pace. The confounders of the loading information as well as new insights into inter-participants variability of loading patterns, loading boundaries and loading local extrema can inform the design of subsequent cross-sectional and longitudinal studies as well as literature reviews and meta-analyzes. The loading datasets are critical to clinicians and engineers designing finite element models of osseointegrated implants (e.g., medullar and percutaneous parts) and prosthetic components, algorithms capable to recognize the loading patterns applied on a residuum during daily activities, as well as clinical trials assessing the effects of particular prosthetic care interventions. Altogether, these datasets provide promoters of prosthetic care innovations with valuable insights informing the prescription of advanced prosthetic components to the growing population of individuals suffering from lower limb loss choosing bionics solutions. Online repository contains the files: https://data.mendeley.com/datasets/gmsyv97cpc/1
format Online
Article
Text
id pubmed-8859002
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-88590022022-03-02 Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities Frossard, Laurent Laux, Stefan Geada, Marta Heym, Peter Paul Lechler, Knut Data Brief Data Article The data in this paper are related to the research article entitled “Load applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art prosthetic components” (Frossard et al. Clinical Biomechanics, 89 (2021) 105457. DOI: 10.1016/j.clinbiomech.2021.105457). This article contains the overall and individual loading characteristics applied on transfemoral press-fit osseointegrated implant generated by bone-anchored prostheses fitted with state-of-the-art components during daily activities (i.e., microprocessor-controlled Rheo Knee XC knee, energy-storing-and-returning Pro-Flex XC or LP feet (ÖSSUR, Iceland)). Confounders of the loads are presented. The load profiles are characterized by the loading patterns, loading boundaries and loading local extrema of the forces and moments applied during straight-level walking, ascending and descending ramp and stairs at self-selected comfortable pace. The confounders of the loading information as well as new insights into inter-participants variability of loading patterns, loading boundaries and loading local extrema can inform the design of subsequent cross-sectional and longitudinal studies as well as literature reviews and meta-analyzes. The loading datasets are critical to clinicians and engineers designing finite element models of osseointegrated implants (e.g., medullar and percutaneous parts) and prosthetic components, algorithms capable to recognize the loading patterns applied on a residuum during daily activities, as well as clinical trials assessing the effects of particular prosthetic care interventions. Altogether, these datasets provide promoters of prosthetic care innovations with valuable insights informing the prescription of advanced prosthetic components to the growing population of individuals suffering from lower limb loss choosing bionics solutions. Online repository contains the files: https://data.mendeley.com/datasets/gmsyv97cpc/1 Elsevier 2022-02-10 /pmc/articles/PMC8859002/ /pubmed/35242918 http://dx.doi.org/10.1016/j.dib.2022.107936 Text en © 2022 The Author(s). Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Data Article
Frossard, Laurent
Laux, Stefan
Geada, Marta
Heym, Peter Paul
Lechler, Knut
Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
title Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
title_full Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
title_fullStr Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
title_full_unstemmed Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
title_short Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
title_sort loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859002/
https://www.ncbi.nlm.nih.gov/pubmed/35242918
http://dx.doi.org/10.1016/j.dib.2022.107936
work_keys_str_mv AT frossardlaurent loadingcharacteristicsdataappliedonosseointegratedimplantbytransfemoralboneanchoredprosthesesfittedwithstateoftheartcomponentsduringdailyactivities
AT lauxstefan loadingcharacteristicsdataappliedonosseointegratedimplantbytransfemoralboneanchoredprosthesesfittedwithstateoftheartcomponentsduringdailyactivities
AT geadamarta loadingcharacteristicsdataappliedonosseointegratedimplantbytransfemoralboneanchoredprosthesesfittedwithstateoftheartcomponentsduringdailyactivities
AT heympeterpaul loadingcharacteristicsdataappliedonosseointegratedimplantbytransfemoralboneanchoredprosthesesfittedwithstateoftheartcomponentsduringdailyactivities
AT lechlerknut loadingcharacteristicsdataappliedonosseointegratedimplantbytransfemoralboneanchoredprosthesesfittedwithstateoftheartcomponentsduringdailyactivities