Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China
BACKGROUND: Accurate measurements of serum insulin and C-peptide are needed for the therapy and classification of diabetes. This study investigated the status of serum insulin and C-peptide measurements in China by analyzing the results of five pooled serum samples measured in 94 laboratories. METHO...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society for Laboratory Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859554/ https://www.ncbi.nlm.nih.gov/pubmed/35177563 http://dx.doi.org/10.3343/alm.2022.42.4.428 |
_version_ | 1784654486970564608 |
---|---|
author | Zhou, Weiyan Deng, Yuhang Zhao, Haijian Zhang, Chuanbao |
author_facet | Zhou, Weiyan Deng, Yuhang Zhao, Haijian Zhang, Chuanbao |
author_sort | Zhou, Weiyan |
collection | PubMed |
description | BACKGROUND: Accurate measurements of serum insulin and C-peptide are needed for the therapy and classification of diabetes. This study investigated the status of serum insulin and C-peptide measurements in China by analyzing the results of five pooled serum samples measured in 94 laboratories. METHODS: Patient serum samples were pooled into five groups according to insulin and C-peptide concentrations and measured in 94 laboratories using different measurement systems. The inter- and intra-laboratory %CV as well as inter- and intra-measurement system %CV were calculated to assess the status of insulin and C-peptide measurements. To verify whether the disagreement between laboratories was due to different calibrators, as reported in previous studies, one low-level and one high-level sample extracted from the five pooled serum samples were used to recalibrate clinical measurement systems. RESULTS: The mean intra-laboratory, intra-measurement system, inter-laboratory, and inter-measurement system %CVs were 2.7%, 4.8%, 21.8%, and 22.4%, respectively, for insulin and 2.3%, 6.7%, 16.4%, and 24.5%, respectively, for C-peptide. The inter- and intra-laboratory %CVs for insulin decreased with increasing concentration. After recalibration with low- and high-level samples, the mean inter-measurement %CV decreased from 22.4% to 17.2% for insulin and from 24.5% to 5.7% for C-peptide. CONCLUSIONS: The intra-laboratory and intra-measurement system imprecision values are satisfactory for serum insulin and C-peptide measurements. However, the results from laboratories using different measurement systems were not comparable, and there is still much work needed to achieve the standardization or harmonization of serum insulin and C-peptide measurements. |
format | Online Article Text |
id | pubmed-8859554 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-88595542022-07-01 Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China Zhou, Weiyan Deng, Yuhang Zhao, Haijian Zhang, Chuanbao Ann Lab Med Original Article BACKGROUND: Accurate measurements of serum insulin and C-peptide are needed for the therapy and classification of diabetes. This study investigated the status of serum insulin and C-peptide measurements in China by analyzing the results of five pooled serum samples measured in 94 laboratories. METHODS: Patient serum samples were pooled into five groups according to insulin and C-peptide concentrations and measured in 94 laboratories using different measurement systems. The inter- and intra-laboratory %CV as well as inter- and intra-measurement system %CV were calculated to assess the status of insulin and C-peptide measurements. To verify whether the disagreement between laboratories was due to different calibrators, as reported in previous studies, one low-level and one high-level sample extracted from the five pooled serum samples were used to recalibrate clinical measurement systems. RESULTS: The mean intra-laboratory, intra-measurement system, inter-laboratory, and inter-measurement system %CVs were 2.7%, 4.8%, 21.8%, and 22.4%, respectively, for insulin and 2.3%, 6.7%, 16.4%, and 24.5%, respectively, for C-peptide. The inter- and intra-laboratory %CVs for insulin decreased with increasing concentration. After recalibration with low- and high-level samples, the mean inter-measurement %CV decreased from 22.4% to 17.2% for insulin and from 24.5% to 5.7% for C-peptide. CONCLUSIONS: The intra-laboratory and intra-measurement system imprecision values are satisfactory for serum insulin and C-peptide measurements. However, the results from laboratories using different measurement systems were not comparable, and there is still much work needed to achieve the standardization or harmonization of serum insulin and C-peptide measurements. Korean Society for Laboratory Medicine 2022-07-01 2022-07-01 /pmc/articles/PMC8859554/ /pubmed/35177563 http://dx.doi.org/10.3343/alm.2022.42.4.428 Text en © Korean Society for Laboratory Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Zhou, Weiyan Deng, Yuhang Zhao, Haijian Zhang, Chuanbao Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China |
title | Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China |
title_full | Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China |
title_fullStr | Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China |
title_full_unstemmed | Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China |
title_short | Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China |
title_sort | current status of serum insulin and c-peptide measurement in clinical laboratories: experience from 94 laboratories in china |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859554/ https://www.ncbi.nlm.nih.gov/pubmed/35177563 http://dx.doi.org/10.3343/alm.2022.42.4.428 |
work_keys_str_mv | AT zhouweiyan currentstatusofseruminsulinandcpeptidemeasurementinclinicallaboratoriesexperiencefrom94laboratoriesinchina AT dengyuhang currentstatusofseruminsulinandcpeptidemeasurementinclinicallaboratoriesexperiencefrom94laboratoriesinchina AT zhaohaijian currentstatusofseruminsulinandcpeptidemeasurementinclinicallaboratoriesexperiencefrom94laboratoriesinchina AT zhangchuanbao currentstatusofseruminsulinandcpeptidemeasurementinclinicallaboratoriesexperiencefrom94laboratoriesinchina |