Cargando…

Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time

BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral...

Descripción completa

Detalles Bibliográficos
Autores principales: Nam, Minjeong, Yoon, Sumi, Hur, Mina, Lee, Gun Hyuk, Kim, Hanah, Park, Mikyoung, Kim, Hyeong Nyeon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society for Laboratory Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859564/
https://www.ncbi.nlm.nih.gov/pubmed/35177560
http://dx.doi.org/10.3343/alm.2022.42.4.398
_version_ 1784654489441009664
author Nam, Minjeong
Yoon, Sumi
Hur, Mina
Lee, Gun Hyuk
Kim, Hanah
Park, Mikyoung
Kim, Hyeong Nyeon
author_facet Nam, Minjeong
Yoon, Sumi
Hur, Mina
Lee, Gun Hyuk
Kim, Hanah
Park, Mikyoung
Kim, Hyeong Nyeon
author_sort Nam, Minjeong
collection PubMed
description BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral blood smear samples were divided into normal, mild leukopenia, moderate leukopenia, and severe leukopenia groups based on WBC count. In each group, the risk and turnaround time (TAT) were compared between DI-60 and manual counting. Risk was determined by failure mode and effect analysis using the risk priority number (RPN) score, and TAT was recorded for the analytical phase. RESULTS: Overall, DI-60 showed a five-fold lower risk (70 vs. 350 RPN) and longer TAT than manual counting. In severe leukopenic samples, DI-60 showed a shorter TAT/slide and a remarkably lower cell count/slide than manual counting. In all samples, the TAT/cell for DI-60 was substantially longer than that for manual counting (DI-60 vs. manual total, 1.8 vs. 1.0 sec; normal, 1.5 vs. 0.7 sec; mild leukopenia, 1.9 vs. 0.9 sec; moderate leukopenia, 1.8 vs. 1.0 sec; severe leukopenia, 28.8 vs. 19.0 sec). CONCLUSIONS: This is the first comparative assessment of risk and TAT between DI-60 and manual counting in leukopenic samples. DI-60 decreases the laboratory risk and improves patient safety, but requires more time to count fewer cells, especially in severe leukopenic samples. DM analyzers should be applied selectively depending on the WBC count to optimize laboratory efficiency.
format Online
Article
Text
id pubmed-8859564
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-88595642022-07-01 Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time Nam, Minjeong Yoon, Sumi Hur, Mina Lee, Gun Hyuk Kim, Hanah Park, Mikyoung Kim, Hyeong Nyeon Ann Lab Med Original Article BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral blood smear samples were divided into normal, mild leukopenia, moderate leukopenia, and severe leukopenia groups based on WBC count. In each group, the risk and turnaround time (TAT) were compared between DI-60 and manual counting. Risk was determined by failure mode and effect analysis using the risk priority number (RPN) score, and TAT was recorded for the analytical phase. RESULTS: Overall, DI-60 showed a five-fold lower risk (70 vs. 350 RPN) and longer TAT than manual counting. In severe leukopenic samples, DI-60 showed a shorter TAT/slide and a remarkably lower cell count/slide than manual counting. In all samples, the TAT/cell for DI-60 was substantially longer than that for manual counting (DI-60 vs. manual total, 1.8 vs. 1.0 sec; normal, 1.5 vs. 0.7 sec; mild leukopenia, 1.9 vs. 0.9 sec; moderate leukopenia, 1.8 vs. 1.0 sec; severe leukopenia, 28.8 vs. 19.0 sec). CONCLUSIONS: This is the first comparative assessment of risk and TAT between DI-60 and manual counting in leukopenic samples. DI-60 decreases the laboratory risk and improves patient safety, but requires more time to count fewer cells, especially in severe leukopenic samples. DM analyzers should be applied selectively depending on the WBC count to optimize laboratory efficiency. Korean Society for Laboratory Medicine 2022-07-01 2022-07-01 /pmc/articles/PMC8859564/ /pubmed/35177560 http://dx.doi.org/10.3343/alm.2022.42.4.398 Text en © Korean Society for Laboratory Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Nam, Minjeong
Yoon, Sumi
Hur, Mina
Lee, Gun Hyuk
Kim, Hanah
Park, Mikyoung
Kim, Hyeong Nyeon
Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time
title Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time
title_full Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time
title_fullStr Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time
title_full_unstemmed Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time
title_short Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time
title_sort digital morphology analyzer sysmex di-60 vs. manual counting for white blood cell differentials in leukopenic samples: a comparative assessment of risk and turnaround time
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859564/
https://www.ncbi.nlm.nih.gov/pubmed/35177560
http://dx.doi.org/10.3343/alm.2022.42.4.398
work_keys_str_mv AT namminjeong digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime
AT yoonsumi digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime
AT hurmina digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime
AT leegunhyuk digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime
AT kimhanah digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime
AT parkmikyoung digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime
AT kimhyeongnyeon digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime