Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time
BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society for Laboratory Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859564/ https://www.ncbi.nlm.nih.gov/pubmed/35177560 http://dx.doi.org/10.3343/alm.2022.42.4.398 |
_version_ | 1784654489441009664 |
---|---|
author | Nam, Minjeong Yoon, Sumi Hur, Mina Lee, Gun Hyuk Kim, Hanah Park, Mikyoung Kim, Hyeong Nyeon |
author_facet | Nam, Minjeong Yoon, Sumi Hur, Mina Lee, Gun Hyuk Kim, Hanah Park, Mikyoung Kim, Hyeong Nyeon |
author_sort | Nam, Minjeong |
collection | PubMed |
description | BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral blood smear samples were divided into normal, mild leukopenia, moderate leukopenia, and severe leukopenia groups based on WBC count. In each group, the risk and turnaround time (TAT) were compared between DI-60 and manual counting. Risk was determined by failure mode and effect analysis using the risk priority number (RPN) score, and TAT was recorded for the analytical phase. RESULTS: Overall, DI-60 showed a five-fold lower risk (70 vs. 350 RPN) and longer TAT than manual counting. In severe leukopenic samples, DI-60 showed a shorter TAT/slide and a remarkably lower cell count/slide than manual counting. In all samples, the TAT/cell for DI-60 was substantially longer than that for manual counting (DI-60 vs. manual total, 1.8 vs. 1.0 sec; normal, 1.5 vs. 0.7 sec; mild leukopenia, 1.9 vs. 0.9 sec; moderate leukopenia, 1.8 vs. 1.0 sec; severe leukopenia, 28.8 vs. 19.0 sec). CONCLUSIONS: This is the first comparative assessment of risk and TAT between DI-60 and manual counting in leukopenic samples. DI-60 decreases the laboratory risk and improves patient safety, but requires more time to count fewer cells, especially in severe leukopenic samples. DM analyzers should be applied selectively depending on the WBC count to optimize laboratory efficiency. |
format | Online Article Text |
id | pubmed-8859564 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-88595642022-07-01 Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time Nam, Minjeong Yoon, Sumi Hur, Mina Lee, Gun Hyuk Kim, Hanah Park, Mikyoung Kim, Hyeong Nyeon Ann Lab Med Original Article BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral blood smear samples were divided into normal, mild leukopenia, moderate leukopenia, and severe leukopenia groups based on WBC count. In each group, the risk and turnaround time (TAT) were compared between DI-60 and manual counting. Risk was determined by failure mode and effect analysis using the risk priority number (RPN) score, and TAT was recorded for the analytical phase. RESULTS: Overall, DI-60 showed a five-fold lower risk (70 vs. 350 RPN) and longer TAT than manual counting. In severe leukopenic samples, DI-60 showed a shorter TAT/slide and a remarkably lower cell count/slide than manual counting. In all samples, the TAT/cell for DI-60 was substantially longer than that for manual counting (DI-60 vs. manual total, 1.8 vs. 1.0 sec; normal, 1.5 vs. 0.7 sec; mild leukopenia, 1.9 vs. 0.9 sec; moderate leukopenia, 1.8 vs. 1.0 sec; severe leukopenia, 28.8 vs. 19.0 sec). CONCLUSIONS: This is the first comparative assessment of risk and TAT between DI-60 and manual counting in leukopenic samples. DI-60 decreases the laboratory risk and improves patient safety, but requires more time to count fewer cells, especially in severe leukopenic samples. DM analyzers should be applied selectively depending on the WBC count to optimize laboratory efficiency. Korean Society for Laboratory Medicine 2022-07-01 2022-07-01 /pmc/articles/PMC8859564/ /pubmed/35177560 http://dx.doi.org/10.3343/alm.2022.42.4.398 Text en © Korean Society for Laboratory Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Nam, Minjeong Yoon, Sumi Hur, Mina Lee, Gun Hyuk Kim, Hanah Park, Mikyoung Kim, Hyeong Nyeon Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time |
title | Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time |
title_full | Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time |
title_fullStr | Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time |
title_full_unstemmed | Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time |
title_short | Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time |
title_sort | digital morphology analyzer sysmex di-60 vs. manual counting for white blood cell differentials in leukopenic samples: a comparative assessment of risk and turnaround time |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859564/ https://www.ncbi.nlm.nih.gov/pubmed/35177560 http://dx.doi.org/10.3343/alm.2022.42.4.398 |
work_keys_str_mv | AT namminjeong digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime AT yoonsumi digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime AT hurmina digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime AT leegunhyuk digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime AT kimhanah digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime AT parkmikyoung digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime AT kimhyeongnyeon digitalmorphologyanalyzersysmexdi60vsmanualcountingforwhitebloodcelldifferentialsinleukopenicsamplesacomparativeassessmentofriskandturnaroundtime |