Cargando…
Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein
This paper reports on an ultrasensitive and label-free electrochemical immunosensor for monitoring the SARS-CoV-2 spike protein (SARS-CoV-2 SP). A self-supported electrode, which can simultaneously serve as an antibody immobilization matrix and electron transport channel, was initially fabricated by...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860393/ https://www.ncbi.nlm.nih.gov/pubmed/35221530 http://dx.doi.org/10.1016/j.snb.2022.131591 |
_version_ | 1784654662680444928 |
---|---|
author | Adeel, Muhammad Asif, Kanwal Canzonieri, Vincenzo Barai, Hasi Rani Rahman, Md. Mahbubur Daniele, Salvatore Rizzolio, Flavio |
author_facet | Adeel, Muhammad Asif, Kanwal Canzonieri, Vincenzo Barai, Hasi Rani Rahman, Md. Mahbubur Daniele, Salvatore Rizzolio, Flavio |
author_sort | Adeel, Muhammad |
collection | PubMed |
description | This paper reports on an ultrasensitive and label-free electrochemical immunosensor for monitoring the SARS-CoV-2 spike protein (SARS-CoV-2 SP). A self-supported electrode, which can simultaneously serve as an antibody immobilization matrix and electron transport channel, was initially fabricated by a controlled partial exfoliation of a flexible graphitic carbon foil (GCF). Mild acidic treatment enabled the partial oxidation and exfoliation (down to a few layers) of the flexible GCF; this also provided a high percentage of oxygen functionality and an enhanced surface roughness. The substrate electrode was further functionalized with ethylenediamine (EDA) to provide a suitable platform with even a higher surface roughness, for the covalent immobilization of an anti-SARS-CoV-2 antibody. The change in the current response for the [Fe(CN)(6)](3−/4−) redox couple, induced by the binding of SARS-CoV-2 SP to the antibody immobilized on the electrode surface, was used to determine the SARS-CoV-2 SP concentration. The immunosensor thus prepared could detect SARS-CoV-2 SP within 30 min with high reproducibility and specificity over a wide concentration range (0.2–100 ng/mL). Detection limits of 25 pg/mL and 27 pg/mL were found in a phosphate buffer solution (pH 7.4), and diluted blood plasma, respectively. The immunosensor was also employed to detect SARS-CoV-2 SP in artificial human saliva. |
format | Online Article Text |
id | pubmed-8860393 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-88603932022-02-22 Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein Adeel, Muhammad Asif, Kanwal Canzonieri, Vincenzo Barai, Hasi Rani Rahman, Md. Mahbubur Daniele, Salvatore Rizzolio, Flavio Sens Actuators B Chem Article This paper reports on an ultrasensitive and label-free electrochemical immunosensor for monitoring the SARS-CoV-2 spike protein (SARS-CoV-2 SP). A self-supported electrode, which can simultaneously serve as an antibody immobilization matrix and electron transport channel, was initially fabricated by a controlled partial exfoliation of a flexible graphitic carbon foil (GCF). Mild acidic treatment enabled the partial oxidation and exfoliation (down to a few layers) of the flexible GCF; this also provided a high percentage of oxygen functionality and an enhanced surface roughness. The substrate electrode was further functionalized with ethylenediamine (EDA) to provide a suitable platform with even a higher surface roughness, for the covalent immobilization of an anti-SARS-CoV-2 antibody. The change in the current response for the [Fe(CN)(6)](3−/4−) redox couple, induced by the binding of SARS-CoV-2 SP to the antibody immobilized on the electrode surface, was used to determine the SARS-CoV-2 SP concentration. The immunosensor thus prepared could detect SARS-CoV-2 SP within 30 min with high reproducibility and specificity over a wide concentration range (0.2–100 ng/mL). Detection limits of 25 pg/mL and 27 pg/mL were found in a phosphate buffer solution (pH 7.4), and diluted blood plasma, respectively. The immunosensor was also employed to detect SARS-CoV-2 SP in artificial human saliva. Elsevier B.V. 2022-05-15 2022-02-21 /pmc/articles/PMC8860393/ /pubmed/35221530 http://dx.doi.org/10.1016/j.snb.2022.131591 Text en © 2022 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Adeel, Muhammad Asif, Kanwal Canzonieri, Vincenzo Barai, Hasi Rani Rahman, Md. Mahbubur Daniele, Salvatore Rizzolio, Flavio Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein |
title | Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein |
title_full | Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein |
title_fullStr | Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein |
title_full_unstemmed | Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein |
title_short | Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein |
title_sort | controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of sars-cov-2 spike protein |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860393/ https://www.ncbi.nlm.nih.gov/pubmed/35221530 http://dx.doi.org/10.1016/j.snb.2022.131591 |
work_keys_str_mv | AT adeelmuhammad controlledpartiallyexfoliatedselfsupportedfunctionalizedflexiblegraphiticcarbonfoilforultrasensitivedetectionofsarscov2spikeprotein AT asifkanwal controlledpartiallyexfoliatedselfsupportedfunctionalizedflexiblegraphiticcarbonfoilforultrasensitivedetectionofsarscov2spikeprotein AT canzonierivincenzo controlledpartiallyexfoliatedselfsupportedfunctionalizedflexiblegraphiticcarbonfoilforultrasensitivedetectionofsarscov2spikeprotein AT baraihasirani controlledpartiallyexfoliatedselfsupportedfunctionalizedflexiblegraphiticcarbonfoilforultrasensitivedetectionofsarscov2spikeprotein AT rahmanmdmahbubur controlledpartiallyexfoliatedselfsupportedfunctionalizedflexiblegraphiticcarbonfoilforultrasensitivedetectionofsarscov2spikeprotein AT danielesalvatore controlledpartiallyexfoliatedselfsupportedfunctionalizedflexiblegraphiticcarbonfoilforultrasensitivedetectionofsarscov2spikeprotein AT rizzolioflavio controlledpartiallyexfoliatedselfsupportedfunctionalizedflexiblegraphiticcarbonfoilforultrasensitivedetectionofsarscov2spikeprotein |