Cargando…
What does an explanted PASCAL device look like?
We report the case of a 78-year-old female patient who had a PASCAL device implanted for severe degenerative mitral regurgitation. Intraprocedural echocardiography revealed persistent severe mitral regurgitation due to device dislocation. Implanting another device was not possible. After 8 days, the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860416/ https://www.ncbi.nlm.nih.gov/pubmed/34792159 http://dx.doi.org/10.1093/icvts/ivab318 |
_version_ | 1784654667632869376 |
---|---|
author | Van Hemelrijck, Mathias Sromicki, Juri Schmiady, Martin O Mestres, Carlos-A |
author_facet | Van Hemelrijck, Mathias Sromicki, Juri Schmiady, Martin O Mestres, Carlos-A |
author_sort | Van Hemelrijck, Mathias |
collection | PubMed |
description | We report the case of a 78-year-old female patient who had a PASCAL device implanted for severe degenerative mitral regurgitation. Intraprocedural echocardiography revealed persistent severe mitral regurgitation due to device dislocation. Implanting another device was not possible. After 8 days, the device was explanted, and the valve was replaced with a biological prosthesis. The PASCAL device and resected mitral valve leaflets were sent for histopathological workup. |
format | Online Article Text |
id | pubmed-8860416 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-88604162022-02-22 What does an explanted PASCAL device look like? Van Hemelrijck, Mathias Sromicki, Juri Schmiady, Martin O Mestres, Carlos-A Interact Cardiovasc Thorac Surg Case Reports We report the case of a 78-year-old female patient who had a PASCAL device implanted for severe degenerative mitral regurgitation. Intraprocedural echocardiography revealed persistent severe mitral regurgitation due to device dislocation. Implanting another device was not possible. After 8 days, the device was explanted, and the valve was replaced with a biological prosthesis. The PASCAL device and resected mitral valve leaflets were sent for histopathological workup. Oxford University Press 2021-11-18 /pmc/articles/PMC8860416/ /pubmed/34792159 http://dx.doi.org/10.1093/icvts/ivab318 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Reports Van Hemelrijck, Mathias Sromicki, Juri Schmiady, Martin O Mestres, Carlos-A What does an explanted PASCAL device look like? |
title | What does an explanted PASCAL device look like? |
title_full | What does an explanted PASCAL device look like? |
title_fullStr | What does an explanted PASCAL device look like? |
title_full_unstemmed | What does an explanted PASCAL device look like? |
title_short | What does an explanted PASCAL device look like? |
title_sort | what does an explanted pascal device look like? |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860416/ https://www.ncbi.nlm.nih.gov/pubmed/34792159 http://dx.doi.org/10.1093/icvts/ivab318 |
work_keys_str_mv | AT vanhemelrijckmathias whatdoesanexplantedpascaldevicelooklike AT sromickijuri whatdoesanexplantedpascaldevicelooklike AT schmiadymartino whatdoesanexplantedpascaldevicelooklike AT mestrescarlosa whatdoesanexplantedpascaldevicelooklike |