Cargando…

Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China

PURPOSE: Abutment access hole on dental implant crowns may facilitate crown retrieval and reduce cement overflow but present esthetic obstacle for patients. This study aimed to investigate the esthetic evaluation and acceptability of implant crowns with different hole designs from the perspective of...

Descripción completa

Detalles Bibliográficos
Autores principales: Wen, Cai, Jiang, Rong, Zhang, Zhiqiang, Lei, Bo, Zhong, Yingquan, Zhou, Huangjun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860758/
https://www.ncbi.nlm.nih.gov/pubmed/35210759
http://dx.doi.org/10.2147/PPA.S351143
_version_ 1784654743703912448
author Wen, Cai
Jiang, Rong
Zhang, Zhiqiang
Lei, Bo
Zhong, Yingquan
Zhou, Huangjun
author_facet Wen, Cai
Jiang, Rong
Zhang, Zhiqiang
Lei, Bo
Zhong, Yingquan
Zhou, Huangjun
author_sort Wen, Cai
collection PubMed
description PURPOSE: Abutment access hole on dental implant crowns may facilitate crown retrieval and reduce cement overflow but present esthetic obstacle for patients. This study aimed to investigate the esthetic evaluation and acceptability of implant crowns with different hole designs from the perspective of patients and dentists. MATERIALS AND METHODS: Anterior and posterior implant zirconia crowns were fabricated into three types: no hole (NH), 1 mm micro hole (MH), and 2.5 mm regular hole (RH). The NH crown was set as the control, and the anterior and posterior crowns with MH and RH were evaluated. The subjects, who were recruited randomly, were comprised of lay patients (n=60) and professional dentists (n=30). All subjects were invited to evaluate the esthetic performance of MH and RH crowns on a Visual Analog Scale (VAS), rate them from 0 to 10, state their acceptability of these crowns, and label them as acceptable and unacceptable. RESULTS: The ANOVA analysis of the VAS esthetic evaluation showed that the size of the hole, the position of the teeth, and the professional background of the subject significantly and independently affected esthetic perception. Crowns with MH in the posterior position had higher esthetic scores and acceptability compared with crowns with RH in the anterior position, and dentists tended to show higher acceptance and better esthetic rating for crowns with holes compared with lay patients. CONCLUSION: The hypothesis that patients and dentists hold similar esthetic evaluations or acceptability towards implant crown hole designs was rejected. Lay patients had a lower tolerance for venting holes than dentists. Crowns with 1 mm micro holes were more recommendable than crowns with regular abutment access holes from the point of view of satisfying patients’ esthetic needs.
format Online
Article
Text
id pubmed-8860758
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-88607582022-02-23 Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China Wen, Cai Jiang, Rong Zhang, Zhiqiang Lei, Bo Zhong, Yingquan Zhou, Huangjun Patient Prefer Adherence Original Research PURPOSE: Abutment access hole on dental implant crowns may facilitate crown retrieval and reduce cement overflow but present esthetic obstacle for patients. This study aimed to investigate the esthetic evaluation and acceptability of implant crowns with different hole designs from the perspective of patients and dentists. MATERIALS AND METHODS: Anterior and posterior implant zirconia crowns were fabricated into three types: no hole (NH), 1 mm micro hole (MH), and 2.5 mm regular hole (RH). The NH crown was set as the control, and the anterior and posterior crowns with MH and RH were evaluated. The subjects, who were recruited randomly, were comprised of lay patients (n=60) and professional dentists (n=30). All subjects were invited to evaluate the esthetic performance of MH and RH crowns on a Visual Analog Scale (VAS), rate them from 0 to 10, state their acceptability of these crowns, and label them as acceptable and unacceptable. RESULTS: The ANOVA analysis of the VAS esthetic evaluation showed that the size of the hole, the position of the teeth, and the professional background of the subject significantly and independently affected esthetic perception. Crowns with MH in the posterior position had higher esthetic scores and acceptability compared with crowns with RH in the anterior position, and dentists tended to show higher acceptance and better esthetic rating for crowns with holes compared with lay patients. CONCLUSION: The hypothesis that patients and dentists hold similar esthetic evaluations or acceptability towards implant crown hole designs was rejected. Lay patients had a lower tolerance for venting holes than dentists. Crowns with 1 mm micro holes were more recommendable than crowns with regular abutment access holes from the point of view of satisfying patients’ esthetic needs. Dove 2022-02-17 /pmc/articles/PMC8860758/ /pubmed/35210759 http://dx.doi.org/10.2147/PPA.S351143 Text en © 2022 Wen et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Wen, Cai
Jiang, Rong
Zhang, Zhiqiang
Lei, Bo
Zhong, Yingquan
Zhou, Huangjun
Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China
title Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China
title_full Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China
title_fullStr Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China
title_full_unstemmed Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China
title_short Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China
title_sort esthetic evaluation and acceptability of different hole designs on implant crowns from the perspective of patients and dentists in china
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860758/
https://www.ncbi.nlm.nih.gov/pubmed/35210759
http://dx.doi.org/10.2147/PPA.S351143
work_keys_str_mv AT wencai estheticevaluationandacceptabilityofdifferentholedesignsonimplantcrownsfromtheperspectiveofpatientsanddentistsinchina
AT jiangrong estheticevaluationandacceptabilityofdifferentholedesignsonimplantcrownsfromtheperspectiveofpatientsanddentistsinchina
AT zhangzhiqiang estheticevaluationandacceptabilityofdifferentholedesignsonimplantcrownsfromtheperspectiveofpatientsanddentistsinchina
AT leibo estheticevaluationandacceptabilityofdifferentholedesignsonimplantcrownsfromtheperspectiveofpatientsanddentistsinchina
AT zhongyingquan estheticevaluationandacceptabilityofdifferentholedesignsonimplantcrownsfromtheperspectiveofpatientsanddentistsinchina
AT zhouhuangjun estheticevaluationandacceptabilityofdifferentholedesignsonimplantcrownsfromtheperspectiveofpatientsanddentistsinchina