Cargando…

Diagnostic value of (18)F-FDG PET-CT in detecting malignant peripheral nerve sheath tumors among adult and pediatric neurofibromatosis type 1 patients

PURPOSE: Detecting malignant peripheral nerve sheath tumors (MPNSTs) remains difficult. (18)F-FDG PET-CT has been shown helpful, but ideal threshold values of semi-quantitative markers remain unclear, partially because of variation among scanners. Using EU-certified scanners diagnostic accuracy of i...

Descripción completa

Detalles Bibliográficos
Autores principales: Geitenbeek, Ritch T. J., Martin, Enrico, Graven, Laura H., Broen, Martijn P. G., Anten, Monique H. M. E., van der Pol, Jochem A. J., Verhoef, Cornelis, Taal, Walter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8860956/
https://www.ncbi.nlm.nih.gov/pubmed/35025020
http://dx.doi.org/10.1007/s11060-021-03936-y
Descripción
Sumario:PURPOSE: Detecting malignant peripheral nerve sheath tumors (MPNSTs) remains difficult. (18)F-FDG PET-CT has been shown helpful, but ideal threshold values of semi-quantitative markers remain unclear, partially because of variation among scanners. Using EU-certified scanners diagnostic accuracy of ideal and commonly used (18)F-FDG PET-CT thresholds were investigated and differences between adult and pediatric lesions were evaluated. METHODS: A retrospective cohort study was performed including patients from two hospitals with a clinical or radiological suspicion of MPNST between 2013 and 2019. Several markers were studied for ideal threshold values and differences among adults and children. A diagnostic algorithm was subsequently developed. RESULTS: Sixty patients were included (10 MPNSTs). Ideal threshold values were 5.8 for SUVmax (sensitivity 0.70, specificity 0.92), 5.0 for SUVpeak (sensitivity 0.70, specificity 0.97), 1.7 for TLmax (sensitivity 0.90, specificity 0.86), and 2.3 for TLmean (sensitivity 0.90, specificity 0.79). The standard TLmean threshold value of 2.0 yielded a sensitivity of 0.90 and specificity of 0.74, while the standard SUVmax threshold value of 3.5 yielded a sensitivity of 0.80 and specificity of 0.63. SUVmax and adjusted SUV for lean body mass (SUL) were lower in children, but tumor-to-liver ratios were similar in adult and pediatric lesions. Using TLmean > 2.0 or TLmean < 2.0 and SUVmax > 3.5, a sensitivity and specificity of 1.00 and 0.63 can be achieved. CONCLUSION: (18)F-FDG PET-CT offers adequate accuracy to detect MPNSTs. SUV values in pediatric MPNSTs may be lower, but tumor-to-liver ratios are not. By combining TLmean and SUVmax values, a 100% sensitivity can be achieved with acceptable specificity. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11060-021-03936-y.